These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

244 related articles for article (PubMed ID: 27693778)

  • 41. Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.
    McCracken MS; Louis DR; Litaker MS; Minyé HM; Oates T; Gordan VV; Marshall DG; Meyerowitz C; Gilbert GH;
    J Prosthodont; 2018 Oct; 27(8):722-732. PubMed ID: 28076661
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Effects of substrate, ceramic thickness, translucency, and cement shade on the color of CAD/CAM lithium-disilicate crowns.
    Czigola A; Abram E; Kovacs ZI; Marton K; Hermann P; Borbely J
    J Esthet Restor Dent; 2019 Sep; 31(5):457-464. PubMed ID: 30957412
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Zirconium dioxide based dental restorations. Studies on clinical performance and fracture behaviour.
    Larsson C
    Swed Dent J Suppl; 2011; (213):9-84. PubMed ID: 21919311
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Tooth substance removal for ceramic single crown materials-an in vitro comparison.
    Schwindling FS; Waldecker M; Rammelsberg P; Rues S; Bömicke W
    Clin Oral Investig; 2019 Aug; 23(8):3359-3366. PubMed ID: 30515576
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Evaluating ceramic crown margins with digital radiography.
    Wahle WM; Masri R; Driscoll C; Romberg E
    J Prosthet Dent; 2018 May; 119(5):777-782. PubMed ID: 28969920
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Ten-year survival of pressed, acid-etched e.max lithium disilicate monolithic and bilayered complete-coverage restorations: Performance and outcomes as a function of tooth position and age.
    Malament KA; Natto ZS; Thompson V; Rekow D; Eckert S; Weber HP
    J Prosthet Dent; 2019 May; 121(5):782-790. PubMed ID: 30955942
    [TBL] [Abstract][Full Text] [Related]  

  • 47. CLINICAL PROTOCOLS: PREPARATION, IMPRESSION AND BONDING OF ALL-CERAMIC GLASS-BASED DISILICATE LITHIUM CROWNS: REVIEW AND CASE REPORT.
    Vadachkoria D; Vadachkoria O
    Georgian Med News; 2017 Apr; (265):94-98. PubMed ID: 28574390
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Cement Type (Adhesive vs. Conventional) May Not Affect Clinical Performance of Zirconia and Lithium Disilicate Tooth-Supported Crowns.
    Oh WS
    J Evid Based Dent Pract; 2020 Jun; 20(2):101415. PubMed ID: 32473801
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Comparison of the Accuracy of Fit of Metal, Zirconia, and Lithium Disilicate Crowns Made from Different Manufacturing Techniques.
    Al Hamad KQ; Al Quran FA; AlJalam SA; Baba NZ
    J Prosthodont; 2019 Jun; 28(5):497-503. PubMed ID: 30719780
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Fracture Strength After Fatigue Loading of Lithium Disilicate Pressed Zirconia Crowns.
    Kim SY; Choi JW; Ju SW; Ahn JS; Yoon MJ; Huh JB
    Int J Prosthodont; 2016; 29(4):369-71. PubMed ID: 27479345
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The complete digital workflow in fixed prosthodontics: a systematic review.
    Joda T; Zarone F; Ferrari M
    BMC Oral Health; 2017 Sep; 17(1):124. PubMed ID: 28927393
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Fracture Resistance of Titanium-Based Lithium Disilicate and Zirconia Implant Restorations.
    Roberts EE; Bailey CW; Ashcraft-Olmscheid DL; Vandewalle KS
    J Prosthodont; 2018 Aug; 27(7):644-650. PubMed ID: 29417647
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Effect of various veneering techniques on mechanical strength of computer-controlled zirconia framework designs.
    Kanat B; Cömlekoğlu EM; Dündar-Çömlekoğlu M; Hakan Sen B; Ozcan M; Ali Güngör M
    J Prosthodont; 2014 Aug; 23(6):445-55. PubMed ID: 24417370
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Convergence Angle of Preparations for Lithium Disilicate Glass-Ceramic Crowns by Dental Students and Its Effect on Crown Retention.
    Aziz A; El-Mowafy O
    J Dent Educ; 2020 Mar; 84(3):329-335. PubMed ID: 32176349
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Assessment of convergence angle of full-coverage porcelain fused to metal crowns in clinical practice.
    Ghafoor R; Siddiqui AA; Rahman M
    Indian J Dent Res; 2012; 23(2):241-6. PubMed ID: 22945717
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Zirconia-Reinforced Lithium Silicate Ceramic - A 2-Year Follow-up of a Clinical Experience with Anterior Crowns.
    Saavedra GSFA; Rodrigues FP; Bottino MA
    Eur J Prosthodont Restor Dent; 2017 Mar; 25(1):57-63. PubMed ID: 28569452
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Substrate masking ability of bilayer and monolithic ceramics used for complete crowns and the effect of association with an opaque resin-based luting agent.
    Bacchi A; Boccardi S; Alessandretti R; Pereira GKR
    J Prosthodont Res; 2019 Jul; 63(3):321-326. PubMed ID: 30755361
    [TBL] [Abstract][Full Text] [Related]  

  • 58. All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems.
    Vult von Steyern P
    Swed Dent J Suppl; 2005; (173):1-69. PubMed ID: 16001730
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Clinical Outcome of Three Different Types of Posterior All-Ceramic Crowns. A 3-Year Follow-up of a Multicenter, Randomized, Controlled Clinical Trial.
    Le M; Dirawi W; Papia E; Larsson C
    Int J Prosthodont; 2023 Nov; 36(5):546-553. PubMed ID: 36484665
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging.
    Atsü SS; Aksan ME; Bulut AC
    Int J Oral Maxillofac Implants; 2019; 34(3):622–630. PubMed ID: 30716141
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.