171 related articles for article (PubMed ID: 2770636)
21. A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources.
Meigooni AS; Meli JA; Nath R
Med Phys; 1988; 15(5):695-701. PubMed ID: 3185404
[TBL] [Abstract][Full Text] [Related]
22. A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source.
Karaiskos P; Angelopoulos A; Baras P; Sakelliou L; Sandilos P; Dardoufas K; Vlachos L
Med Phys; 1999 Aug; 26(8):1498-502. PubMed ID: 10501049
[TBL] [Abstract][Full Text] [Related]
23. Dose distribution of 125I sources in different tissues.
Huang DY; Schell MC; Weaver KA; Ling CC
Med Phys; 1990; 17(5):826-32. PubMed ID: 2233568
[TBL] [Abstract][Full Text] [Related]
24. The use of directional interstitial sources to improve dosimetry in breast brachytherapy.
Lin L; Patel RR; Thomadsen BR; Henderson DL
Med Phys; 2008 Jan; 35(1):240-7. PubMed ID: 18293579
[TBL] [Abstract][Full Text] [Related]
25. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.
Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P
Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828
[TBL] [Abstract][Full Text] [Related]
26. Multi-species prostate implant treatment plans incorporating 192Ir and 125I using a Greedy Heuristic based 3D optimization algorithm.
Chaswal V; Yoo S; Thomadsen BR; Henderson DL
Med Phys; 2007 Feb; 34(2):436-44. PubMed ID: 17388159
[TBL] [Abstract][Full Text] [Related]
27. A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an 125I seed already having AAPM consensus data.
Aryal P; Molloy JA; Rivard MJ
Med Phys; 2014 Feb; 41(2):021702. PubMed ID: 24506593
[TBL] [Abstract][Full Text] [Related]
28. Treatment planning dosimetric parameters for 192Ir seed at short distances: effects of air channels and neighboring seeds based on Monte Carlo study.
Patel NS; Chiu-Tsao ST; Shih JA; Ho Y; Tsao HS; Harrison LB
Med Phys; 2004 Jun; 31(6):1521-8. PubMed ID: 15259656
[TBL] [Abstract][Full Text] [Related]
29. EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources.
Taylor RE; Rogers DW
Med Phys; 2008 Nov; 35(11):4933-44. PubMed ID: 19070227
[TBL] [Abstract][Full Text] [Related]
30. Thermoluminescent dosimetry of the selectseed 125I interstitial brachytherapy seed.
Anagnostopoulos G; Baltas D; Karaiskos P; Sandilos P; Papagiannis P; Sakelliou L
Med Phys; 2002 May; 29(5):709-16. PubMed ID: 12033566
[TBL] [Abstract][Full Text] [Related]
31. 192Ir or 125I prostate brachytherapy as a boost to external beam radiotherapy in locally advanced prostatic cancer: a dosimetric point of view.
Nickers P; Thissen B; Jansen N; Deneufbourg JM
Radiother Oncol; 2006 Jan; 78(1):47-52. PubMed ID: 16216365
[TBL] [Abstract][Full Text] [Related]
32. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.
Reed JL; Rasmussen BE; Davis SD; Micka JA; Culberson WS; DeWerd LA
Med Phys; 2014 Dec; 41(12):122103. PubMed ID: 25471976
[TBL] [Abstract][Full Text] [Related]
33. Polymer gel dosimetry for the TG-43 dosimetric characterization of a new 125I interstitial brachytherapy seed.
Papagiannis P; Pantelis E; Georgiou E; Karaiskos P; Angelopoulos A; Sakelliou L; Stiliaris S; Baltas D; Seimenis I
Phys Med Biol; 2006 Apr; 51(8):2101-11. PubMed ID: 16585848
[TBL] [Abstract][Full Text] [Related]
34. Effect of improved TLD dosimetry on the determination of dose rate constants for (125)I and (103)Pd brachytherapy seeds.
Rodriguez M; Rogers DW
Med Phys; 2014 Nov; 41(11):114301. PubMed ID: 25370677
[TBL] [Abstract][Full Text] [Related]
35. Influence of the variation of energy spectra with depth in the dosimetry of 192Ir using LiF TLD.
Meigooni AS; Meli JA; Nath R
Phys Med Biol; 1988 Oct; 33(10):1159-70. PubMed ID: 3194446
[TBL] [Abstract][Full Text] [Related]
36. Study of encapsulated 170Tm sources for their potential use in brachytherapy.
Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ
Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484
[TBL] [Abstract][Full Text] [Related]
37. Dosimetric characteristics of the Pharma Seed model BT-125-I source.
Popescu CC; Wise J; Sowards K; Meigooni AS; Ibbott GS
Med Phys; 2000 Sep; 27(9):2174-81. PubMed ID: 11011748
[TBL] [Abstract][Full Text] [Related]
38. Anisotropy function for 192Ir low-dose-rate brachytherapy sources: an EGS4 Monte Carlo study.
Capote R; Mainegra E; López E
Phys Med Biol; 2001 May; 46(5):1487-99. PubMed ID: 11384066
[TBL] [Abstract][Full Text] [Related]
39. Monte Carlo dosimetry of the VariSource high dose rate 192Ir source.
Wang R; Sloboda RS
Med Phys; 1998 Apr; 25(4):415-23. PubMed ID: 9571607
[TBL] [Abstract][Full Text] [Related]
40. Thermoluminescent dosimetry of the Symmetra 125I model I25.S06 interstitial brachytherapy seed.
Patel NS; Chiu-Tsao ST; Williamson JF; Fan P; Duckworth T; Shasha D; Harrison LB
Med Phys; 2001 Aug; 28(8):1761-9. PubMed ID: 11548947
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]