These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 27670395)

  • 21. Role of the hemodialysis vascular access type in inflammation status and monocyte activation.
    Colì L; Donati G; Cappuccilli ML; Cianciolo G; Comai G; Cuna V; Carretta E; La Manna G; Stefoni S
    Int J Artif Organs; 2011 Jun; 34(6):481-8. PubMed ID: 21725929
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reduction in beta2-microglobulin with super-flux versus high-flux dialysis membranes: results of a 6-week, randomized, double-blind, crossover trial.
    Pellicano R; Polkinghorne KR; Kerr PG
    Am J Kidney Dis; 2008 Jul; 52(1):93-101. PubMed ID: 18423807
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Acute and chronic influence of hemodialysis according to the membrane used on phagocytic function of neutrophils and monocytes and pro-inflammatory cytokines production in chronic renal failure patients.
    Muniz-Junqueira MI; Braga Lopes C; Magalhães CA; Schleicher CC; Veiga JP
    Life Sci; 2005 Nov; 77(25):3141-55. PubMed ID: 16005905
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Easy production of sterile, pyrogen-free dialysate.
    Erley CM; von Herrath D; Hartenstein-Koch K; Kutschera D; Amir-Moazami B; Schaefer K
    ASAIO Trans; 1988; 34(3):205-7. PubMed ID: 3196509
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease.
    MacLeod A; Daly C; Khan I; Vale L; Campbell M; Wallace S; Cody J; Donaldson C; Grant A
    Cochrane Database Syst Rev; 2001; (3):CD003234. PubMed ID: 11687058
    [TBL] [Abstract][Full Text] [Related]  

  • 26. High-flux and low-flux dialysis membranes and levels of intercellular adhesion molecule-1 and vascular cell adhesion molecule-1 in children with chronic kidney failure.
    Sawires HK; Mohamed WA; Schaalan MF
    Iran J Kidney Dis; 2012 Sep; 6(5):366-72. PubMed ID: 22976263
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Chronic inflammation in hemodialysis: the role of contaminated dialysate.
    Lonnemann G
    Blood Purif; 2000; 18(3):214-23. PubMed ID: 10859424
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Circulatory mitochondrial DNA is a pro-inflammatory agent in maintenance hemodialysis patients.
    Cao H; Ye H; Sun Z; Shen X; Song Z; Wu X; He W; Dai C; Yang J
    PLoS One; 2014; 9(12):e113179. PubMed ID: 25485699
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Changes in Mac-1 and CD14 expression on monocytes and serum soluble CD14 level during push/pull hemodiafiltration.
    Kawabata K; Nakai S; Miwa M; Sugiura T; Otsuka Y; Shinzato T; Hiki Y; Tomimatsu I; Ushida Y; Hosono F; Maeda K
    Nephron; 2002 Mar; 90(3):273-81. PubMed ID: 11867948
    [TBL] [Abstract][Full Text] [Related]  

  • 30. High cut-off dialysis mitigates pro-calcific effects of plasma on vascular progenitor cells.
    Schaub T; Janke D; Zickler D; Lange C; Girndt M; Schindler R; Dragun D; Hegner B
    Sci Rep; 2021 Jan; 11(1):1144. PubMed ID: 33441772
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ex vivo flow cytometry determination of intracytoplasmic expression of IL-2, IL-6, IFN-gamma, and TNF-alpha in monocytes and T lymphocytes, in chronic hemodialysis patients.
    Rostaing L; Peres C; Tkaczuk J; Charlet JP; Bories P; Durand D; Ohayon E; de Préval C; Abbal M
    Am J Nephrol; 2000; 20(1):18-26. PubMed ID: 10644863
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Assessment of subjective and hemodynamic tolerance of different high- and low-flux dialysis membranes in patients undergoing chronic intermittent hemodialysis: a randomized controlled trial.
    Bianchi G; Salvadé V; Lucchini B; Schätti-Stählin S; Salvadé I; Burnier M; Gabutti L
    Hemodial Int; 2014 Oct; 18(4):825-34. PubMed ID: 24865782
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Monocytes from dialysis patients exhibit characteristics of senescent cells: does it really mean inflammation?
    Carracedo J; Ramirez R; Soriano S; Alvarez de Lara MA; Rodriguez M; Martin-Malo A; Aljama P
    Contrib Nephrol; 2005; 149():208-218. PubMed ID: 15876845
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Acute effect of hemodialysis on serum levels of the proinflammatory cytokines.
    Tarakçioğlu M; Erbağci AB; Usalan C; Deveci R; Kocabaş R
    Mediators Inflamm; 2003 Feb; 12(1):15-9. PubMed ID: 12745544
    [TBL] [Abstract][Full Text] [Related]  

  • 35. High-calcium dialysate: a factor associated with inflammation, malnutrition and mortality in non-diabetic maintenance haemodialysis patients.
    Hsu CW; Lin JL; Lin-Tan DT; Yen TH; Chen KH; Huang WH; Ho TC; Huang YL
    Nephrology (Carlton); 2010 Apr; 15(3):313-20. PubMed ID: 20470300
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Conventional versus ultrapure dialysate for lowering serum lipoprotein(a) levels in patients on long-term hemodialysis: a randomized trial.
    Tao J; Sun Y; Li X; Li H; Liu S; Wen Y; Duan L; Li Y; Li X
    Int J Artif Organs; 2010 May; 33(5):290-6. PubMed ID: 20593350
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Removal of Cell-Activating Substances Using Dialyzers With Various Permeability Profiles.
    Latosinska A; Hulko M; Speidel R; Mischak H; Storr M; Krause B
    Artif Organs; 2018 Jan; 42(1):78-87. PubMed ID: 28744941
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cellulose membranes are more effective in holding back vital proteins and exhibit less interaction with plasma proteins during hemodialysis.
    Pešić I; Müller GA; Baumann C; Dihazi GH; Koziolek MJ; Eltoweissy M; Bramlage C; Asif AR; Dihazi H
    Biochim Biophys Acta; 2013 Apr; 1834(4):754-62. PubMed ID: 23369790
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Immunomodulatory Device Promotes a Shift of Circulating Monocytes to a Less Inflammatory Phenotype in Chronic Hemodialysis Patients.
    Szamosfalvi B; Westover A; Buffington D; Yevzlin A; Humes HD
    ASAIO J; 2016; 62(5):623-30. PubMed ID: 27258222
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A pilot, randomized, double-blind, cross-over study of high cut-off versus high-flux dialysis membranes.
    Lee D; Haase M; Haase-Fielitz A; Paizis K; Goehl H; Bellomo R
    Blood Purif; 2009; 28(4):365-72. PubMed ID: 19729908
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.