BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

258 related articles for article (PubMed ID: 27685138)

  • 1. Difference in dose-volumetric data between the analytical anisotropic algorithm, the dose-to-medium, and the dose-to-water reporting modes of the Acuros XB for lung stereotactic body radiation therapy.
    Mampuya WA; Nakamura M; Hirose Y; Kitsuda K; Ishigaki T; Mizowaki T; Hiraoka M
    J Appl Clin Med Phys; 2016 Sep; 17(5):341-347. PubMed ID: 27685138
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric comparison of analytical anisotropic algorithm and the two dose reporting modes of Acuros XB dose calculation algorithm in volumetric modulated arc therapy of carcinoma lung and carcinoma prostate.
    Gopalakrishnan Z; Bhasi S; P R; Menon SV; B S; Thayil AG; Nair RK
    Med Dosim; 2022 Autumn; 47(3):280-287. PubMed ID: 35690544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. From AAA to Acuros XB-clinical implications of selecting either Acuros XB dose-to-water or dose-to-medium.
    Zifodya JM; Challens CH; Hsieh WL
    Australas Phys Eng Sci Med; 2016 Jun; 39(2):431-9. PubMed ID: 27008647
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dependence of volume dose indices on dose calculation algorithms for VMAT-SBRT plans for peripheral lung tumor.
    Matsuoka T; Araki F; Ohno T; Sakata J; Tominaga H
    Med Dosim; 2019 Autumn; 44(3):284-290. PubMed ID: 30455092
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of Acuros XB algorithm based on RTOG 0813 dosimetric criteria for SBRT lung treatment with RapidArc.
    Rana S; Rogers K; Pokharel S; Cheng C
    J Appl Clin Med Phys; 2014 Jan; 15(1):4474. PubMed ID: 24423844
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical impact of anisotropic analytical algorithm and Acuros XB dose calculation algorithms for intensity modulated radiation therapy in lung cancer patients.
    Abdullah C; Farag H; El-Sheshtawy W; Aboelenein H; Guirguis OW
    J Xray Sci Technol; 2021; 29(6):1019-1031. PubMed ID: 34542053
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms.
    Ong CCH; Ang KW; Soh RCX; Tin KM; Yap JHH; Lee JCL; Bragg CM
    Med Dosim; 2017 Autumn; 42(3):216-222. PubMed ID: 28711478
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans.
    Liang X; Penagaricano J; Zheng D; Morrill S; Zhang X; Corry P; Griffin RJ; Han EY; Hardee M; Ratanatharathom V
    Radiat Oncol; 2016 Jan; 11():10. PubMed ID: 26800883
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric comparison of Acuros XB with collapsed cone convolution/superposition and anisotropic analytic algorithm for stereotactic ablative radiotherapy of thoracic spinal metastases.
    Zhen H; Hrycushko B; Lee H; Timmerman R; Pompoš A; Stojadinovic S; Foster R; Jiang SB; Solberg T; Gu X
    J Appl Clin Med Phys; 2015 Jul; 16(4):181–192. PubMed ID: 26219014
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of a second-dose calculation algorithm to check dosimetric parameters for the dose distribution of a first-dose calculation algorithm for lung SBRT plans.
    Tsuruta Y; Nakamura M; Miyabe Y; Nakata M; Ishihara Y; Mukumoto N; Akimoto M; Ono T; Yano S; Higashimura K; Matsuo Y; Mizowaki T; Hiraoka M
    Phys Med; 2017 Dec; 44():86-95. PubMed ID: 28760507
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods.
    Mitsuyoshi T; Nakamura M; Matsuo Y; Ueki N; Nakamura A; Iizuka Y; Mampuya WA; Mizowaki T; Hiraoka M
    Med Dosim; 2016 Winter; 41(4):305-309. PubMed ID: 27623737
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.
    Tsuruta Y; Nakata M; Nakamura M; Matsuo Y; Higashimura K; Monzen H; Mizowaki T; Hiraoka M
    Med Phys; 2014 Aug; 41(8):081715. PubMed ID: 25086525
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer.
    Han T; Followill D; Mikell J; Repchak R; Molineu A; Howell R; Salehpour M; Mourtada F
    Med Phys; 2013 May; 40(5):051710. PubMed ID: 23635258
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dosimetric Influence of Acuros XB Dose-to-Medium and Dose-to-Water Reporting Modes on Carcinoma Cervix Using Intensity-Modulated Radiation Therapy and Volumetric RapidArc Technique.
    Kumar L; Bhushan M; Kishore V; Chowdhary RL; Barik S; Sharma A; Gairola M
    J Med Phys; 2022; 47(1):10-19. PubMed ID: 35548039
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size.
    Huang B; Wu L; Lin P; Chen C
    Radiat Oncol; 2015 Feb; 10():53. PubMed ID: 25886628
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric impact of switching from AAA to Acuros dose-to-water and dose-to-medium for RapidArc plans of nasopharyngeal carcinomas.
    Sayah R; Felefly T; Zouein L; El Barouky J; Khater N; Farah N; Roukoz C; El Khoury C; Azoury F; Nehme Nasr D; Nasr E
    Cancer Radiother; 2020 Dec; 24(8):842-850. PubMed ID: 33153875
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stereotactic ablative radiation therapy for subcentimeter lung tumors: clinical, dosimetric, and image guidance considerations.
    Louie AV; Senan S; Dahele M; Slotman BJ; Verbakel WF
    Int J Radiat Oncol Biol Phys; 2014 Nov; 90(4):843-9. PubMed ID: 25585783
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma.
    Kan MW; Leung LH; So RW; Yu PK
    Med Phys; 2013 Mar; 40(3):031714. PubMed ID: 23464309
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of the dose quantity used in MV photon optimization on dose distribution, robustness, and complexity.
    Jurado-Bruggeman D; Muñoz-Montplet C; Hernandez V; Saez J; Fuentes-Raspall R
    Med Phys; 2022 Jan; 49(1):648-665. PubMed ID: 34855988
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Benchmarking techniques for stereotactic body radiotherapy for early-stage glottic laryngeal cancer: LINAC-based non-coplanar VMAT vs. Cyberknife planning.
    Zhang Y; Chiu T; Dubas J; Tian Z; Lee P; Gu X; Yan Y; Sher D; Timmerman R; Zhao B
    Radiat Oncol; 2019 Nov; 14(1):193. PubMed ID: 31684993
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.