131 related articles for article (PubMed ID: 27670144)
1. Evaluation of renal oxygenation change under the influence of carbogen breathing using a dynamic R
Wang C; Zhao K; Zhang R; Jiang L; Wang R; Zhang X; Wang H; Jin L; Zhang J; Wang X; Fang J
NMR Biomed; 2016 Nov; 29(11):1601-1607. PubMed ID: 27670144
[TBL] [Abstract][Full Text] [Related]
2. Noninvasive measurement of renal oxygen extraction fraction under the influence of respiratory challenge.
Wang C; Zhang R; Wang R; Jiang L; Zhang X; Wang H; Zhao K; Jin L; Zhang J; Wang X; Fang J
J Magn Reson Imaging; 2016 Jul; 44(1):230-7. PubMed ID: 26800848
[TBL] [Abstract][Full Text] [Related]
3. Simultaneous dynamic R
Wang C; Zhang R; Zhang X; Wang H; Zhao K; Jin L; Zhang J; Wang X; Fang J
Magn Reson Med; 2017 Feb; 77(2):766-773. PubMed ID: 26946046
[TBL] [Abstract][Full Text] [Related]
4. Blood oxygen level-dependent magnetic resonance imaging of the kidneys: influence of spatial resolution on the apparent R2* transverse relaxation rate of renal tissue.
Rossi C; Sharma P; Pazahr S; Alkadhi H; Nanz D; Boss A
Invest Radiol; 2013 Sep; 48(9):671-7. PubMed ID: 23571833
[TBL] [Abstract][Full Text] [Related]
5. Dynamic oxygen challenge evaluated by NMR T1 and T2*--insights into tumor oxygenation.
Zhao D; Pacheco-Torres J; Hallac RR; White D; Peschke P; Cerdán S; Mason RP
NMR Biomed; 2015 Aug; 28(8):937-947. PubMed ID: 26058575
[TBL] [Abstract][Full Text] [Related]
6. Quantitative BOLD response of the renal medulla to hyperoxic challenge at 1.5 T and 3.0 T.
Donati OF; Nanz D; Serra AL; Boss A
NMR Biomed; 2012 Oct; 25(10):1133-8. PubMed ID: 22290729
[TBL] [Abstract][Full Text] [Related]
7. BOLD quantified renal pO2 is sensitive to pharmacological challenges in rats.
Thacker J; Zhang JL; Franklin T; Prasad P
Magn Reson Med; 2017 Jul; 78(1):297-302. PubMed ID: 27501515
[TBL] [Abstract][Full Text] [Related]
8. Influence of oxygen and carbogen breathing on renal oxygenation measured by T2*-weighted imaging at 3.0 T.
Boss A; Martirosian P; Jehs MC; Dietz K; Alber M; Rossi C; Claussen CD; Schick F
NMR Biomed; 2009 Jul; 22(6):638-45. PubMed ID: 19306339
[TBL] [Abstract][Full Text] [Related]
9. Comparison of normal tissue R1 and R*2 modulation by oxygen and carbogen.
O'Connor JP; Naish JH; Jackson A; Waterton JC; Watson Y; Cheung S; Buckley DL; McGrath DM; Buonaccorsi GA; Mills SJ; Roberts C; Jayson GC; Parker GJ
Magn Reson Med; 2009 Jan; 61(1):75-83. PubMed ID: 19097212
[TBL] [Abstract][Full Text] [Related]
10. Non-invasive monitoring of renal oxygenation using BOLD-MRI: a reproducibility study.
Simon-Zoula SC; Hofmann L; Giger A; Vogt B; Vock P; Frey FJ; Boesch C
NMR Biomed; 2006 Feb; 19(1):84-9. PubMed ID: 16411163
[TBL] [Abstract][Full Text] [Related]
11. R1 and R2 * changes in the human placenta in response to maternal oxygen challenge.
Huen I; Morris DM; Wright C; Parker GJ; Sibley CP; Johnstone ED; Naish JH
Magn Reson Med; 2013 Nov; 70(5):1427-33. PubMed ID: 23280967
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of renal oxygenation in rat by using R2' at 3-T magnetic resonance: initial observation.
Yang X; Cao J; Wang X; Li X; Xu Y; Jiang X
Acad Radiol; 2008 Jul; 15(7):912-8. PubMed ID: 18572128
[TBL] [Abstract][Full Text] [Related]
13. Monitoring Tumor Response to Carbogen Breathing by Oxygen-Sensitive Magnetic Resonance Parameters to Predict the Outcome of Radiation Therapy: A Preclinical Study.
Cao-Pham TT; Tran LB; Colliez F; Joudiou N; El Bachiri S; Grégoire V; Levêque P; Gallez B; Jordan BF
Int J Radiat Oncol Biol Phys; 2016 Sep; 96(1):149-60. PubMed ID: 27511852
[TBL] [Abstract][Full Text] [Related]
14. Dynamic and simultaneous MR measurement of R1 and R2* changes during respiratory challenges for the assessment of blood and tissue oxygenation.
Remmele S; Sprinkart AM; Müller A; Träber F; von Lehe M; Gieseke J; Flacke S; Willinek WA; Schild HH; Sénégas J; Keupp J; Mürtz P
Magn Reson Med; 2013 Jul; 70(1):136-46. PubMed ID: 22926895
[TBL] [Abstract][Full Text] [Related]
15. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain.
Sedlacik J; Reitz M; Bolar DS; Adalsteinsson E; Schmidt NO; Fiehler J
Z Med Phys; 2015 Mar; 25(1):77-85. PubMed ID: 24636672
[TBL] [Abstract][Full Text] [Related]
16. Feasibility of noninvasive quantitative measurements of intrarenal R(2) ' in humans using an asymmetric spin echo echo planar imaging sequence.
Zhang X; Zhang Y; Yang X; Wang X; An H; Zhang J; Fang J
NMR Biomed; 2013 Jan; 26(1):91-7. PubMed ID: 22684799
[TBL] [Abstract][Full Text] [Related]
17. Simultaneous measurement of tissue oxygen level-dependent (TOLD) and blood oxygenation level-dependent (BOLD) effects in abdominal tissue oxygenation level studies.
Ding Y; Mason RP; McColl RW; Yuan Q; Hallac RR; Sims RD; Weatherall PT
J Magn Reson Imaging; 2013 Nov; 38(5):1230-6. PubMed ID: 23749420
[TBL] [Abstract][Full Text] [Related]
18. Benchmarking transverse spin relaxation based oxygenation measurements in the brain during hypercapnia and hypoxia.
Ni WW; Christen T; Zaharchuk G
J Magn Reson Imaging; 2017 Sep; 46(3):704-714. PubMed ID: 28306210
[TBL] [Abstract][Full Text] [Related]
19. Renal blood oxygenation level-dependent imaging: contribution of R2 to R2* values.
Vivier PH; Storey P; Chandarana H; Yamamoto A; Tantillo K; Khan U; Zhang JL; Sigmund EE; Rusinek H; Babb JS; Bubenheim M; Lee VS
Invest Radiol; 2013 Jul; 48(7):501-8. PubMed ID: 23385400
[TBL] [Abstract][Full Text] [Related]
20. Feasibility and reproducibility of BOLD and TOLD measurements in the liver with oxygen and carbogen gas challenge in healthy volunteers and patients with hepatocellular carcinoma.
Bane O; Besa C; Wagner M; Oesingmann N; Zhu H; Fiel MI; Taouli B
J Magn Reson Imaging; 2016 Apr; 43(4):866-76. PubMed ID: 26417669
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]