These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 27669467)

  • 1. Addressing bias in polyp size measurement.
    Hassan C; Repici A; Rex DK
    Endoscopy; 2016 Oct; 48(10):881-3. PubMed ID: 27669467
    [No Abstract]   [Full Text] [Related]  

  • 2. Terminal digit preference biases polyp size measurements at endoscopy, computed tomographic colonography, and histopathology.
    Plumb AA; Nickerson C; Wooldrage K; Bassett P; Taylor SA; Altman D; Atkin W; Halligan S
    Endoscopy; 2016 Oct; 48(10):899-908. PubMed ID: 27441685
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement Bias of Polyp Size at Colonoscopy.
    Sakata S; Klein K; Stevenson ARL; Hewett DG
    Dis Colon Rectum; 2017 Sep; 60(9):987-991. PubMed ID: 28796738
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement bias of colorectal polyp size: Analysis of the Japan Endoscopy Database.
    Utsumi T; Horimatsu T; Seno H
    Dig Endosc; 2019 Sep; 31(5):589. PubMed ID: 31120583
    [No Abstract]   [Full Text] [Related]  

  • 5. Debate: small (6-9 mm) and diminutive (1-5 mm) polyps noted on CTC: how should they be managed?
    Lieberman D
    Gastrointest Endosc Clin N Am; 2010 Apr; 20(2):239-43. PubMed ID: 20451813
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Debate: diminutive polyps noted at CT colonography need not be reported.
    Lenhart DK; Zalis ME
    Gastrointest Endosc Clin N Am; 2010 Apr; 20(2):227-37. PubMed ID: 20451812
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Endoscopic tattooing of colorectal neoplasms and laparoscopic surgery: technical aspects and recommendations].
    Bashankaev BN; Shishin KV; Veselov VV; Mitrakov AA; Velikanov EV
    Khirurgiia (Mosk); 2017; (10):77-81. PubMed ID: 29076487
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Colonoscopic surveillance: quality, guidelines and effectiveness.
    Chittleborough TJ; Kong JC; Guerra GR; Ramsay R; Heriot AG
    ANZ J Surg; 2018 Jan; 88(1-2):32-38. PubMed ID: 28803452
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cold Snare Polypectomy: Techniques and Applications.
    Keswani RN
    Clin Gastroenterol Hepatol; 2020 Jan; 18(1):42-44. PubMed ID: 31782991
    [No Abstract]   [Full Text] [Related]  

  • 10. Assessment of colorectal adenomatous polyp size measured during pathological examination highlights the importance of accuracy.
    Hayes SJ
    Gastrointest Endosc; 2009 Sep; 70(3):540-1. PubMed ID: 19555943
    [No Abstract]   [Full Text] [Related]  

  • 11. [Colonoscopy for early detection and prevention of colorectal cancer].
    Niv Y
    Harefuah; 2010 Aug; 149(8):535-6, 549. PubMed ID: 21341435
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of polyp size at colonoscopy: a proof-of-concept simulation study to address technology bias.
    Sakata S; McIvor F; Klein K; Stevenson ARL; Hewett DG
    Gut; 2018 Feb; 67(2):206-208. PubMed ID: 27697826
    [No Abstract]   [Full Text] [Related]  

  • 13. Endoscopic mis-sizing of polyps changes colorectal cancer surveillance recommendations.
    Eichenseer PJ; Dhanekula R; Jakate S; Mobarhan S; Melson JE
    Dis Colon Rectum; 2013 Mar; 56(3):315-21. PubMed ID: 23392145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Portrait of a polyp: the CTC dilemma.
    Iafrate F; Hassan C; Pickhardt PJ; Pichi A; Stagnitti A; Zullo A; Di Giulio E; Laghi A
    Abdom Imaging; 2010 Feb; 35(1):49-54. PubMed ID: 19109729
    [No Abstract]   [Full Text] [Related]  

  • 15. [The diagnosis of colorectal polyp by endoscopic ultrasonography].
    Takada H; Yoshimoto K; Hijikata A; Sakai Y
    Nihon Rinsho; 1991 Dec; 49(12):61-4. PubMed ID: 1787586
    [No Abstract]   [Full Text] [Related]  

  • 16. Endoscopy-related factors contributing to postcolonoscopy colorectal cancers.
    Rustagi T; Anderson JC
    Gastroenterology; 2014 Jan; 146(1):311-3; discussion 313. PubMed ID: 24275243
    [No Abstract]   [Full Text] [Related]  

  • 17. Update on colorectal polyps: management and follow-up surveillance.
    Bond JH
    Endoscopy; 2003 Aug; 35(8):S35-40. PubMed ID: 12929052
    [No Abstract]   [Full Text] [Related]  

  • 18. [Serrated polyps is a hidden but common cause of colorectal cancer].
    Thorlacius H; Ljungberg O; Toth E
    Lakartidningen; 2015 Aug; 112():. PubMed ID: 26284883
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polyp measurement reliability, accuracy, and discrepancy: optical colonoscopy versus CT colonography with pig colonic specimens.
    Park SH; Choi EK; Lee SS; Byeon JS; Jo JY; Kim YH; Lee KH; Ha HK; Han JK
    Radiology; 2007 Jul; 244(1):157-64. PubMed ID: 17507724
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Is surveillance colonoscopy necessary for all patients with bowel polyps?
    Robbins EC; Wooldrage K; Cross AJ
    BMJ; 2020 May; 369():m1706. PubMed ID: 32414779
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.