BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

907 related articles for article (PubMed ID: 27702766)

  • 1. Five-Year Optical Coherence Tomography in Patients With ST-Segment-Elevation Myocardial Infarction Treated With Bare-Metal Versus Everolimus-Eluting Stents.
    Gomez-Lara J; Brugaletta S; Jacobi F; Ortega-Paz L; Ñato M; Roura G; Romaguera R; Ferreiro JL; Teruel L; Gracida M; Martin-Yuste V; Freixa X; Masotti M; Gomez-Hospital JA; Sabate M; Cequier A
    Circ Cardiovasc Interv; 2016 Oct; 9(10):. PubMed ID: 27702766
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The EXAMINATION trial (Everolimus-Eluting Stents Versus Bare-Metal Stents in ST-Segment Elevation Myocardial Infarction): 2-year results from a multicenter randomized controlled trial.
    Sabaté M; Brugaletta S; Cequier A; Iñiguez A; Serra A; Hernádez-Antolín R; Mainar V; Valgimigli M; Tespili M; den Heijer P; Bethencourt A; Vázquez N; Backx B; Serruys PW
    JACC Cardiovasc Interv; 2014 Jan; 7(1):64-71. PubMed ID: 24332423
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Absorb bioresorbable vascular scaffold versus everolimus-eluting metallic stent in ST-segment elevation myocardial infarction: 1-year results of a propensity score matching comparison: the BVS-EXAMINATION Study (bioresorbable vascular scaffold-a clinical evaluation of everolimus eluting coronary stents in the treatment of patients with ST-segment elevation myocardial infarction).
    Brugaletta S; Gori T; Low AF; Tousek P; Pinar E; Gomez-Lara J; Scalone G; Schulz E; Chan MY; Kocka V; Hurtado J; Gomez-Hospital JA; Münzel T; Lee CH; Cequier A; Valdés M; Widimsky P; Serruys PW; Sabaté M
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt B):189-197. PubMed ID: 25616924
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of the vessel healing process after everolimus-eluting stent and bare metal stent implantations in patients with ST-elevation myocardial infarction.
    Yano H; Horinaka S; Watahik M; Watanabe T; Ishimitsu T
    Heart Vessels; 2019 Apr; 34(4):572-582. PubMed ID: 30392104
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Failure Mechanisms and Neoatherosclerosis Patterns in Very Late Drug-Eluting and Bare-Metal Stent Thrombosis.
    Nakamura D; Attizzani GF; Toma C; Sheth T; Wang W; Soud M; Aoun R; Tummala R; Leygerman M; Fares A; Mehanna E; Nishino S; Fung A; Costa MA; Bezerra HG
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27582113
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of Post-Dilatation Following Primary PCI With Everolimus-Eluting Bioresorbable Scaffold Versus Everolimus-Eluting Metallic Stent Implantation: An Angiographic and Optical Coherence Tomography TROFI II Substudy.
    Yamaji K; Brugaletta S; Sabaté M; Iñiguez A; Jensen LO; Cequier A; Hofma SH; Christiansen EH; Suttorp M; van Es GA; Sotomi Y; Onuma Y; Serruys PW; Windecker S; Räber L
    JACC Cardiovasc Interv; 2017 Sep; 10(18):1867-1877. PubMed ID: 28935079
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Strut coverage and vessel wall response to zotarolimus-eluting and bare-metal stents implanted in patients with ST-segment elevation myocardial infarction: the OCTAMI (Optical Coherence Tomography in Acute Myocardial Infarction) Study.
    Guagliumi G; Sirbu V; Bezerra H; Biondi-Zoccai G; Fiocca L; Musumeci G; Matiashvili A; Lortkipanidze N; Tahara S; Valsecchi O; Costa M
    JACC Cardiovasc Interv; 2010 Jun; 3(6):680-7. PubMed ID: 20630463
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Two-year outcomes after first- or second-generation drug-eluting or bare-metal stent implantation in all-comer patients undergoing percutaneous coronary intervention: a pre-specified analysis from the PRODIGY study (PROlonging Dual Antiplatelet Treatment After Grading stent-induced Intimal hyperplasia studY).
    Valgimigli M; Tebaldi M; Borghesi M; Vranckx P; Campo G; Tumscitz C; Cangiano E; Minarelli M; Scalone A; Cavazza C; Marchesini J; Parrinello G;
    JACC Cardiovasc Interv; 2014 Jan; 7(1):20-8. PubMed ID: 24332420
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.
    Poerner TC; Otto S; Gassdorf J; Nitsche K; Janiak F; Scheller B; Goebel B; Jung C; Figulla HR
    Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of vascular response between everolimus-eluting stent and bare metal stent implantation in ST-segment elevation myocardial infarction assessed by optical coherence tomography.
    Ino Y; Kubo T; Tanaka A; Liu Y; Tanimoto T; Kitabata H; Shiono Y; Shimamura K; Orii M; Komukai K; Satogami K; Matsuo Y; Yamano T; Yamaguchi T; Hirata K; Imanishi T; Akasaka T
    Eur Heart J Cardiovasc Imaging; 2015 May; 16(5):513-20. PubMed ID: 25428946
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials.
    Sabaté M; Räber L; Heg D; Brugaletta S; Kelbaek H; Cequier A; Ostojic M; Iñiguez A; Tüller D; Serra A; Baumbach A; von Birgelen C; Hernandez-Antolin R; Roffi M; Mainar V; Valgimigli M; Serruys PW; Jüni P; Windecker S
    JACC Cardiovasc Interv; 2014 Jan; 7(1):55-63. PubMed ID: 24332419
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Five-year clinical outcomes and intracoronary imaging findings of the COMFORTABLE AMI trial: randomized comparison of biodegradable polymer-based biolimus-eluting stents with bare-metal stents in patients with acute ST-segment elevation myocardial infarction.
    Räber L; Yamaji K; Kelbæk H; Engstrøm T; Baumbach A; Roffi M; von Birgelen C; Taniwaki M; Moschovitis A; Zaugg S; Ostojic M; Pedrazzini G; Karagiannis-Voules DA; Lüscher TF; Kornowski R; Tüller D; Vukcevic V; Heg D; Windecker S
    Eur Heart J; 2019 Jun; 40(24):1909-1919. PubMed ID: 30851032
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The efficacy of everolimus-eluting stent implantation in patients with ST-segment elevation myocardial infarction: outcomes of 2-year clinical follow-up.
    Yano H; Horinaka S; Ishikawa M; Ishimitsu T
    Heart Vessels; 2016 Oct; 31(10):1609-15. PubMed ID: 26686370
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does Large Vessel Size Justify Use of Bare-Metal Stents in Primary Percutaneous Coronary Intervention?
    Costa F; Brugaletta S; Pernigotti A; Flores-Ulmanzor E; Ortega-Paz L; Cequier A; Iniguez A; Serra A; Jiménez-Quevedo P; Mainar V; Campo G; Tespili M; den Heijer P; Bethencourt A; Vazquez N; van Es GA; Backx B; Valgimigli M; Serruys P; Sabaté M
    Circ Cardiovasc Interv; 2019 Sep; 12(9):e007705. PubMed ID: 31451013
    [TBL] [Abstract][Full Text] [Related]  

  • 15. First results of the DEB-AMI (drug eluting balloon in acute ST-segment elevation myocardial infarction) trial: a multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in primary percutaneous coronary intervention with 6-month angiographic, intravascular, functional, and clinical outcomes.
    Belkacemi A; Agostoni P; Nathoe HM; Voskuil M; Shao C; Van Belle E; Wildbergh T; Politi L; Doevendans PA; Sangiorgi GM; Stella PR
    J Am Coll Cardiol; 2012 Jun; 59(25):2327-37. PubMed ID: 22503057
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction-TROFI II trial.
    Sabaté M; Windecker S; Iñiguez A; Okkels-Jensen L; Cequier A; Brugaletta S; Hofma SH; Räber L; Christiansen EH; Suttorp M; Pilgrim T; Anne van Es G; Sotomi Y; García-García HM; Onuma Y; Serruys PW
    Eur Heart J; 2016 Jan; 37(3):229-40. PubMed ID: 26405232
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.
    Ohtani H; Kimura S; Sugiyama T; Hishikari K; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hikita H; Ashikaga T; Takahashi A; Isobe M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcomes with various drug-eluting or bare metal stents in patients with ST-segment-elevation myocardial infarction: a mixed treatment comparison analysis of trial level data from 34 068 patient-years of follow-up from randomized trials.
    Bangalore S; Amoroso N; Fusaro M; Kumar S; Feit F
    Circ Cardiovasc Interv; 2013 Aug; 6(4):378-90. PubMed ID: 23922145
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials.
    Alsidawi S; Effat M; Rahman S; Abdallah M; Leesar M
    Cardiovasc Ther; 2015 Dec; 33(6):360-6. PubMed ID: 26363283
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Neoatherosclerosis in Patients With Coronary Stent Thrombosis: Findings From Optical Coherence Tomography Imaging (A Report of the PRESTIGE Consortium).
    Joner M; Koppara T; Byrne RA; Castellanos MI; Lewerich J; Novotny J; Guagliumi G; Xhepa E; Adriaenssens T; Godschalk TC; Malik N; Alfonso F; Tada T; Neumann FJ; Desmet W; Ten Berg JM; Gershlick AH; Feldman LJ; Massberg S; Kastrati A;
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1340-1350. PubMed ID: 30025727
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 46.