These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
392 related articles for article (PubMed ID: 27697716)
21. Additively manufactured Ti-29Nb-21Zr shows improved oxide polarization resistance versus Ti-6Al-4V in inflammatory simulating solution. Kurtz MA; Wessinger AC; Mace A; Moreno-Reyes A; Gilbert JL J Biomed Mater Res A; 2023 Oct; 111(10):1538-1553. PubMed ID: 37129046 [TBL] [Abstract][Full Text] [Related]
22. The Influence of Microstructure on the Passive Layer Chemistry and Corrosion Resistance for Some Titanium-Based Alloys. El-Bagoury N; Ahmed SI; Ahmed Abu Ali O; El-Hadad S; Fallatah AM; Mersal GAM; Ibrahim MM; Wysocka J; Ryl J; Boukherroub R; A Amin M Materials (Basel); 2019 Apr; 12(8):. PubMed ID: 30991704 [TBL] [Abstract][Full Text] [Related]
23. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation. Berbel LO; Banczek EDP; Karoussis IK; Kotsakis GA; Costa I PLoS One; 2019; 14(1):e0210530. PubMed ID: 30703125 [TBL] [Abstract][Full Text] [Related]
24. Evaluation of Corrosion Behavior by Measuring Passivation Current Density of Dental Implant Coated with Bioceramic Materials. Hameed HA; Hasan HA; Alam MK Biomed Res Int; 2021; 2021():9934073. PubMed ID: 34222489 [TBL] [Abstract][Full Text] [Related]
25. [Corrosion resistance of a new Ti-12.5Zr-3Nb-2.5Sn alloy]. Hu X; Wei Q; Li CY; Deng JY; Liu S; Zhang LY Zhonghua Kou Qiang Yi Xue Za Zhi; 2010 Sep; 45(9):569-72. PubMed ID: 21122455 [TBL] [Abstract][Full Text] [Related]
26. Corrosion behavior of pure titanium and titanium alloys in various concentrations of Acidulated Phosphate Fluoride (APF) solutions. Matono Y; Nakagawa M; Matsuya S; Ishikawa K; Terada Y Dent Mater J; 2006 Mar; 25(1):104-12. PubMed ID: 16706304 [TBL] [Abstract][Full Text] [Related]
27. Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al-4V alloy after different polishing protocols. Guilherme AS; Henriques GE; Zavanelli RA; Mesquita MF J Prosthet Dent; 2005 Apr; 93(4):378-85. PubMed ID: 15798689 [TBL] [Abstract][Full Text] [Related]
28. Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment. Rosalbino F; Delsante S; Borzone G; Scavino G J Mater Sci Mater Med; 2012 May; 23(5):1129-37. PubMed ID: 22382735 [TBL] [Abstract][Full Text] [Related]
29. [Joint prostheses components of warm-forged and surface treated Ti-6Al-7Nb alloy]. Semlitsch M; Weber H; Streicher RM; Schön R Biomed Tech (Berl); 1991 May; 36(5):112-9. PubMed ID: 1859861 [TBL] [Abstract][Full Text] [Related]
30. Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological media. Leinenbach C; Eifler D Biomaterials; 2006 Mar; 27(8):1200-8. PubMed ID: 16140373 [TBL] [Abstract][Full Text] [Related]
31. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540 [TBL] [Abstract][Full Text] [Related]
32. Toward improved mechanical, tribological, corrosion and in-vitro bioactivity properties of mixed oxide nanotubes on Ti-6Al-7Nb implant using multi-objective PSO. Rafieerad AR; Bushroa AR; Nasiri-Tabrizi B; Kaboli SHA; Khanahmadi S; Amiri A; Vadivelu J; Yusof F; Basirun WJ; Wasa K J Mech Behav Biomed Mater; 2017 May; 69():1-18. PubMed ID: 28027481 [TBL] [Abstract][Full Text] [Related]
33. Electrochemical Analysis of Nano- and Micro-Sized Pore Formed Ti-6Al-4V Alloys in Solution Containing Ca, P, Mn, and Si Ions via Plasma Eletrolytic Oxidation for Bio-Implant Materials. Kang JI; Son MK; Choe HC J Nanosci Nanotechnol; 2021 Jul; 21(7):4022-4028. PubMed ID: 33715737 [TBL] [Abstract][Full Text] [Related]
34. Electrochemical Behaviour of Ti and Ti-6Al-4V Alloy in Phosphate Buffered Saline Solution. Gudić S; Vrsalović L; Kvrgić D; Nagode A Materials (Basel); 2021 Dec; 14(24):. PubMed ID: 34947090 [TBL] [Abstract][Full Text] [Related]
35. Electrochemical corrosion of titanium and titanium-based alloys. Kuphasuk C; Oshida Y; Andres CJ; Hovijitra ST; Barco MT; Brown DT J Prosthet Dent; 2001 Feb; 85(2):195-202. PubMed ID: 11208211 [TBL] [Abstract][Full Text] [Related]
36. Fretting and Fretting Corrosion Behavior of Additively Manufactured Ti-6Al-4V and Ti-Nb-Zr Alloys in Air and Physiological Solutions. Mace AO; Kurtz MA; Gilbert JL J Funct Biomater; 2024 Feb; 15(2):. PubMed ID: 38391891 [TBL] [Abstract][Full Text] [Related]
37. [Effect of fluoride ion on corrosion of two dental titanium alloys]. Cao BW; Chen L Hua Xi Kou Qiang Yi Xue Za Zhi; 2010 Jun; 28(3):261-4. PubMed ID: 20635653 [TBL] [Abstract][Full Text] [Related]
38. Inhibiting Corrosion of Biomedical-Grade Ti-6Al-4V Alloys with Graphene Nanocoating. Malhotra R; Han YM; Morin JLP; Luong-Van EK; Chew RJJ; Castro Neto AH; Nijhuis CA; Rosa V J Dent Res; 2020 Mar; 99(3):285-292. PubMed ID: 31905311 [TBL] [Abstract][Full Text] [Related]