These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
215 related articles for article (PubMed ID: 27734817)
21. A Portable Smartphone-Based Laryngoscope System for High-Speed Vocal Cord Imaging of Patients With Throat Disorders: Instrument Validation Study. Kim Y; Oh J; Choi SH; Jung A; Lee JG; Lee YS; Kim JK JMIR Mhealth Uhealth; 2021 Jun; 9(6):e25816. PubMed ID: 34142978 [TBL] [Abstract][Full Text] [Related]
22. Quantitative assessment of videolaryngostroboscopic images in patients with glottic pathologies. Niebudek-Bogusz E; Kopczynski B; Strumillo P; Morawska J; Wiktorowicz J; Sliwinska-Kowalska M Logoped Phoniatr Vocol; 2017 Jul; 42(2):73-83. PubMed ID: 27132636 [TBL] [Abstract][Full Text] [Related]
23. Objective measures of laryngeal imaging: what have we learned since Dr. Paul Moore. Woo P J Voice; 2014 Jan; 28(1):69-81. PubMed ID: 24094798 [TBL] [Abstract][Full Text] [Related]
24. Vocal Fold Vibration in Vocal Fold Atrophy: Quantitative Analysis With High-Speed Digital Imaging. Yamauchi A; Yokonishi H; Imagawa H; Sakakibara K; Nito T; Tayama N; Yamasoba T J Voice; 2015 Nov; 29(6):755-62. PubMed ID: 25737475 [TBL] [Abstract][Full Text] [Related]
25. Real-time Simultaneous DKG and 2D DKG Using High-speed Digital Camera. Kang DH; Wang SG; Park HJ; Lee JC; Jeon GR; Choi IS; Kim SJ; Shin BJ J Voice; 2017 Mar; 31(2):247.e1-247.e7. PubMed ID: 27839706 [TBL] [Abstract][Full Text] [Related]
26. Multiparametric analysis of vocal fold vibrations in healthy and disordered voices in high-speed imaging. Inwald EC; Döllinger M; Schuster M; Eysholdt U; Bohr C J Voice; 2011 Sep; 25(5):576-90. PubMed ID: 20728308 [TBL] [Abstract][Full Text] [Related]
27. Relationship of Various Open Quotients With Acoustic Property, Phonation Types, Fundamental Frequency, and Intensity. Yokonishi H; Imagawa H; Sakakibara K; Yamauchi A; Nito T; Yamasoba T; Tayama N J Voice; 2016 Mar; 30(2):145-57. PubMed ID: 25953586 [TBL] [Abstract][Full Text] [Related]
28. Parameters of the assessment of voice quality and clinical manifestation of rheumatoid arthritis. Kosztyła-Hojna B; Moskal D; Kuryliszyn-Moskal A Adv Med Sci; 2015 Sep; 60(2):321-8. PubMed ID: 26197080 [TBL] [Abstract][Full Text] [Related]
29. [The videostrobokymography in phoniatric practice]. Szkiełkowska A; Miaśkiewicz B; Krasnodębska P; Uszyńska-Tuzinek M; Skarżyński H Otolaryngol Pol; 2012; 66(3):214-8. PubMed ID: 22748684 [TBL] [Abstract][Full Text] [Related]
30. Real-time dual visualization of two different modalities for the evaluation of vocal fold vibration - Laryngeal videoendoscopy and 2D scanning videokymography: Preliminary report. Kim GH; Wang SG; Lee BJ; Park HJ; Kim YC; Kim HS; Sohn KT; Kwon SB Auris Nasus Larynx; 2017 Apr; 44(2):174-181. PubMed ID: 27421819 [TBL] [Abstract][Full Text] [Related]
31. The Effects of Humming on the Prephonatory Vocal Fold Motions Under High-Speed Digital Imaging in Nondysphonic Speakers. Iwahashi T; Ogawa M; Hosokawa K; Kato C; Inohara H J Voice; 2017 May; 31(3):291-299. PubMed ID: 27726905 [TBL] [Abstract][Full Text] [Related]
32. High-speed Imaging of Vocal Fold Vibration Onset Delay: Normal Versus Abnormal. Woo P J Voice; 2017 May; 31(3):307-312. PubMed ID: 27836428 [TBL] [Abstract][Full Text] [Related]
33. A portable high-speed camera system for vocal fold examinations. Hertegård S; Larsson H J Voice; 2014 Nov; 28(6):681-7. PubMed ID: 25008381 [TBL] [Abstract][Full Text] [Related]
34. Analysis of voice quality parameters in patients with vestibular voice. Kosztyła-Hojna B; Łobaczuk-Sitnik A; Zdrojkowski M; Duchnowska E; Moskal-Jasińska D; Kraszewska A; Twarowska A; Biszewska J Otolaryngol Pol; 2019 Mar; 73(3):11-15. PubMed ID: 31249146 [TBL] [Abstract][Full Text] [Related]
35. Comparative analysis of vocal fold vibration using high-speed videoendoscopy and digital kymography. Baravieira PB; Brasolotto AG; Hachiya A; Takahashi-Ramos MT; Tsuji DH; Montagnoli AN J Voice; 2014 Sep; 28(5):603-7. PubMed ID: 24726330 [TBL] [Abstract][Full Text] [Related]
37. Spectral analysis of digital kymography in normal adult vocal fold vibration. Chen W; Woo P; Murry T J Voice; 2014 May; 28(3):356-61. PubMed ID: 24412039 [TBL] [Abstract][Full Text] [Related]
38. The First Application of the Two-Dimensional Scanning Videokymography in Excised Canine Larynx Model. Wang SG; Park HJ; Cho JK; Jang JY; Lee WY; Lee BJ; Lee JC; Cha W J Voice; 2016 Jan; 30(1):1-4. PubMed ID: 26296852 [TBL] [Abstract][Full Text] [Related]
39. Vocal-fold vibration of patients with Reinke's edema observed using high-speed digital imaging. Watanabe T; Kaneko K; Sakaguchi K; Takahashi H Auris Nasus Larynx; 2016 Dec; 43(6):654-7. PubMed ID: 26976546 [TBL] [Abstract][Full Text] [Related]
40. Imaging and Analysis of Human Vocal Fold Vibration Using Two-Dimensional (2D) Scanning Videokymography. Park HJ; Cha W; Kim GH; Jeon GR; Lee BJ; Shin BJ; Choi YG; Wang SG J Voice; 2016 May; 30(3):345-53. PubMed ID: 26239969 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]