207 related articles for article (PubMed ID: 27683272)
1. Plasma sodium measurements by direct ion selective methods in laboratory and point of care may not be clinically interchangeable.
Weld BA; Morgan TJ; Presneill JJ; Weier S; Cowley D
J Clin Monit Comput; 2017 Oct; 31(5):1103-1109. PubMed ID: 27683272
[TBL] [Abstract][Full Text] [Related]
2. Disagreement between ion selective electrode direct and indirect sodium measurements: estimation of the problem in a tertiary referral hospital.
Dimeski G; Morgan TJ; Presneill JJ; Venkatesh B
J Crit Care; 2012 Jun; 27(3):326.e9-16. PubMed ID: 22227082
[TBL] [Abstract][Full Text] [Related]
3. Prevalence of Clinically Significant Differences in Sodium Measurements Due to Abnormal Protein Concentrations Using an Indirect Ion-Selective Electrode Method.
Katrangi W; Baumann NA; Nett RC; Karon BS; Block DR
J Appl Lab Med; 2019 Nov; 4(3):427-432. PubMed ID: 31659081
[TBL] [Abstract][Full Text] [Related]
4. Prevalence of pseudonatremia in a clinical laboratory - role of the water content.
Langelaan ML; Kamp L; Zandijk E; Raijmakers MT
Clin Chem Lab Med; 2017 Mar; 55(4):546-553. PubMed ID: 27676606
[TBL] [Abstract][Full Text] [Related]
5. The challenges of sodium measurements: indirect versus direct ion-selective method.
Refardt J; Sailer CO; Chifu I; Winzeler B; Schnyder I; Fassnacht M; Fenske W; Christ-Crain M
Eur J Endocrinol; 2019 Aug; 181(2):193-199. PubMed ID: 31167167
[TBL] [Abstract][Full Text] [Related]
6. The effect of albumin concentration on plasma sodium and chloride measurements in critically ill patients.
Story DA; Morimatsu H; Egi M; Bellomo R
Anesth Analg; 2007 Apr; 104(4):893-7. PubMed ID: 17377102
[TBL] [Abstract][Full Text] [Related]
7. Effects of total plasma protein concentration on plasma sodium, potassium and chloride measurements by an indirect ion selective electrode measuring system.
Dimeski G; Barnett RJ
Crit Care Resusc; 2005 Mar; 7(1):12-5. PubMed ID: 16548813
[TBL] [Abstract][Full Text] [Related]
8. Effect of low serum total protein on sodium and potassium measurement by ion-selective electrodes in critically ill patients.
Chow E; Fox N; Gama R
Br J Biomed Sci; 2008; 65(3):128-31. PubMed ID: 18986099
[TBL] [Abstract][Full Text] [Related]
9. Effect of Hypoproteinemia on Electrolyte Measurement by Direct and Indirect Ion Selective Electrode Methods.
Gohel M; Makadia JS; Chakrabarti C
J Lab Physicians; 2021 Jun; 13(2):144-147. PubMed ID: 34483560
[No Abstract] [Full Text] [Related]
10. Sodium measurement: effects of differing sampling and analytical methods.
Loughrey CM; Hanna EV; McDonnell M; Archbold GP
Ann Clin Biochem; 2006 Nov; 43(Pt 6):488-93. PubMed ID: 17132280
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the analytical performance of a portable ion-selective electrode meter for measuring whole-blood, plasma, milk, abomasal-fluid, and urine sodium concentrations in cattle.
Megahed AA; Hiew M; Grünberg W; Trefz FM; Constable PD
J Dairy Sci; 2019 Aug; 102(8):7435-7444. PubMed ID: 31202658
[TBL] [Abstract][Full Text] [Related]
12. Glucose interference in direct ion-sensitive electrode sodium measurements.
Al-Musheifri A; Jones GR
Ann Clin Biochem; 2008 Sep; 45(Pt 5):530-2. PubMed ID: 18753432
[TBL] [Abstract][Full Text] [Related]
13. How to Solve the Underestimated Problem of Overestimated Sodium Results in the Hypoproteinemic Patient.
Stove V; Slabbinck A; Vanoverschelde L; Hoste E; De Paepe P; Delanghe J
Crit Care Med; 2016 Feb; 44(2):e83-8. PubMed ID: 26465222
[TBL] [Abstract][Full Text] [Related]
14. Recommendations for measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood. International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). IFCC Scientific Division Working Group on Selective Electrodes.
Burnett RW; Covington AK; Fogh-Andersen N; Külpmann WR; Lewenstam A; Maas AH; Müller-Plathe O; Sachs C; Siggaard-Andersen O; VanKessel AL; Zijlstra WG
Clin Chem Lab Med; 2000 Oct; 38(10):1065-71. PubMed ID: 11140625
[TBL] [Abstract][Full Text] [Related]
15. Frozen human serum reference material for standardization of sodium and potassium measurements in serum or plasma by ion-selective electrode analyzers.
Gunaratna PC; Koch WF; Paule RC; Cormier AD; D'Orazio P; Greenberg N; O'Connell KM; Malenfant A; Okorodudu AO; Miller R
Clin Chem; 1992 Aug; 38(8 Pt 1):1459-65. PubMed ID: 1643715
[TBL] [Abstract][Full Text] [Related]
16. Interference in Ion-Selective Electrodes Due to Proteins and Lipids.
Datta SK; Chopra P
J Appl Lab Med; 2022 Mar; 7(2):589-595. PubMed ID: 34751739
[TBL] [Abstract][Full Text] [Related]
17. Electrolytes in sick neonates - which sodium is the right answer?
King RI; Mackay RJ; Florkowski CM; Lynn AM
Arch Dis Child Fetal Neonatal Ed; 2013 Jan; 98(1):F74-6. PubMed ID: 22215801
[TBL] [Abstract][Full Text] [Related]
18. Comparison of sodium ion levels between an arterial blood gas analyzer and an autoanalyzer in preterm infants admitted to the neonatal intensive care unit: a retrospective study.
Kim H; Kim JK; Cho SC
BMC Pediatr; 2016 Jul; 16():101. PubMed ID: 27439351
[TBL] [Abstract][Full Text] [Related]
19. Discrepancies between sodium concentrations measured by the Kodak Ektachem 700 and by dilutional and direct ion-selective electrode analyzers.
Stone JA; Moriguchi JR; Notto DR; Murphy PE; Dass CJ; Wessels LM; Freier EF
Clin Chem; 1992 Dec; 38(12):2419-22. PubMed ID: 1458577
[TBL] [Abstract][Full Text] [Related]
20. Effect of low protein concentration on serum sodium measurement: pseudohypernatraemia and pseudonormonatraemia!
Lang T; Prinsloo P; Broughton AF; Lawson N; Marenah CB
Ann Clin Biochem; 2002 Jan; 39(Pt 1):66-7. PubMed ID: 11853193
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]