3. Hypothermic Cardiopulmonary Bypass Weaning and Prolonged Postoperative Rewarming in a Patient With Intraoperative Oxygenator Thrombosis. Grant I; Breidenstein M; Parsee A; Krumholz C; Martin J J Cardiothorac Vasc Anesth; 2018 Aug; 32(4):1851-1854. PubMed ID: 29221982 [No Abstract] [Full Text] [Related]
4. Hypoxemia after intraluminal oxygen line obstruction during cardiopulmonary bypass. Robblee JA; Crosby E; Keon WJ Ann Thorac Surg; 1989 Oct; 48(4):575-6. PubMed ID: 2508584 [TBL] [Abstract][Full Text] [Related]
5. Severe hypoxaemia during cardiopulmonary bypass. Warren SJ; Miller CD Anaesthesia; 1986 Dec; 41(12):1266-7. PubMed ID: 3812957 [No Abstract] [Full Text] [Related]
6. Displaced adjustable pressure limiting valve leaflet leading to partial expiratory obstruction in a cat. West E; Halil J Vet Anaesth Analg; 2019 Jan; 46(1):143-145. PubMed ID: 30528343 [No Abstract] [Full Text] [Related]
7. Ventilatory failures with the Datex-Ohmeda 7900 SmartVent. Cantillo J; Domsky R; Gratz I; Goldberg ME Anesthesiology; 2002 Mar; 96(3):766-8. PubMed ID: 11873058 [No Abstract] [Full Text] [Related]
8. [Critical incident in relation to an anti-pollution system]. Muñoz-Ramón JM; de la Cruz MT; Criado A Rev Esp Anestesiol Reanim; 1994; 41(1):43. PubMed ID: 8016432 [No Abstract] [Full Text] [Related]
9. [Perioperative safety and anesthesiologic monitoring]. Stober HD Z Arztl Fortbild (Jena); 1994 Feb; 88(2):105-10. PubMed ID: 8147016 [No Abstract] [Full Text] [Related]
10. Alarm-enhancement systems for ventilators: problems with physiologic monitoring interfaces. Health Devices; 2004 Oct; 33(10):354-5. PubMed ID: 15559260 [TBL] [Abstract][Full Text] [Related]
11. Failure of low pressure alarm associated with the use of a humidifier. Slee TA; Pavlin EG Anesthesiology; 1988 Nov; 69(5):791-3. PubMed ID: 3189932 [No Abstract] [Full Text] [Related]
12. Monitoring of pressure, flow, and volume during mechanical ventilation. Tobin MJ Respir Care; 1992 Sep; 37(9):1081-96. PubMed ID: 10145702 [No Abstract] [Full Text] [Related]
13. High end-expiratory airway pressures caused by internal obstruction of the Draeger Apollo® scavenger system that is not detected by the workstation self-test and visual inspection. Joyal JJ; Vannucci A; Kangrga I Anesthesiology; 2012 May; 116(5):1162-4; discussion 1164-6. PubMed ID: 22531265 [No Abstract] [Full Text] [Related]
15. [Selective intubation through a rigid bronchoscope]. de la Linde CM; López MI; Ortiz JM; Pulido S Rev Esp Anestesiol Reanim; 2005 Oct; 52(8):509-11. PubMed ID: 16281752 [No Abstract] [Full Text] [Related]
16. Take precautions with audible alarms on ventilators. Love LC; Millin CJ; Kerns CD Nursing; 2011 Sep; 41(9):65. PubMed ID: 21844779 [No Abstract] [Full Text] [Related]
17. [Hierarchy of monitors in artificial ventilation]. Frankenberger H Biomed Tech (Berl); 1990; 35 Suppl 3():190-1. PubMed ID: 2078691 [No Abstract] [Full Text] [Related]
18. Intraoperative subarachnoid haemorrhage associated with a reduction in bispectral index during cardiopulmonary bypass. Lee JW; Choi JH; Kim Y; Kim MK Anaesth Intensive Care; 2016 Nov; 44(6):786-787. PubMed ID: 27832575 [No Abstract] [Full Text] [Related]