1. Gadopentetate but not gadobutrol accumulates in the dentate nucleus of multiple sclerosis patients.
Schlemm L; Chien C; Bellmann-Strobl J; Dörr J; Wuerfel J; Brandt AU; Paul F; Scheel M
Mult Scler; 2017 Jun; 23(7):963-972. PubMed ID: 27679460
[TBL] [Abstract][Full Text] [Related]
2. Progressive T1 Shortening of the Dentate Nucleus in Patients With Multiple Sclerosis: Result of Multiple Administrations of Linear Gadolinium Contrast Agents Versus Intrinsic Disease.
Malhotra A; LeSar B; Wu X; Durand D; Das N; Anzai Y; Sanelli P
AJR Am J Roentgenol; 2018 Nov; 211(5):1099-1105. PubMed ID: 30160975
[TBL] [Abstract][Full Text] [Related]
3. Signal Change in the Dentate Nucleus on T1-Weighted MR Images After Multiple Administrations of Gadopentetate Dimeglumine Versus Gadobutrol.
Cao Y; Huang DQ; Shih G; Prince MR
AJR Am J Roentgenol; 2016 Feb; 206(2):414-9. PubMed ID: 26700156
[TBL] [Abstract][Full Text] [Related]
4. Gadolinium deposition within the paediatric brain: no increased intrinsic T1-weighted signal intensity within the dentate nucleus following the administration of a minimum of four doses of the macrocyclic agent gadobutrol.
Young JR; Qiao J; Orosz I; Salamon N; Franke MA; Kim HJ; Pope WB
Eur Radiol; 2018 Nov; 28(11):4882-4889. PubMed ID: 29744642
[TBL] [Abstract][Full Text] [Related]
5. Intraindividual Analysis of Signal Intensity Changes in the Dentate Nucleus After Consecutive Serial Applications of Linear and Macrocyclic Gadolinium-Based Contrast Agents.
Radbruch A; Weberling LD; Kieslich PJ; Hepp J; Kickingereder P; Wick W; Schlemmer HP; Bendszus M
Invest Radiol; 2016 Nov; 51(11):683-690. PubMed ID: 27495187
[TBL] [Abstract][Full Text] [Related]
6. Gadolinium Accumulation in the Deep Cerebellar Nuclei and Globus Pallidus After Exposure to Linear but Not Macrocyclic Gadolinium-Based Contrast Agents in a Retrospective Pig Study With High Similarity to Clinical Conditions.
Boyken J; Frenzel T; Lohrke J; Jost G; Pietsch H
Invest Radiol; 2018 May; 53(5):278-285. PubMed ID: 29319556
[TBL] [Abstract][Full Text] [Related]
7. Comparison of Unenhanced T1-Weighted Signal Intensities Within the Dentate Nucleus and the Globus Pallidus After Serial Applications of Gadopentetate Dimeglumine Versus Gadobutrol in a Pediatric Population.
Renz DM; Kümpel S; Böttcher J; Pfeil A; Streitparth F; Waginger M; Reichenbach JR; Teichgräber UK; Mentzel HJ
Invest Radiol; 2018 Feb; 53(2):119-127. PubMed ID: 28976476
[TBL] [Abstract][Full Text] [Related]
8. Dentate Nucleus Signal Intensity Decrease on T1-weighted MR Images after Switching from Gadopentetate Dimeglumine to Gadobutrol.
Behzadi AH; Farooq Z; Zhao Y; Shih G; Prince MR
Radiology; 2018 Jun; 287(3):816-823. PubMed ID: 29533723
[TBL] [Abstract][Full Text] [Related]
9. Effects of serial macrocyclic-based contrast materials gadoterate meglumine and gadobutrol administrations on gadolinium-related dentate nuclei signal increases in unenhanced T1-weighted brain: a retrospective study in 158 multiple sclerosis (MS) patients.
Splendiani A; Perri M; Marsecano C; Vellucci V; Michelini G; Barile A; Di Cesare E
Radiol Med; 2018 Feb; 123(2):125-134. PubMed ID: 28952018
[TBL] [Abstract][Full Text] [Related]
10. Histology and Gadolinium Distribution in the Rodent Brain After the Administration of Cumulative High Doses of Linear and Macrocyclic Gadolinium-Based Contrast Agents.
Lohrke J; Frisk AL; Frenzel T; Schöckel L; Rosenbruch M; Jost G; Lenhard DC; Sieber MA; Nischwitz V; Küppers A; Pietsch H
Invest Radiol; 2017 Jun; 52(6):324-333. PubMed ID: 28323657
[TBL] [Abstract][Full Text] [Related]
11. Weekly enhanced T1-weighted MRI with Gadobutrol injections in MS patients: Is there a signal intensity increase in the dentate nucleus and the globus pallidus?
Jaulent P; Hannoun S; Kocevar G; Rollot F; Durand-Dubief F; Vukusic S; Brisset JC; Sappey-Marinier D; Cotton F
Eur J Radiol; 2018 Aug; 105():204-208. PubMed ID: 30017281
[TBL] [Abstract][Full Text] [Related]
12. Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: correlation with cumulative dose of a macrocyclic gadolinium-based contrast agent, gadobutrol.
Stojanov DA; Aracki-Trenkic A; Vojinovic S; Benedeto-Stojanov D; Ljubisavljevic S
Eur Radiol; 2016 Mar; 26(3):807-15. PubMed ID: 26105022
[TBL] [Abstract][Full Text] [Related]
13. Gadolinium deposition in the brain: association with various GBCAs using a generalized additive model.
Bae S; Lee HJ; Han K; Park YW; Choi YS; Ahn SS; Kim J; Lee SK
Eur Radiol; 2017 Aug; 27(8):3353-3361. PubMed ID: 28083696
[TBL] [Abstract][Full Text] [Related]
14. Dentate-nucleus gadolinium deposition on magnetic resonance imaging: ultrasonographic and clinical correlates in multiple sclerosis patients.
Kühn I; Maschke H; Großmann A; Hauenstein K; Weber MA; Zettl UK; Storch A; Walter U
Neurol Sci; 2022 Apr; 43(4):2631-2639. PubMed ID: 34735650
[TBL] [Abstract][Full Text] [Related]
15. High Signal Intensity in Dentate Nucleus on Unenhanced T1-weighted MR Images: Association with Linear versus Macrocyclic Gadolinium Chelate Administration.
Kanda T; Osawa M; Oba H; Toyoda K; Kotoku J; Haruyama T; Takeshita K; Furui S
Radiology; 2015 Jun; 275(3):803-9. PubMed ID: 25633504
[TBL] [Abstract][Full Text] [Related]
16. Pediatric Brain: Gadolinium Deposition in Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images Is Dependent on the Type of Contrast Agent.
Ryu YJ; Choi YH; Cheon JE; Lee WJ; Park S; Park JE; Kim WS; Kim IO
Invest Radiol; 2018 Apr; 53(4):246-255. PubMed ID: 29300210
[TBL] [Abstract][Full Text] [Related]
17. Changes in signal intensity in the dentate nucleus at unenhanced T1-weighted magnetic resonance imaging depending on class of previously used gadolinium-based contrast agent.
Kasper E; Schemuth HP; Horry S; Kinner S
Pediatr Radiol; 2018 May; 48(5):686-693. PubMed ID: 29417165
[TBL] [Abstract][Full Text] [Related]
18. Gadolinium Presence in the Brain After Administration of the Liver-Specific Gadolinium-Based Contrast Agent Gadoxetate: A Systematic Comparison to Multipurpose Agents in Rats.
Jost G; Frenzel T; Boyken J; Schoeckel L; Pietsch H
Invest Radiol; 2019 Aug; 54(8):468-474. PubMed ID: 30932931
[TBL] [Abstract][Full Text] [Related]
19. Dentate nucleus signal intensity changes on T1-weighted MRI after repeated administrations of linear and macrocyclic gadolinium-based contrast agents: a pediatric intraindividual case-control study.
Ozturk K; Nascene D
Acta Radiol; 2022 Jul; 63(7):914-922. PubMed ID: 34018821
[TBL] [Abstract][Full Text] [Related]
20. Linear Gadolinium-Based Contrast Agents Are Associated With Brain Gadolinium Retention in Healthy Rats.
Robert P; Violas X; Grand S; Lehericy S; Idée JM; Ballet S; Corot C
Invest Radiol; 2016 Feb; 51(2):73-82. PubMed ID: 26606549
[TBL] [Abstract][Full Text] [Related]