These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 27690674)

  • 1. Loop recorders for syncope evaluation: what is the evidence?
    Cheung CC; Krahn AD
    Expert Rev Med Devices; 2016 Nov; 13(11):1021-1027. PubMed ID: 27690674
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experience with implantable loop recorders for recurrent unexplained syncope.
    Brignole M
    Congest Heart Fail; 2008; 14(5 Suppl 2):7-13. PubMed ID: 19891290
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Incidence, diagnostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease.
    Solano A; Menozzi C; Maggi R; Donateo P; Bottoni N; Lolli G; Tomasi C; Croci F; Oddone D; Puggioni E; Brignole M
    Eur Heart J; 2004 Jul; 25(13):1116-9. PubMed ID: 15231369
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Implantable loop recorders in the real world: a study of two Canadian centers.
    Ibrahim OA; Drew D; Hayes CJ; McIntyre W; Seifer CM; Hopman W; Glover B; Baranchuk AM
    J Interv Card Electrophysiol; 2017 Nov; 50(2):179-185. PubMed ID: 29098486
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of event recorders and loop recorders in clinical practice: results of the European Heart Rhythm Association Survey.
    Sciaraffia E; Chen J; Hocini M; Larsen TB; Potpara T; Blomström-Lundqvist C
    Europace; 2014 Sep; 16(9):1384-6. PubMed ID: 25172620
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Safety and outcome of nurse-led syncope clinics and implantable loop recorder implants.
    Eftekhari H; He H; Lee JD; Paul G; Zhupaj A; Lachlan T; Kuehl M; Dhanjal T; Panikker S; Yusuf S; Hayat S; Osman F
    Heart Rhythm; 2022 Mar; 19(3):443-447. PubMed ID: 34767989
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in patients with unexplained syncope].
    Liu ZM; Liu ZP; Guo T
    Zhonghua Xin Xue Guan Bing Za Zhi; 2006 Nov; 34(11):1009-12. PubMed ID: 17288766
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Early use of an implantable loop recorder in syncope evaluation: a randomized study in the context of the French healthcare system (FRESH study).
    Podoleanu C; DaCosta A; Defaye P; Taieb J; Galley D; Bru P; Maury P; Mabo P; Boveda S; Cellarier G; Anselme F; Kouakam C; Delarche N; Deharo JC;
    Arch Cardiovasc Dis; 2014 Oct; 107(10):546-52. PubMed ID: 25241220
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Implantable rhythm devices in the management of vasovagal syncope.
    Solbiati M; Sheldon RS
    Auton Neurosci; 2014 Sep; 184():33-9. PubMed ID: 24916847
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The diagnostic yield of implantable loop recorders in unexplained syncope: A systematic review and meta-analysis.
    Solbiati M; Casazza G; Dipaola F; Barbic F; Caldato M; Montano N; Furlan R; Sheldon RS; Costantino G
    Int J Cardiol; 2017 Mar; 231():170-176. PubMed ID: 28052814
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Diagnostic and therapeutic value of implantable loop recorder: A tertiary care center experience.
    Padmanabhan D; Kancharla K; El-Harasis MA; Isath A; Makkar N; Noseworthy PA; Friedman PA; Cha YM; Kapa S
    Pacing Clin Electrophysiol; 2019 Jan; 42(1):38-45. PubMed ID: 30357866
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Value of Ambulatory Electrocardiographic Monitoring in Syncope.
    Giada F; Bartoletti A
    Cardiol Clin; 2015 Aug; 33(3):361-6. PubMed ID: 26115822
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Implantable loop recorders in evaluation of syncope].
    Christiansen CS; Gjesdal K
    Tidsskr Nor Laegeforen; 2007 Jun; 127(12):1657-9. PubMed ID: 17571107
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Insertable loop recorder use for detection of intermittent arrhythmias.
    Krahn AD; Klein GJ; Skanes AC; Yee R
    Pacing Clin Electrophysiol; 2004 May; 27(5):657-64. PubMed ID: 15125724
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The implantable loop recorder-an important addition to the armentarium in the management of unexplained syncope.
    Shanmugam N; Liew R
    Ann Acad Med Singap; 2012 Mar; 41(3):115-24. PubMed ID: 22538738
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Management of older patients with unexplained, recurrent, traumatic syncope and bifascicular block: Implantable loop recorder versus empiric pacemaker implantation-Results of a propensity-matched analysis.
    Palmisano P; Guerra F; Aspromonte V; Dell'Era G; Pellegrino PL; Laffi M; Uran C; De Bonis S; Accogli M; Dello Russo A; Patti G; Santoro F; Torriglia A; Nigro G; Bisignani A; Coluccia G; Stronati G; Russo V; Ammendola E
    Heart Rhythm; 2022 Oct; 19(10):1696-1703. PubMed ID: 35643299
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Discrepancy between clinical practice and standardized indications for an implantable loop recorder in patients with unexplained syncope.
    Vitale E; Ungar A; Maggi R; Francese M; Lunati M; Colaceci R; Del Rosso A; Castro A; Santini M; Giuli S; Belgini L; Casagranda I; Brignole M
    Europace; 2010 Oct; 12(10):1475-9. PubMed ID: 20876604
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of implantable loop recorders in the diagnosis and management of syncope.
    Farwell DJ; Freemantle N; Sulke AN
    Eur Heart J; 2004 Jul; 25(14):1257-63. PubMed ID: 15246645
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations.
    Locati ET; Vecchi AM; Vargiu S; Cattafi G; Lunati M
    Europace; 2014 Jun; 16(6):914-22. PubMed ID: 24158255
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical impact of the implantable loop recorder in patients with isolated syncope, bundle branch block and negative workup: a randomized multicentre prospective study.
    Da Costa A; Defaye P; Romeyer-Bouchard C; Roche F; Dauphinot V; Deharo JC; Jacon P; Lamaison D; Bathélemy JC; Isaaz K; Laurent G
    Arch Cardiovasc Dis; 2013 Mar; 106(3):146-54. PubMed ID: 23582676
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.