These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
280 related articles for article (PubMed ID: 27707438)
41. Sleep assessment by means of a wrist actigraphy-based algorithm: agreement with polysomnography in an ambulatory study on older adults. Regalia G; Gerboni G; Migliorini M; Lai M; Pham J; Puri N; Pavlova MK; Picard RW; Sarkis RA; Onorati F Chronobiol Int; 2021 Mar; 38(3):400-414. PubMed ID: 33213222 [TBL] [Abstract][Full Text] [Related]
42. Validation of an automated wireless system for sleep monitoring during daytime naps. Cellini N; McDevitt EA; Ricker AA; Rowe KM; Mednick SC Behav Sleep Med; 2015; 13(2):157-68. PubMed ID: 24564261 [TBL] [Abstract][Full Text] [Related]
43. Home monitoring of sleep with a temporary-tattoo EEG, EOG and EMG electrode array: a feasibility study. Shustak S; Inzelberg L; Steinberg S; Rand D; David Pur M; Hillel I; Katzav S; Fahoum F; De Vos M; Mirelman A; Hanein Y J Neural Eng; 2019 Apr; 16(2):026024. PubMed ID: 30566912 [TBL] [Abstract][Full Text] [Related]
44. Software thresholds alter the bias of actigraphy for monitoring sleep in team-sport athletes. Fuller KL; Juliff L; Gore CJ; Peiffer JJ; Halson SL J Sci Med Sport; 2017 Aug; 20(8):756-760. PubMed ID: 28189461 [TBL] [Abstract][Full Text] [Related]
45. Direct comparison of two actigraphy devices with polysomnographically recorded naps in healthy young adults. Cellini N; Buman MP; McDevitt EA; Ricker AA; Mednick SC Chronobiol Int; 2013 Jun; 30(5):691-8. PubMed ID: 23721120 [TBL] [Abstract][Full Text] [Related]
46. Automatic scoring of sleep stages and cortical arousals using two electrodes on the forehead: validation in healthy adults. Popovic D; Khoo M; Westbrook P J Sleep Res; 2014 Apr; 23(2):211-21. PubMed ID: 24313630 [TBL] [Abstract][Full Text] [Related]
47. Heightened Background Cortical Synchrony in Patients With Epilepsy: EEG Phase Synchrony Analysis During Awake and Sleep Stages Using Novel Ensemble Measure. Nayak CS; Mariyappa N; Majumdar KK; Prasad PD; Ravi GS; Nagappa M; Kandavel T; Taly AB; Sinha S Clin EEG Neurosci; 2018 May; 49(3):177-186. PubMed ID: 29161907 [TBL] [Abstract][Full Text] [Related]
48. Accurate whole-night sleep monitoring with dry-contact ear-EEG. Mikkelsen KB; Tabar YR; Kappel SL; Christensen CB; Toft HO; Hemmsen MC; Rank ML; Otto M; Kidmose P Sci Rep; 2019 Nov; 9(1):16824. PubMed ID: 31727953 [TBL] [Abstract][Full Text] [Related]
49. Detecting REM sleep from the finger: an automatic REM sleep algorithm based on peripheral arterial tone (PAT) and actigraphy. Herscovici S; Pe'er A; Papyan S; Lavie P Physiol Meas; 2007 Feb; 28(2):129-40. PubMed ID: 17237585 [TBL] [Abstract][Full Text] [Related]
50. The PAM-RL ambulatory device for detection of periodic leg movements: a validation study. Sforza E; Johannes M; Claudio B Sleep Med; 2005 Sep; 6(5):407-13. PubMed ID: 16139771 [TBL] [Abstract][Full Text] [Related]
51. Polysomnography using abbreviated signal montages: impact on sleep and cortical arousal scoring. Ruehland WR; Churchward TJ; Schachter LM; Lakey T; Tarquinio N; O'Donoghue FJ; Barnes M; Rochford PD Sleep Med; 2015 Jan; 16(1):173-80. PubMed ID: 25547033 [TBL] [Abstract][Full Text] [Related]
52. Validity of an algorithm for determining sleep/wake states using a new actigraph. Nakazaki K; Kitamura S; Motomura Y; Hida A; Kamei Y; Miura N; Mishima K J Physiol Anthropol; 2014 Oct; 33(1):31. PubMed ID: 25282356 [TBL] [Abstract][Full Text] [Related]
53. Wireless communication interface for EEG/PSG Holter monitor. Velarde Reyes E; Marante Rizo F; Santos BM; Jorge JG; Martin Gonzalez F J Med Eng Technol; 2010 Apr; 34(3):172-7. PubMed ID: 20121457 [TBL] [Abstract][Full Text] [Related]
54. Improving Sleep Quality Assessment Using Wearable Sensors by Including Information From Postural/Sleep Position Changes and Body Acceleration: A Comparison of Chest-Worn Sensors, Wrist Actigraphy, and Polysomnography. Razjouyan J; Lee H; Parthasarathy S; Mohler J; Sharafkhaneh A; Najafi B J Clin Sleep Med; 2017 Nov; 13(11):1301-1310. PubMed ID: 28992827 [TBL] [Abstract][Full Text] [Related]
55. Accuracy of Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP Versus Polysomnography: Systematic Review. Schyvens AM; Van Oost NC; Aerts JM; Masci F; Peters B; Neven A; Dirix H; Wets G; Ross V; Verbraecken J JMIR Mhealth Uhealth; 2024 Mar; 12():e52192. PubMed ID: 38557808 [TBL] [Abstract][Full Text] [Related]
56. Data-driven modeling of sleep EEG and EOG reveals characteristics indicative of pre-Parkinson's and Parkinson's disease. Christensen JA; Zoetmulder M; Koch H; Frandsen R; Arvastson L; Christensen SR; Jennum P; Sorensen HB J Neurosci Methods; 2014 Sep; 235():262-76. PubMed ID: 25088694 [TBL] [Abstract][Full Text] [Related]
57. The Dreem Headband compared to polysomnography for electroencephalographic signal acquisition and sleep staging. Arnal PJ; Thorey V; Debellemaniere E; Ballard ME; Bou Hernandez A; Guillot A; Jourde H; Harris M; Guillard M; Van Beers P; Chennaoui M; Sauvet F Sleep; 2020 Nov; 43(11):. PubMed ID: 32433768 [TBL] [Abstract][Full Text] [Related]
58. Quantity and quality of sleep in the surgical intensive care unit: are our patients sleeping? Friese RS; Diaz-Arrastia R; McBride D; Frankel H; Gentilello LM J Trauma; 2007 Dec; 63(6):1210-4. PubMed ID: 18212640 [TBL] [Abstract][Full Text] [Related]
59. Sleep Staging Monitoring Based on Sonar Smartphone Technology. Zaffaroni A; Coffey S; Dodd S; Kilroy H; Lyon G; O'Rourke D; Lederer K; Fietze I; Penzel T Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():2230-2233. PubMed ID: 31946344 [TBL] [Abstract][Full Text] [Related]