These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
143 related articles for article (PubMed ID: 27702611)
21. Home Self-tonometry Trials Compared with Clinic Tonometry in Patients with Glaucoma. McGlumphy EJ; Mihailovic A; Ramulu PY; Johnson TV Ophthalmol Glaucoma; 2021; 4(6):569-580. PubMed ID: 33845191 [TBL] [Abstract][Full Text] [Related]
22. Comparison of Intraocular Pressure Measurements Obtained by Rebound, Noncontact, and Goldmann Applanation Tonometry in Children. Feng CS; Jin KW; Yi K; Choi DG Am J Ophthalmol; 2015 Nov; 160(5):937-943.e1. PubMed ID: 26210864 [TBL] [Abstract][Full Text] [Related]
23. Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial. Bengtsson B; Leske MC; Hyman L; Heijl A; Ophthalmology; 2007 Feb; 114(2):205-9. PubMed ID: 17097736 [TBL] [Abstract][Full Text] [Related]
24. Pressure phosphene self-tonometry: a comparison with goldmann tonometry in glaucoma patients. Lam DS; Leung DY; Chiu TY; Fan DS; Cheung EY; Wong TY; Lai JS; Tham CC Invest Ophthalmol Vis Sci; 2004 Sep; 45(9):3131-6. PubMed ID: 15326131 [TBL] [Abstract][Full Text] [Related]
25. Self-tonometry as a complement in the investigation of glaucoma patients. Chen E; Quérat L; Åkerstedt C Acta Ophthalmol; 2016 Dec; 94(8):788-792. PubMed ID: 27227556 [TBL] [Abstract][Full Text] [Related]
26. Effect of hemodialysis on intraocular pressure and ocular perfusion pressure. Hu J; Bui KM; Patel KH; Kim H; Arruda JA; Wilensky JT; Vajaranant TS JAMA Ophthalmol; 2013 Dec; 131(12):1525-31. PubMed ID: 24232671 [TBL] [Abstract][Full Text] [Related]
27. Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions. Lee TE; Yoo C; Hwang JY; Lin S; Kim YY Curr Eye Res; 2015 Sep; 40(9):923-9. PubMed ID: 25271991 [TBL] [Abstract][Full Text] [Related]
28. A comparison of long-term intraocular pressure fluctuation in patients treated with bimatoprost or latanoprost. Simmons ST; Bernstein P; Hollander DA Am J Ophthalmol; 2008 Sep; 146(3):473-7. PubMed ID: 18561893 [TBL] [Abstract][Full Text] [Related]
29. The post-natal development of intraocular pressure in normal domestic cats (Felis catus) and in feline congenital glaucoma. Adelman S; Shinsako D; Kiland JA; Yaccarino V; Ellinwood NM; Ben-Shlomo G; McLellan GJ Exp Eye Res; 2018 Jan; 166():70-73. PubMed ID: 29054387 [TBL] [Abstract][Full Text] [Related]
30. Intraocular pressure fluctuation a risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study. Caprioli J; Coleman AL Ophthalmology; 2008 Jul; 115(7):1123-1129.e3. PubMed ID: 18082889 [TBL] [Abstract][Full Text] [Related]
31. [Clinical application of the 24 hour IOP monitoring in the diagnose of the normal tension glaucoma suspects]. Du C; Peng S; Huang W Yan Ke Xue Bao; 2006 Jun; 22(2):68-70, 84. PubMed ID: 17162879 [TBL] [Abstract][Full Text] [Related]
33. Self-tonometry to manage patients with glaucoma and apparently controlled intraocular pressure. Wilensky JT; Gieser DK; Mori MT; Langenberg PW; Zeimer RC Arch Ophthalmol; 1987 Aug; 105(8):1072-5. PubMed ID: 3632415 [TBL] [Abstract][Full Text] [Related]
34. Rebound Self-tonometry Acquisition Time and Ease of Use Evaluated by Newly Trained Optometry Students and Optometrists. Hyatt R; Furtado NM; Eberle D; Jensen K; Tsang T; Kwan J Optom Vis Sci; 2020 Feb; 97(2):94-100. PubMed ID: 32011581 [TBL] [Abstract][Full Text] [Related]
35. Intraocular pressure in children: the effect of body position as assessed by Icare and Tono-Pen tonometers. Dosunmu EO; Marcus I; Tung I; Thiamthat W; Freedman SF Am J Ophthalmol; 2014 Dec; 158(6):1348-1352.e1. PubMed ID: 25217858 [TBL] [Abstract][Full Text] [Related]
36. [Ocular risk factors for progression of primary open angle glaucoma in the Tunisian population]. Loukil I; Korchène N; Hachicha F; Wathek C; Bouguerra C; Mallouch N; Bhiri R; Hijazi A; Zouari B; El Afrit MA J Fr Ophtalmol; 2013 Apr; 36(4):324-30. PubMed ID: 23218598 [TBL] [Abstract][Full Text] [Related]
37. Relation between office intraocular pressure and 24-hour intraocular pressure in patients with primary open-angle glaucoma treated with a combination of topical antiglaucoma eye drops. Nakakura S; Nomura Y; Ataka S; Shiraki K J Glaucoma; 2007 Mar; 16(2):201-4. PubMed ID: 17473730 [TBL] [Abstract][Full Text] [Related]
38. Frequency of asymmetric intraocular pressure fluctuations among patients with and without glaucoma. Realini T; Barber L; Burton D Ophthalmology; 2002 Jul; 109(7):1367-71. PubMed ID: 12093664 [TBL] [Abstract][Full Text] [Related]
39. [Research progress in intraocular pressure monitoring of glaucoma]. Hao J; Zhen Y; Ma JM; Wang NL Zhonghua Yan Ke Za Zhi; 2013 Sep; 49(9):851-6. PubMed ID: 24330937 [TBL] [Abstract][Full Text] [Related]
40. Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma. Sullivan-Mee M; Halverson KD; Qualls C J Glaucoma; 2007 Dec; 16(8):694-9. PubMed ID: 18091457 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]