These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
471 related articles for article (PubMed ID: 27717760)
21. Reducing Radiation Dose and Improving Image Quality in CT Portal Venography Using 80 kV and Adaptive Statistical Iterative Reconstruction-V in Slender Patients. Ren Z; Zhang X; Hu Z; Li D; Liu Z; Wei D; Jia Y; Yu N; Yu Y; Lei Y; Chen X; Guo C; Ren Z; He T Acad Radiol; 2020 Feb; 27(2):233-243. PubMed ID: 31031186 [TBL] [Abstract][Full Text] [Related]
22. Combination of Adaptive Statistical Iterative Reconstruction-V and Lower Tube Voltage During Craniocervical Computed Tomographic Angiography Yields Better Image Quality with a Reduced Radiation Dose. Chen CW; Chen PA; Chou CC; Fu JH; Wang PC; Hsu SH; Lai PH Acad Radiol; 2019 Aug; 26(8):e233-e240. PubMed ID: 30195416 [TBL] [Abstract][Full Text] [Related]
23. Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography. Lee JW; Lee G; Lee NK; Moon JI; Ju YH; Suh YJ; Jeong YJ J Comput Assist Tomogr; 2016; 40(5):777-83. PubMed ID: 27454785 [TBL] [Abstract][Full Text] [Related]
24. Potential value of the PixelShine deep learning algorithm for increasing quality of 70 kVp+ASiR-V reconstruction pelvic arterial phase CT images. Tian SF; Liu AL; Liu JH; Liu YJ; Pan JD Jpn J Radiol; 2019 Feb; 37(2):186-190. PubMed ID: 30523499 [TBL] [Abstract][Full Text] [Related]
25. Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake. Pan YY; Zhou SC; Wang YJ; Li Q; Zhu TT; Liu CX; Guan HX Curr Med Sci; 2020 Feb; 40(1):178-183. PubMed ID: 32166681 [TBL] [Abstract][Full Text] [Related]
26. CT pulmonary angiography: simultaneous low-pitch dual-source acquisition mode with 70 kVp and 40 ml of contrast medium and comparison with high-pitch spiral dual-source acquisition with automated tube potential selection. Boos J; Kröpil P; Lanzman RS; Aissa J; Schleich C; Heusch P; Sawicki LM; Antoch G; Thomas C Br J Radiol; 2016 Jun; 89(1062):20151059. PubMed ID: 27007972 [TBL] [Abstract][Full Text] [Related]
27. A BMI-adjusted ultra-low-dose CT angiography protocol for the peripheral arteries-Image quality, diagnostic accuracy and radiation exposure. Schreiner MM; Platzgummer H; Unterhumer S; Weber M; Mistelbauer G; Loewe C; Schernthaner RE Eur J Radiol; 2017 Aug; 93():149-156. PubMed ID: 28668409 [TBL] [Abstract][Full Text] [Related]
28. [Combined use of wide-detector and adaptive statistical iterative reconstruction-V technique in abdominal CT with low radiation dose]. Wang HX; Lü PJ; Yue SW; Chang LY; Li Y; Zhao HP; Li WR; Gao JB Zhonghua Yi Xue Za Zhi; 2017 Dec; 97(45):3567-3572. PubMed ID: 29275597 [No Abstract] [Full Text] [Related]
29. High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses. Li W; Diao K; Wen Y; Shuai T; You Y; Zhao J; Liao K; Lu C; Yu J; He Y; Li Z Eur Radiol; 2022 May; 32(5):2912-2920. PubMed ID: 35059803 [TBL] [Abstract][Full Text] [Related]
30. Standard and reduced radiation dose liver CT images: adaptive statistical iterative reconstruction versus model-based iterative reconstruction-comparison of findings and image quality. Shuman WP; Chan KT; Busey JM; Mitsumori LM; Choi E; Koprowicz KM; Kanal KM Radiology; 2014 Dec; 273(3):793-800. PubMed ID: 25170546 [TBL] [Abstract][Full Text] [Related]
31. Application of High-pitch CT Pulmonary Angiography at 70 kV Tube Voltage with 15 ml Contrast Medium Using Third-generation Dual-source CT. DU Q; Sui X; Song W; Song L; Xu X Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2017 Feb; 39(1):28-33. PubMed ID: 28270280 [TBL] [Abstract][Full Text] [Related]
32. Evaluation of BMI-based tube voltage selection in CT colonography: A prospective comparison of low kV versus routine 120 kV protocol. Li B; Wang X; Fan Y; Wang S; Tong X; Zhang J; Li J; Liu Y J Appl Clin Med Phys; 2023 May; 24(5):e13955. PubMed ID: 36897536 [TBL] [Abstract][Full Text] [Related]
33. [Applied research of CT angiography of lower extremities by using 100 kVp and iodixanol(270 mg I/ml) combined with iDose(4) iterative reconstruction technique]. Chen B; Xu L; Cheng J; He H; Kong Q; Yan Z; Xu X; Xiong S Zhonghua Yi Xue Za Zhi; 2015 Dec; 95(47):3833-8. PubMed ID: 27337800 [TBL] [Abstract][Full Text] [Related]
34. Radiation dose reduction in cardiovascular CT angiography with iterative reconstruction (AIDR 3D) in a swine model: a model of paediatric cardiac imaging. Zhao P; Hou Y; Liu Q; Ma Y; Guo Q Clin Radiol; 2016 Jul; 71(7):716.e7-716.e14. PubMed ID: 27180082 [TBL] [Abstract][Full Text] [Related]
35. [Applied research of "quadri-low" combined with automatic tube current modulation and iterative model reconstruction technology in head and neck CT angiography]. Cai W; Hu CH; Wang XM; Hu S; Bao J; Gong JP; Fan GH; Zhang W; Shi D; Qian MH Zhonghua Yi Xue Za Zhi; 2018 Jan; 98(1):30-35. PubMed ID: 29343026 [No Abstract] [Full Text] [Related]
36. Iterative reconstructed ultra high pitch CT pulmonary angiography with cardiac bowtie-shaped filter in the acute setting: effect on dose and image quality. Co SJ; Mayo J; Liang T; Krzymyk K; Yousefi M; Nicolaou S Eur J Radiol; 2013 Sep; 82(9):1571-6. PubMed ID: 23777744 [TBL] [Abstract][Full Text] [Related]
37. Achieving consistent image quality and overall radiation dose reduction for coronary CT angiography with body mass index-dependent tube voltage and tube current selection. Wang G; Gao J; Zhao S; Sun X; Chen X; Cui X Clin Radiol; 2014 Sep; 69(9):945-51. PubMed ID: 24909505 [TBL] [Abstract][Full Text] [Related]
38. Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol. Chen Y; Liu Z; Li M; Yu Y; Jia Y; Ma G; Hu Z; Wei D; Li D; He T Eur Radiol; 2019 Jun; 29(6):3036-3043. PubMed ID: 30506217 [TBL] [Abstract][Full Text] [Related]
39. Reducing contrast medium dose with low photon energy images in renal dual-energy spectral CT angiography and adaptive statistical iterative reconstruction (ASIR). Zhang X; Chen J; Yu N; Ren Z; Tian Q; Tian X; Jia Y; He T; Guo C Br J Radiol; 2021 Apr; 94(1120):20200974. PubMed ID: 33684310 [TBL] [Abstract][Full Text] [Related]
40. Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography. Zhang T; Geng X; Li D; Xu Y; Zhao Y Dentomaxillofac Radiol; 2021 Jul; 50(5):20200428. PubMed ID: 33353399 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]