BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 27739486)

  • 1. Fabrication of a silver particle-integrated silicone polymer-covered metal stent against sludge and biofilm formation and stent-induced tissue inflammation.
    Lee TH; Jang BS; Jung MK; Pack CG; Choi JH; Park DH
    Sci Rep; 2016 Oct; 6():35446. PubMed ID: 27739486
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Safety and efficacy of a metal stent covered with a silicone membrane containing integrated silver particles in preventing biofilm and sludge formation in endoscopic drainage of malignant biliary obstruction: a phase 2 pilot study.
    Lee TH; Jung MK; Kim TK; Pack CG; Park YK; Kim SO; Park DH
    Gastrointest Endosc; 2019 Oct; 90(4):663-672.e2. PubMed ID: 31220446
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial.
    Kitano M; Yamashita Y; Tanaka K; Konishi H; Yazumi S; Nakai Y; Nishiyama O; Uehara H; Mitoro A; Sanuki T; Takaoka M; Koshitani T; Arisaka Y; Shiba M; Hoki N; Sato H; Sasaki Y; Sato M; Hasegawa K; Kawabata H; Okabe Y; Mukai H
    Am J Gastroenterol; 2013 Nov; 108(11):1713-22. PubMed ID: 24042190
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Localized Photodynamic Therapy Using a Chlorin e6-Embedded Silicone-Covered Self-Expandable Metallic Stent as a Palliative Treatment for Malignant Esophageal Strictures.
    Ryu DS; Kim JW; Lee H; Eo SJ; Kim SH; Noh JH; Kim Y; Kang S; Na K; Park JH; Kim DH
    ACS Biomater Sci Eng; 2024 Mar; 10(3):1869-1879. PubMed ID: 38291563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel biliary stent coated with silver nanoparticles prolongs the unobstructed period and survival via anti-bacterial activity.
    Yang F; Ren Z; Chai Q; Cui G; Jiang L; Chen H; Feng Z; Chen X; Ji J; Zhou L; Wang W; Zheng S
    Sci Rep; 2016 Feb; 6():21714. PubMed ID: 26883081
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Silicone-covered metal stents: an in vitro evaluation for biofilm formation and patency.
    Tsang TK; Pollack J; Chodash HB
    Dig Dis Sci; 1999 Sep; 44(9):1780-5. PubMed ID: 10505714
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Silicone Stent Versus Fully Covered Metallic Stent in Malignant Central Airway Stenosis.
    Ortiz-Comino RM; Morales A; López-Lisbona R; Cubero N; Diez-Ferrer M; Tebé C; Rosell A;
    Ann Thorac Surg; 2021 Jan; 111(1):283-289. PubMed ID: 32589886
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Covered vs. uncovered self-expandable metal stents for malignant distal biliary strictures: a systematic review and meta-analysis.
    Tringali A; Hassan C; Rota M; Rossi M; Mutignani M; Aabakken L
    Endoscopy; 2018 Jun; 50(6):631-641. PubMed ID: 29342491
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Self-expanding covered metallic stents as a transition to silicone stent implantation in management of severe post-tuberculosis bronchial stenosis.
    Zhou ZQ; Feng JX; Chen Y; Su ZQ; Zhong CH; Chen XB; Tang CL; Huang JR; Li SY
    Ther Adv Respir Dis; 2021; 15():17534666211019564. PubMed ID: 34044660
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Local hyperthermia mediated by gold nanoparticle-integrated silicone-covered stent: feasibility and tissue response in a rat esophageal model.
    Tsauo J; Liu Y; Zhang X; Fu Y; Zhao H; Gong T; Li J; Li X
    Eur Radiol Exp; 2024 Apr; 8(1):40. PubMed ID: 38565836
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Antibacterial Properties of Silicone Membranes after a Simple Two-Step Immersion Process in Iodine and Silver Nitrate Solutions.
    Aoki S; Yamakawa K; Kubo K; Takeshita J; Takeuchi M; Nobuoka Y; Wada R; Kikuchi M; Sawai J
    Biocontrol Sci; 2018; 23(3):97-105. PubMed ID: 30249968
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tapered self-expandable metallic stent optimized for Eustachian tube morphology in a porcine ET model.
    Kang JM; Kim SH; Ryu DS; Park Y; Won DS; Kim JW; Zeng CH; Kang WS; Park JH; Park HJ
    Sci Rep; 2022 Nov; 12(1):20290. PubMed ID: 36434004
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of bipolar radiofrequency ablation for occluded self-expandable metal stents in the bile duct: in vivo and in vitro study.
    Yoon WJ; Kim YT; Daglilar ES; Mino-Kenudson M; Brugge WR
    Endoscopy; 2015 Dec; 47(12):1167-70. PubMed ID: 26111360
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metallic Stent Mesh Coated with Silver Nanoparticles Suppresses Stent-Induced Tissue Hyperplasia and Biliary Sludge in the Rabbit Extrahepatic Bile Duct.
    Park W; Kim KY; Kang JM; Ryu DS; Kim DH; Song HY; Kim SH; Lee SO; Park JH
    Pharmaceutics; 2020 Jun; 12(6):. PubMed ID: 32560473
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.
    Hori Y; Naitoh I; Hayashi K; Ban T; Natsume M; Okumura F; Nakazawa T; Takada H; Hirano A; Jinno N; Togawa S; Ando T; Kataoka H; Joh T
    Surg Endosc; 2017 Oct; 31(10):4165-4173. PubMed ID: 28281116
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cefotaxime-eluting covered self-expandable stents in a canine biliary model: scanning electron microscopic study of biofilm formation.
    Gwon DI; Lee SS; Kim EY
    Acta Radiol; 2012 Dec; 53(10):1127-32. PubMed ID: 23034797
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Partially covered metal stents have longer patency than uncovered and fully covered metal stents in the management of distal malignant biliary obstruction: a retrospective study.
    Yokota Y; Fukasawa M; Takano S; Kadokura M; Shindo H; Takahashi E; Hirose S; Kawakami S; Fukasawa Y; Sato T; Enomoto N
    BMC Gastroenterol; 2017 Oct; 17(1):105. PubMed ID: 29020933
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Management of acute cholangitis as a result of occlusion from a self-expandable metallic stent in patients with malignant distal and hilar biliary obstructions.
    Shiomi H; Matsumoto K; Isayama H
    Dig Endosc; 2017 Apr; 29 Suppl 2():88-93. PubMed ID: 28425663
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Silver nanoparticles synthesized and coated with pectin: An ideal compromise for anti-bacterial and anti-biofilm action combined with wound-healing properties.
    Pallavicini P; Arciola CR; Bertoglio F; Curtosi S; Dacarro G; D'Agostino A; Ferrari F; Merli D; Milanese C; Rossi S; Taglietti A; Tenci M; Visai L
    J Colloid Interface Sci; 2017 Jul; 498():271-281. PubMed ID: 28342310
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Difficult removal of fully covered self expandable metal stents (SEMS) for benign biliary strictures: the "SEMS in SEMS" technique.
    Tringali A; Blero D; Boškoski I; Familiari P; Perri V; Devière J; Costamagna G
    Dig Liver Dis; 2014 Jun; 46(6):568-71. PubMed ID: 24661988
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.