These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
43. AVDNet: Joint coronary artery and vein segmentation with topological consistency. Wang W; Xia Q; Yan Z; Hu Z; Chen Y; Zheng W; Wang X; Nie S; Metaxas D; Zhang S Med Image Anal; 2024 Jan; 91():102999. PubMed ID: 37862866 [TBL] [Abstract][Full Text] [Related]
44. Geodesic Distance Algorithm for Extracting the Ascending Aorta from 3D CT Images. Jang Y; Jung HY; Hong Y; Cho I; Shim H; Chang HJ Comput Math Methods Med; 2016; 2016():4561979. PubMed ID: 26904151 [TBL] [Abstract][Full Text] [Related]
45. Impact of monochromatic coronary computed tomography angiography from single-source dual-energy CT on coronary stenosis quantification. Stehli J; Clerc OF; Fuchs TA; Possner M; Gräni C; Benz DC; Buechel RR; Kaufmann PA J Cardiovasc Comput Tomogr; 2016; 10(2):135-40. PubMed ID: 26754621 [TBL] [Abstract][Full Text] [Related]
47. Limitations of coronary computed tomographic angiography for delineating the lumen and vessel contours of coronary arteries in patients with stable angina. Kim C; Hong SJ; Shin DH; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK Eur Heart J Cardiovasc Imaging; 2015 Dec; 16(12):1358-65. PubMed ID: 25925217 [TBL] [Abstract][Full Text] [Related]
48. Coronary CT angiography derived fractional flow reserve: Methodology and evaluation of a point of care algorithm. Coenen A; Lubbers MM; Kurata A; Kono A; Dedic A; Chelu RG; Dijkshoorn ML; van Geuns RJ; Schoebinger M; Itu L; Sharma P; Nieman K J Cardiovasc Comput Tomogr; 2016; 10(2):105-13. PubMed ID: 26747231 [TBL] [Abstract][Full Text] [Related]
49. A coronary artery segmentation method based on multiscale analysis and region growing. Kerkeni A; Benabdallah A; Manzanera A; Bedoui MH Comput Med Imaging Graph; 2016 Mar; 48():49-61. PubMed ID: 26748040 [TBL] [Abstract][Full Text] [Related]
50. Automated attenuation-based selection of tube voltage and tube current for coronary CT angiography: reduction of radiation exposure versus a BMI-based strategy with an expert investigator. Layritz C; Muschiol G; Flohr T; Bietau C; Marwan M; Schuhbaeck A; Schmid J; Ropers D; Achenbach S; Pflederer T J Cardiovasc Comput Tomogr; 2013; 7(5):303-10. PubMed ID: 24268117 [TBL] [Abstract][Full Text] [Related]
51. [Topological match method in 3D reconstruction of heart vessel]. Lu P; Huang J Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Feb; 28(1):153-6, 162. PubMed ID: 21485204 [TBL] [Abstract][Full Text] [Related]
52. Fused cardiac hybrid imaging with coronary computed tomography angiography and positron emission tomography in patients with complex coronary artery anomalies. Gräni C; Benz DC; Possner M; Clerc OF; Mikulicic F; Vontobel J; Stehli J; Fuchs TA; Pazhenkottil AP; Gaemperli O; Kaufmann PA; Buechel RR Congenit Heart Dis; 2017 Jan; 12(1):49-57. PubMed ID: 27539240 [TBL] [Abstract][Full Text] [Related]
53. A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT. Vembar M; Garcia MJ; Heuscher DJ; Haberl R; Matthews D; Böhme GE; Greenberg NL Med Phys; 2003 Jul; 30(7):1683-93. PubMed ID: 12906185 [TBL] [Abstract][Full Text] [Related]
54. Feasibility of an automatic computer-assisted algorithm for the detection of significant coronary artery disease in patients presenting with acute chest pain. Kang KW; Chang HJ; Shim H; Kim YJ; Choi BW; Yang WI; Shim JY; Ha J; Chung N Eur J Radiol; 2012 Apr; 81(4):e640-6. PubMed ID: 22304980 [TBL] [Abstract][Full Text] [Related]
55. 64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: comparative study using 120 kV. Jun BR; Yong HS; Kang EY; Woo OH; Choi EJ Acta Radiol; 2012 Dec; 53(10):1099-106. PubMed ID: 23034796 [TBL] [Abstract][Full Text] [Related]
57. Comparison of image quality and arterial enhancement with a dedicated coronary CTA protocol versus a triple rule-out coronary CTA protocol. Halpern EJ; Levin DC; Zhang S; Takakuwa KM Acad Radiol; 2009 Sep; 16(9):1039-48. PubMed ID: 19523852 [TBL] [Abstract][Full Text] [Related]
58. TTN: Topological Transformer Network for Automated Coronary Artery Branch Labeling in Cardiac CT Angiography. Zhang Y; Luo G; Wang W; Cao S; Dong S; Yu D; Wang X; Wang K IEEE J Transl Eng Health Med; 2024; 12():129-139. PubMed ID: 38074924 [TBL] [Abstract][Full Text] [Related]
59. Patient-Specific Computational Models of Coronary Arteries Using Monoplane X-Ray Angiograms. Zifan A; Liatsis P Comput Math Methods Med; 2016; 2016():2695962. PubMed ID: 27403203 [TBL] [Abstract][Full Text] [Related]
60. Deep learning segmentation of major vessels in X-ray coronary angiography. Yang S; Kweon J; Roh JH; Lee JH; Kang H; Park LJ; Kim DJ; Yang H; Hur J; Kang DY; Lee PH; Ahn JM; Kang SJ; Park DW; Lee SW; Kim YH; Lee CW; Park SW; Park SJ Sci Rep; 2019 Nov; 9(1):16897. PubMed ID: 31729445 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]