These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
58 related articles for article (PubMed ID: 27686113)
1. Practical considerations for the application of ear simulators in the calibration of audiometers in the extended high frequency region. Barham R Int J Audiol; 2016 Dec; 55(12):796-801. PubMed ID: 27686113 [TBL] [Abstract][Full Text] [Related]
2. Audiometer calibration: interpreting and applying the standards. Lightfoot GR Br J Audiol; 2000 Oct; 34(5):311-6. PubMed ID: 11081756 [TBL] [Abstract][Full Text] [Related]
3. Audiometric earphone calibration using the IEC 303 reference coupler: a cautionary note. Sherwood TR; Shipton MS Br J Audiol; 1987 Feb; 21(1):75-7. PubMed ID: 3828589 [TBL] [Abstract][Full Text] [Related]
4. High frequency Bekesy audiometry. I: equipment and calibration. Gauz MT; Brey RH; Ahroon WA J Aud Res; 1980 Oct; 20(4):279-94. PubMed ID: 7349307 [TBL] [Abstract][Full Text] [Related]
5. Amplitude variation in calibrated audiometer systems in clinical simulations. Barlow C; Davison L; Ashmore M; Weinstein R Noise Health; 2014; 16(72):299-305. PubMed ID: 25209040 [TBL] [Abstract][Full Text] [Related]
6. The calibration of a prototype occluded ear simulator designed for neonatal hearing assessment applications. Barham R; Olsen ES; Rodrigues D; Barrera-Figueroa S; Sadikoğlu E; Karaböce B J Acoust Soc Am; 2016 Aug; 140(2):806. PubMed ID: 27586713 [TBL] [Abstract][Full Text] [Related]
7. New Measurement Service for Determining Pressure Sensitivity of Type LS2aP Microphones by the Reciprocity Method. Wagner RP; Nedzelnitsky V; Fick SE J Res Natl Inst Stand Technol; 2011; 116(5):761-9. PubMed ID: 26989598 [TBL] [Abstract][Full Text] [Related]
8. Unwanted sounds generated with test tone presentation can spoil extended high-frequency audiometry. Kurakata K; Mizunami T; Matsushita K; Shiraishi K J Acoust Soc Am; 2010 Oct; 128(4):EL157-62. PubMed ID: 20968319 [TBL] [Abstract][Full Text] [Related]
9. Earphone sound pressure output as measured in a standard coupler: effects of microphone protection grid and coupler adapter ring. Beattie RC; Smiarowski RA Ear Hear; 1986 Dec; 7(6):405-9. PubMed ID: 3792684 [TBL] [Abstract][Full Text] [Related]
11. The effect of frequency tolerance on audiometer accuracy. Guelke RW; Floyd JD; van Zyl FJ S Afr Med J; 1977 Dec; 52(24):973-7. PubMed ID: 609969 [TBL] [Abstract][Full Text] [Related]
12. Free-field sensitivity level of audiometric earphones to be used for speech audiometer calibration. Brinkmann K; Richter U Scand Audiol; 1989; 18(2):75-81. PubMed ID: 2756336 [TBL] [Abstract][Full Text] [Related]
13. Calibration matters: I. Sound level meter basics. Chung K J Commun Disord; 2023; 101():106300. PubMed ID: 36638627 [TBL] [Abstract][Full Text] [Related]
14. Smartphone hearing screening with integrated quality control and data management. Swanepoel de W; Myburgh HC; Howe DM; Mahomed F; Eikelboom RH Int J Audiol; 2014 Dec; 53(12):841-9. PubMed ID: 24998412 [TBL] [Abstract][Full Text] [Related]
15. MEMS capacitive accelerometer-based middle ear microphone. Young DJ; Zurcher MA; Semaan M; Megerian CA; Ko WH IEEE Trans Biomed Eng; 2012 Dec; 59(12):3283-92. PubMed ID: 22542650 [TBL] [Abstract][Full Text] [Related]
16. High-frequency pure-tone audiometry in children: a test-retest reliability study relative to ototoxic criteria. Beahan N; Kei J; Driscoll C; Charles B; Khan A Ear Hear; 2012; 33(1):104-11. PubMed ID: 21760512 [TBL] [Abstract][Full Text] [Related]
17. Effect of Power Line Interference on Microphone Calibration Measurements Made at or Near Harmonics of the Power Line Frequency. Wagner RP; Nedzelnitsky V J Res Natl Inst Stand Technol; 2007; 112(2):107-14. PubMed ID: 27110458 [TBL] [Abstract][Full Text] [Related]
18. Long-Term Stability of One-Inch Condenser Microphones Calibrated at the National Institute of Standards and Technology. Wagner RP; Guthrie WF J Res Natl Inst Stand Technol; 2015; 120():164-72. PubMed ID: 26958445 [TBL] [Abstract][Full Text] [Related]
19. Hearing function in a hyperbaric environment. Mendel LL; Knafelc ME; Cudahy EA Undersea Hyperb Med; 2000; 27(2):91-105. PubMed ID: 11011799 [TBL] [Abstract][Full Text] [Related]
20. The simplified HF E-800 audiometer: calibration and normative aspects. Gauz MT; Smith MM J Aud Res; 1985 Apr; 25(2):101-22. PubMed ID: 3842135 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]