BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

896 related articles for article (PubMed ID: 27672012)

  • 1. Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs.
    Sandiford NA; Garbuz DS; Masri BA; Duncan CP
    Clin Orthop Relat Res; 2017 Jan; 475(1):186-192. PubMed ID: 27672012
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High Survivorship With Cementless Stems and Cortical Strut Allografts for Large Femoral Bone Defects in Revision THA.
    Kim YH; Park JW; Kim JS; Rastogi D
    Clin Orthop Relat Res; 2015 Sep; 473(9):2990-3000. PubMed ID: 26013152
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is There a Benefit to Modularity in 'Simpler' Femoral Revisions?
    Huddleston JI; Tetreault MW; Yu M; Bedair H; Hansen VJ; Choi HR; Goodman SB; Sporer SM; Della Valle CJ
    Clin Orthop Relat Res; 2016 Feb; 474(2):415-20. PubMed ID: 26245164
    [TBL] [Abstract][Full Text] [Related]  

  • 4. What Is the Difference Between Modular and Nonmodular Tapered Fluted Titanium Stems in Revision Total Hip Arthroplasty.
    Huang Y; Zhou Y; Shao H; Gu J; Tang H; Tang Q
    J Arthroplasty; 2017 Oct; 32(10):3108-3113. PubMed ID: 28602532
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Short-term outcomes with the REDAPT monolithic, tapered, fluted, grit-blasted, forged titanium revision femoral stem.
    Gabor JA; Padilla JA; Feng JE; Schnaser E; Lutes WB; Park KJ; Incavo S; Vigdorchik J; Schwarzkopf R
    Bone Joint J; 2020 Feb; 102-B(2):191-197. PubMed ID: 32009430
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiographic and Clinical Outcomes of Modular Tapered Fluted Stems for Femoral Revision for Paprosky III and IV Femoral Defects or Vancouver B2 and B3 Femoral Fractures.
    Otero JE; Martin JR; Rowe TM; Odum SM; Mason JB
    J Arthroplasty; 2020 Apr; 35(4):1069-1073. PubMed ID: 31870582
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component.
    Amanatullah DF; Howard JL; Siman H; Trousdale RT; Mabry TM; Berry DJ
    Bone Joint J; 2015 Mar; 97-B(3):312-7. PubMed ID: 25737513
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Revision Total Hip Arthroplasty With a Monoblock Splined Tapered Grit-Blasted Titanium Stem.
    Hellman MD; Kearns SM; Bohl DD; Haughom BD; Levine BR
    J Arthroplasty; 2017 Dec; 32(12):3698-3703. PubMed ID: 28803814
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Can a Conical Implant Successfully Address Complex Anatomy in Primary THA? Radiographs and Hip Scores at Early Followup.
    Zhang Q; Goodman SB; Maloney WJ; Huddleston JI
    Clin Orthop Relat Res; 2016 Feb; 474(2):459-64. PubMed ID: 26245165
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modular Fluted Tapered Stems in Aseptic Revision Total Hip Arthroplasty.
    Abdel MP; Cottino U; Larson DR; Hanssen AD; Lewallen DG; Berry DJ
    J Bone Joint Surg Am; 2017 May; 99(10):873-881. PubMed ID: 28509828
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High survival of modular tapered stems for proximal femoral bone defects at 5 to 10 years followup.
    Van Houwelingen AP; Duncan CP; Masri BA; Greidanus NV; Garbuz DS
    Clin Orthop Relat Res; 2013 Feb; 471(2):454-62. PubMed ID: 22948527
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term results of femoral revision with the Wagner Self-Locking stem.
    Regis D; Sandri A; Bonetti I
    Surg Technol Int; 2013 Sep; 23():243-50. PubMed ID: 24081844
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of modular and nonmodular tapered fluted titanium stems in femoral revision hip arthroplasty: a minimum 6-year follow-up study.
    Feng S; Zhang Y; Bao YH; Yang Z; Zha GC; Chen XY
    Sci Rep; 2020 Aug; 10(1):13692. PubMed ID: 32792539
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Femoral revision hip arthroplasty: a comparison of two stem designs.
    Richards CJ; Duncan CP; Masri BA; Garbuz DS
    Clin Orthop Relat Res; 2010 Feb; 468(2):491-6. PubMed ID: 19847578
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Patterns of osseointegration and remodeling in femoral revision with bone loss using modular, tapered, fluted, titanium stems.
    Rodriguez JA; Deshmukh AJ; Klauser WU; Rasquinha VJ; Lubinus P; Ranawat CS
    J Arthroplasty; 2011 Dec; 26(8):1409-17.e1. PubMed ID: 21855273
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modular tapered implants for severe femoral bone loss in THA: reliable osseointegration but frequent complications.
    Brown NM; Tetreault M; Cipriano CA; Della Valle CJ; Paprosky W; Sporer S
    Clin Orthop Relat Res; 2015 Feb; 473(2):555-60. PubMed ID: 25053289
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Complex revision total hip arthroplasty with modular stems at a mean of 14 years.
    McCarthy JC; Lee JA
    Clin Orthop Relat Res; 2007 Dec; 465():166-9. PubMed ID: 17891035
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tapered fluted titanium stems in the management of Vancouver B2 and B3 periprosthetic femoral fractures.
    Munro JT; Garbuz DS; Masri BA; Duncan CP
    Clin Orthop Relat Res; 2014 Feb; 472(2):590-8. PubMed ID: 23719963
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.
    Watts CD; Abdel MP; Lewallen DG; Berry DJ; Hanssen AD
    Clin Orthop Relat Res; 2015 Jun; 473(6):2045-53. PubMed ID: 25502478
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Midterm results of titanium conical Wagner stem with challenging femoral anatomy: Survivorship and unique bone remodeling.
    Shahin M; Massé V; Belzile É; Bédard L; Angers M; Vendittoli PA
    Orthop Traumatol Surg Res; 2023 Feb; 109(1):103242. PubMed ID: 35158103
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 45.