These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 2768409)

  • 1. Determination of diltiazem in human whole blood and plasma by high-performance liquid chromatography using a polymeric reversed-phase column and utilizing a salting-out extraction procedure.
    Rustum AM
    J Chromatogr; 1989 May; 490(2):365-75. PubMed ID: 2768409
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of diltiazem hydrochloride in human serum by high-performance liquid chromatography.
    Chaudhary RS; Gangwal SS; Avachat MK; Shah YN; Jindal KC
    J Chromatogr; 1993 May; 614(2):261-6. PubMed ID: 8314938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of cadralazine in human whole blood using reversed-phase high-performance liquid chromatography: utilizing a salting-out extraction procedure.
    Rustum AM
    J Chromatogr; 1989 Apr; 489(2):345-52. PubMed ID: 2753958
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of cyclophosphamide in whole blood and plasma by reversed-phase high-performance liquid chromatography.
    Rustum AM; Hoffman NE
    J Chromatogr; 1987 Nov; 422():125-34. PubMed ID: 3437001
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-performance liquid chromatographic determination of diltiazem in human plasma after solid-phase and liquid-liquid extraction.
    Zendelovska D; Stafilov T; Stefova M
    Anal Bioanal Chem; 2003 Jul; 376(6):848-53. PubMed ID: 12811463
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simple and rapid reversed-phase high-performance liquid chromatographic determination of baclofen in human plasma with ultraviolet detection. Application to a pharmacokinetic study.
    Rustum AM
    J Chromatogr; 1989 Jan; 487(1):107-15. PubMed ID: 2715253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Estimation of cyclosporin-A in whole blood by simple and rapid reversed-phase HPLC utilizing a salting-out extraction procedure.
    Rustum AM
    J Chromatogr Sci; 1990 Nov; 28(11):594-8. PubMed ID: 2262531
    [TBL] [Abstract][Full Text] [Related]  

  • 8. HPLC determination of diltiazem in human plasma and its application to pharmacokinetics in humans.
    Li K; Zhang X; Zhao F
    Biomed Chromatogr; 2003 Dec; 17(8):522-5. PubMed ID: 14648609
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-performance liquid chromatographic assay for diltiazem in small-volume blood specimens and application to pharmacokinetic studies in rats.
    Scully P; Meehan E; Kelly JG
    J Chromatogr A; 1996 Apr; 729(1-2):297-300. PubMed ID: 9004953
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-performance liquid chromatographic determination of diltiazem and two of its metabolites in plasma using a short alkyl chain silanol deactivated column.
    Rutledge DR; Abadi AH; Lopez LM; Beaudreau CA
    J Chromatogr; 1993 May; 615(1):111-6. PubMed ID: 8340449
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-performance liquid chromatographic determination of diltiazem and four of its metabolites in plasma: evaluation of their stability.
    Dubé LM; Mousseau N; McGilveray IJ
    J Chromatogr; 1988 Aug; 430(1):103-11. PubMed ID: 3215945
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Liquid chromatographic determination of cimetidine in whole blood and plasma by using short polymeric reverse phase column.
    Rustum AM; Hoffman NE
    J Assoc Off Anal Chem; 1988; 71(3):519-22. PubMed ID: 3391953
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of acetaminophen in human plasma by ion-pair reversed-phase high-performance liquid chromatography. Application to a single-dose pharmacokinetic study.
    Rustum AM
    J Chromatogr Sci; 1989 Jan; 27(1):18-22. PubMed ID: 2925824
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-performance liquid chromatographic determination of diltiazem and four of its metabolites in plasma. Application to pharmacokinetics.
    Goebel KJ; Kölle EU
    J Chromatogr; 1985 Dec; 345(2):355-63. PubMed ID: 4086603
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Liquid chromatographic determination of diltiazem and its metabolites using trans isomers as internal standards, with dynamic modification of the solid phase by addition of an amine to the mobile phase.
    Höglund P; Nilsson LG
    J Chromatogr; 1987 Feb; 414(1):109-20. PubMed ID: 3571375
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A simple and sensitive high-performance liquid chromatography assay of diltiazem and main metabolites in renal transplanted patients.
    Christensen H; Carlson E; Asberg A; Schram L; Berg KJ
    Clin Chim Acta; 1999 May; 283(1-2):63-75. PubMed ID: 10404732
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Direct enantiomeric separation of cis-(+/-)diltiazem in plasma by high-performance liquid chromatography with ovomucoid column.
    Rosell G; Camacho A; Parra P
    J Chromatogr; 1993 Sep; 619(1):87-92. PubMed ID: 8245167
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automated high-performance liquid chromatographic and column-switching technique for on-line clean-up and analysis of diltiazem in human plasma.
    Ascalone V; Dal Bo' L
    J Chromatogr; 1987 Dec; 423():239-49. PubMed ID: 3443655
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A rapid HPLC method for the determination of losartan in human plasma using a monolithic column.
    Zarghi A; Foroutan SM; Shafaati A; Khoddam A
    Arzneimittelforschung; 2005; 55(10):569-72. PubMed ID: 16294502
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Application of monolithic column in quantification of gliclazide in human plasma by liquid chromatography.
    Foroutan SM; Zarghi A; Shafaati A; Khoddam A
    J Pharm Biomed Anal; 2006 Oct; 42(4):513-6. PubMed ID: 16797910
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.