These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 27707502)

  • 1. Leucite and cooling rate effect on porcelain-zirconia mechanical behavior.
    Meirelles PD; Spigolon YO; Borba M; Benetti P
    Dent Mater; 2016 Dec; 32(12):e382-e388. PubMed ID: 27707502
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of slow-cooling protocol on biaxial flexural strengths of bilayered porcelain-ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) disks.
    Sawada T; Wagner V; Schille C; Spintzyk S; Schweizer E; Geis-Gerstorfer J
    Dent Mater; 2019 Feb; 35(2):270-282. PubMed ID: 30522698
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improving the compatibility of an Y-TZP/porcelain system using a new composite interlayer composition.
    Passos SP; Linke B; Major PW; Nychka JA
    J Mech Behav Biomed Mater; 2017 Jan; 65():11-19. PubMed ID: 27544615
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics.
    Lin WS; Ercoli C; Feng C; Morton D
    J Prosthodont; 2012 Jul; 21(5):353-62. PubMed ID: 22462639
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of extreme cooling methods on mechanical properties and shear bond strength of bilayered porcelain/3Y-TZP specimens.
    Almeida AA; Longhini D; Domingues NB; Santos C; Adabo GL
    J Dent; 2013 Apr; 41(4):356-62. PubMed ID: 23353069
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pressed ceramics onto zirconia. Part 2: indentation fracture and influence of cooling rate on residual stresses.
    Choi JE; Waddell JN; Swain MV
    Dent Mater; 2011 Nov; 27(11):1111-8. PubMed ID: 21908034
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biaxial flexural strength of the bilayered disk composed of ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) and veneering porcelain.
    Sawada T; Schille C; Wagner V; Spintzyk S; Schweizer E; Geis-Gerstorfer J
    Dent Mater; 2018 Aug; 34(8):1199-1210. PubMed ID: 29793794
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of time period on biaxial strength for different Y-TZP veneering porcelains.
    Fahmi M; Giordano R; Pober R
    J Esthet Restor Dent; 2020 Jul; 32(5):505-511. PubMed ID: 32564471
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of cooling protocol on mechanical properties and microstructure of dental veneering ceramics.
    Tanaka CB; Ahmad NHB; Ellakwa A; Kruzic JJ
    Dent Mater; 2019 Oct; 35(10):1498-1505. PubMed ID: 31400983
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bending strength of zirconia/porcelain functionally graded materials prepared using spark plasma sintering.
    Tsukada G; Sueyoshi H; Kamibayashi H; Tokuda M; Torii M
    J Dent; 2014 Dec; 42(12):1569-76. PubMed ID: 25280989
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of surface treatment of the interfacial surface on fatigue-related microtensile bond strength of milled zirconia to veneering porcelain.
    Harding AB; Norling BK; Teixeira EC
    J Prosthodont; 2012 Jul; 21(5):346-52. PubMed ID: 22443122
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of porcelain thickness and surface liner application on the fracture behavior of a ceramic system.
    Benetti P; Pelogia F; Valandro LF; Bottino MA; Bona AD
    Dent Mater; 2011 Sep; 27(9):948-53. PubMed ID: 21705061
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Extended glaze firings for porcelain-veneered zirconia: Effects on the mechanical and optical behavior.
    Rodrigues CDS; Aurélio IL; Fraga S; Kaizer MDR; Zhang Y; May LG
    Dent Mater; 2021 Jul; 37(7):1096-1106. PubMed ID: 33865620
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Why a zero CTE mismatch may be better for veneered Y-TZP structures.
    Jikihara AN; Tanaka CB; Ballester RY; Swain MV; Versluis A; Meira JBC
    J Mech Behav Biomed Mater; 2019 Aug; 96():261-268. PubMed ID: 31075747
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microstructure and nanoindentation analyses of low-temperature aging on the zirconia-porcelain interface.
    Peng MD; Wei JQ; Wang YN; Li Q
    J Mech Behav Biomed Mater; 2017 Feb; 66():119-126. PubMed ID: 27866055
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a high fracture toughness composite ceramic for dental applications.
    Aboushelib MN; Kleverlaan CJ; Feilzer AJ
    J Prosthodont; 2008 Oct; 17(7):538-44. PubMed ID: 18761572
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns.
    Belli R; Frankenberger R; Appelt A; Schmitt J; Baratieri LN; Greil P; Lohbauer U
    Dent Mater; 2013 Feb; 29(2):181-90. PubMed ID: 23261021
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The use of slow heating and slow cooling regimens to strengthen porcelain fused to zirconia.
    Tan JP; Sederstrom D; Polansky JR; McLaren EA; White SN
    J Prosthet Dent; 2012 Mar; 107(3):163-9. PubMed ID: 22385692
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Antagonist wear of three CAD/CAM anatomic contour zirconia ceramics.
    Park JH; Park S; Lee K; Yun KD; Lim HP
    J Prosthet Dent; 2014 Jan; 111(1):20-9. PubMed ID: 24199603
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Translucent zirconia in the ceramic scenario for monolithic restorations: A flexural strength and translucency comparison test.
    Carrabba M; Keeling AJ; Aziz A; Vichi A; Fabian Fonzar R; Wood D; Ferrari M
    J Dent; 2017 May; 60():70-76. PubMed ID: 28274651
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.