These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 27730142)

  • 1. Comparative assessment of several automatic CPAP devices' responses: a bench test study.
    Isetta V; Navajas D; Montserrat JM; Farré R
    ERJ Open Res; 2015 May; 1(1):. PubMed ID: 27730142
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Novel Approach to Simulate Sleep Apnea Patients for Evaluating Positive Pressure Therapy Devices.
    Isetta V; Montserrat JM; Santano R; Wimms AJ; Ramanan D; Woehrle H; Navajas D; Farré R
    PLoS One; 2016; 11(3):e0151530. PubMed ID: 26978077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pressure-Relief Features of Fixed and Autotitrating Continuous Positive Airway Pressure May Impair Their Efficacy: Evaluation with a Respiratory Bench Model.
    Zhu K; Aouf S; Roisman G; Escourrou P
    J Clin Sleep Med; 2016 Mar; 12(3):385-92. PubMed ID: 26564383
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Response of automatic continuous positive airway pressure devices to different sleep breathing patterns: a bench study.
    Farré R; Montserrat JM; Rigau J; Trepat X; Pinto P; Navajas D
    Am J Respir Crit Care Med; 2002 Aug; 166(4):469-73. PubMed ID: 12186822
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine report.
    Littner M; Hirshkowitz M; Davila D; Anderson WM; Kushida CA; Woodson BT; Johnson SF; Merrill SW;
    Sleep; 2002 Mar; 25(2):143-7. PubMed ID: 11902424
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Characteristics of auto-CPAP devices during the simulation of sleep-related breathing flow patterns].
    Rühle KH; Karweina D; Domanski U; Nilius G
    Pneumologie; 2009 Jul; 63(7):390-8. PubMed ID: 19591085
    [TBL] [Abstract][Full Text] [Related]  

  • 7. All APAPs Are Not Equivalent for the Treatment of Sleep Disordered Breathing: A Bench Evaluation of Eleven Commercially Available Devices.
    Zhu K; Roisman G; Aouf S; Escourrou P
    J Clin Sleep Med; 2015 Jul; 11(7):725-34. PubMed ID: 25766708
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of automated continuous positive airway pressure in children with sleep-related breathing disorders in an attended setting.
    Palombini L; Pelayo R; Guilleminault C
    Pediatrics; 2004 May; 113(5):e412-7. PubMed ID: 15121982
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bench model to simulate upper airway obstruction for analyzing automatic continuous positive airway pressure devices.
    Rigau J; Montserrat JM; Wöhrle H; Plattner D; Schwaibold M; Navajas D; Farré R
    Chest; 2006 Aug; 130(2):350-61. PubMed ID: 16899832
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bench evaluation of flow limitation detection by automated continuous positive airway pressure devices.
    Lofaso F; Desmarais G; Leroux K; Zalc V; Fodil R; Isabey D; Louis B
    Chest; 2006 Aug; 130(2):343-9. PubMed ID: 16899831
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Randomised controlled trial of auto-adjusting positive airway pressure in morbidly obese patients requiring high therapeutic pressure delivery.
    Bakker J; Campbell A; Neill A
    J Sleep Res; 2011 Mar; 20(1 Pt 2):233-40. PubMed ID: 20545835
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.
    Damiani MF; Quaranta VN; Tedeschi E; Drigo R; Ranieri T; Carratù P; Resta O
    Respirology; 2013 Aug; 18(6):968-73. PubMed ID: 23600534
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.
    Nolan GM; Ryan S; O'connor TM; McNicholas WT
    Eur Respir J; 2006 Jul; 28(1):159-64. PubMed ID: 16571610
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea. An American Academy of Sleep Medicine review.
    Berry RB; Parish JM; Hartse KM
    Sleep; 2002 Mar; 25(2):148-73. PubMed ID: 11902425
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of air leak on the performance of auto-PAP devices: a bench study.
    Coller D; Stanley D; Parthasarathy S
    Sleep Breath; 2005 Dec; 9(4):167-75. PubMed ID: 16273421
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of flow- vs impedance-guided autoadjustable continuous positive airway pressure: a randomized cross-over trial.
    Pevernagie DA; Proot PM; Hertegonne KB; Neyens MC; Hoornaert KP; Pauwels RA
    Chest; 2004 Jul; 126(1):25-30. PubMed ID: 15249438
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A sleep laboratory evaluation of an automatic positive airway pressure system for treatment of obstructive sleep apnea.
    Behbehani K; Yen FC; Lucas EA; Burk JR
    Sleep; 1998 Aug; 21(5):485-91. PubMed ID: 9703588
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acute effects of autoadjusting and fixed continuous positive airway pressure treatments on cardiorespiratory coupling in obese patients with obstructive sleep apnea.
    Patruno V; Tobaldini E; Bianchi AM; Mendez MO; Coletti O; Costantino G; Montano N
    Eur J Intern Med; 2014 Feb; 25(2):164-8. PubMed ID: 24373628
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous positive airway pressure: new generations.
    Roux FJ; Hilbert J
    Clin Chest Med; 2003 Jun; 24(2):315-42. PubMed ID: 12800787
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Automatic positive airway pressure in titration and treatment of the obstructive sleep apnea syndrome].
    Randerath WJ
    Pneumologie; 2007 Apr; 61(4):228-32. PubMed ID: 17455137
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.