These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

71 related articles for article (PubMed ID: 2767964)

  • 1. An analysis of the changes in the surfaces of metallic femoral components in hip prostheses. A study of 60 prostheses removed after 1-20 years.
    Pazzaglia UE; Pedrotti L; Ramella R; Zatti G
    Ital J Orthop Traumatol; 1989 Jun; 15(2):221-9. PubMed ID: 2767964
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
    Davidson JA
    Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Wear induced by motion between bone and titanium or cobalt-chrome alloys.
    Bischoff UW; Freeman MA; Smith D; Tuke MA; Gregson PJ
    J Bone Joint Surg Br; 1994 Sep; 76(5):713-6. PubMed ID: 8083256
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Biodeterioration and corrosion of metallic implants and prostheses].
    López GD
    Medicina (B Aires); 1993; 53(3):260-74. PubMed ID: 8114635
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Particulate metallic debris in cemented total hip arthroplasty.
    Salvati EA; Betts F; Doty SB
    Clin Orthop Relat Res; 1993 Aug; (293):160-73. PubMed ID: 8339477
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements.
    Hallab NJ; Messina C; Skipor A; Jacobs JJ
    J Orthop Res; 2004 Mar; 22(2):250-9. PubMed ID: 15013082
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?
    Serhan H; Slivka M; Albert T; Kwak SD
    Spine J; 2004; 4(4):379-87. PubMed ID: 15246296
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multiphase MP35N alloy for medical implants.
    Younkin CN
    J Biomed Mater Res; 1974; 8(3):219-26. PubMed ID: 4455699
    [No Abstract]   [Full Text] [Related]  

  • 10. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling.
    Gilbert JL; Buckley CA; Jacobs JJ
    J Biomed Mater Res; 1993 Dec; 27(12):1533-44. PubMed ID: 8113241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [A study of the potential corrosion of the madreporic prostheses compared with plane surface prostheses (author's transl)].
    Lord G; Bancel M; Bancel P
    Rev Chir Orthop Reparatrice Appar Mot; 1979 Sep; 65(6):317-26. PubMed ID: 161636
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corrosion and wear at the modular interface of uncemented femoral stems.
    Cook SD; Barrack RL; Clemow AJ
    J Bone Joint Surg Br; 1994 Jan; 76(1):68-72. PubMed ID: 8300685
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wear and corrosion of modular interfaces in total hip replacements.
    Cook SD; Barrack RL; Baffes GC; Clemow AJ; Serekian P; Dong N; Kester MA
    Clin Orthop Relat Res; 1994 Jan; (298):80-8. PubMed ID: 8119000
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An analysis of the head-neck taper interface in retrieved hip prostheses.
    Lieberman JR; Rimnac CM; Garvin KL; Klein RW; Salvati EA
    Clin Orthop Relat Res; 1994 Mar; (300):162-7. PubMed ID: 8131330
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Extensive porosity at the cement-femoral prosthesis interface: a preliminary study.
    James SP; Schmalzried TP; McGarry FJ; Harris WH
    J Biomed Mater Res; 1993 Jan; 27(1):71-8. PubMed ID: 8421001
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the effect of the femoral articular surface material on the wear of a metal-backed patellar component.
    Milliano MT; Whiteside LA; Kaiser AD; Zwirkoski PA
    Clin Orthop Relat Res; 1993 Feb; (287):178-86. PubMed ID: 8448938
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metallic wear debris in dual modular hip arthroplasty.
    Baleani M; Viceconti M; Walchholz K; Toni A
    Chir Organi Mov; 1997; 82(3):231-8. PubMed ID: 9494240
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance analysis of total hip prostheses: some particular metallurgical observations.
    Ducheyne P; De Meester P; Aernoudt E
    J Biomed Mater Res; 1980 Jan; 14(1):31-40. PubMed ID: 7358739
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [10-year actuarial analysis of a cohort of 156 total hip prostheses of a cemented polished aluminum/polyethylene alloy].
    Le Mouel S; Allain J; Goutallier D
    Rev Chir Orthop Reparatrice Appar Mot; 1998 Jul; 84(4):338-45. PubMed ID: 9775034
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Wear characteristics of different metal-polyethylene beating surfaces. An experimental study of a new model of knee prosthesis].
    Farizon F; Aurelle JL; Rieu J; Bousquet G
    Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(6):522-8. PubMed ID: 9122523
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.