175 related articles for article (PubMed ID: 27744077)
1. Controlled Suction with Venous Catheter Irrigation in Neurosurgery: A Cost Effective Technique.
Panigrahi M; Kumari M; Vooturi S
World Neurosurg; 2017 Jan; 97():284-286. PubMed ID: 27744077
[TBL] [Abstract][Full Text] [Related]
2. An Irrigation Suction System Using a Pressurized Fluid High-Flow Pump System in Comparison with a Standard Cuff Pressure System: Technical Note.
Murai Y; Matano F; Toda S; Kobayashi S; Morita A
J Neurol Surg A Cent Eur Neurosurg; 2016 May; 77(3):264-8. PubMed ID: 25915502
[TBL] [Abstract][Full Text] [Related]
3. A continuous microneurosurgical irrigation and suction system: technical note.
Johnson JP; Becker DP
Neurosurgery; 1996 Aug; 39(2):409-11. PubMed ID: 8832684
[TBL] [Abstract][Full Text] [Related]
4. Irrigation-suction straw sheath system for a rigid endoscope during endonasal endoscopic pituitary surgery.
Kubo S; Kikawada T; Hasegawa H; Tominaga S; Yoshimine T
Minim Invasive Neurosurg; 2005 Dec; 48(6):373-5. PubMed ID: 16432789
[TBL] [Abstract][Full Text] [Related]
5. A Simple Innovative Alternative for Irrigation-Aspiration in Orthopedic Infections Using a Foley Catheter.
Kamath J; Jayasheelan N; Bansal A; Danda R; Muppala G
Surg Infect (Larchmt); 2016 Dec; 17(6):745-748. PubMed ID: 27802106
[TBL] [Abstract][Full Text] [Related]
6. An inexpensive semiautomated irrigation/aspiration system.
Sheets JH
J Am Intraocul Implant Soc; 1985 Jan; 11(1):71-2. PubMed ID: 3967997
[TBL] [Abstract][Full Text] [Related]
7. Affordable self-regulating irrigation device for microsurgery using readily available malleable wire and a Silastic tube: a technical note.
Chung Y; Lee SH; Ryu J; Lee JH; Choi SK
Acta Neurochir (Wien); 2017 Dec; 159(12):2351-2354. PubMed ID: 28905154
[TBL] [Abstract][Full Text] [Related]
8. Pressure-controlled dual irrigation-suction system for microneurosurgery: technical note.
Okada Y; Kawamata T; Kawashima A; Yamaguchi K; Hori T
Neurosurgery; 2009 Sep; 65(3):E625; discussion E625. PubMed ID: 19687671
[TBL] [Abstract][Full Text] [Related]
9. Balanced irrigation-suction technique with a multifunctional suction cannula and its application for intraoperative hemorrhage in endoscopic evacuation of intracerebral hematomas: technical note.
Nagasaka T; Tsugeno M; Ikeda H; Okamoto T; Takagawa Y; Inao S; Wakabayashi T
Neurosurgery; 2009 Oct; 65(4):E826-7; discussion E827. PubMed ID: 19834365
[TBL] [Abstract][Full Text] [Related]
10. A simple device for controlling suction force in neurosurgical operations.
Papadopoulos SM; McGillicuddy JE
Neurosurgery; 1989 Oct; 25(4):662-3. PubMed ID: 2797406
[TBL] [Abstract][Full Text] [Related]
11. A simple irrigator-aspirator cannula for laparoscopy: the Stewart system.
Marshburn PB; Hulka JF
Obstet Gynecol; 1990 Mar; 75(3 Pt 1):458-60. PubMed ID: 2137577
[TBL] [Abstract][Full Text] [Related]
12. Controlled trial of a continuous irrigation suction catheter vs conventional intermittent suction catheter in clearing bronchial secretions from ventilated patients.
Isea JO; Poyant D; O'Donnell C; Faling LJ; Karlinsky J; Celli BR
Chest; 1993 Apr; 103(4):1227-30. PubMed ID: 8131470
[TBL] [Abstract][Full Text] [Related]
13. Modified Endoscopic Diving Technique without the Traditional Irrigation System in Endoscopic Cranial Base Surgery: Technical Note.
Ceraudo M; Anania P; Prior A; Rossi DC; Zona G
World Neurosurg; 2019 Jul; 127():146-149. PubMed ID: 30954749
[TBL] [Abstract][Full Text] [Related]
14. [Extendable Cords to Prevent Tumbling of a Suction Device during Craniotomy].
Shimizu S; Mochizuki T; Osawa S; Sekiguchi T; Koizumi H; Kumabe T
No Shinkei Geka; 2016 Feb; 44(2):111-3. PubMed ID: 26856263
[TBL] [Abstract][Full Text] [Related]
15. Thermal hazards in mastoid surgery: an evaluation of instruments and irrigation techniques.
Keim RJ; Erdreich J; Love TJ
Otolaryngol Head Neck Surg (1979); 1979; 87(4):472-8. PubMed ID: 503508
[TBL] [Abstract][Full Text] [Related]
16. Conventional wound management versus a closed suction irrigation method for infected laparotomy wound--a comparative study.
Zhen ZJ; Lai EC; Lee QH; Chen HW; Lau WY; Wang FJ
Int J Surg; 2011; 9(5):378-81. PubMed ID: 21371577
[TBL] [Abstract][Full Text] [Related]
17. A Novel Endoscopic Catheter for "Laparoscopy-Like" Irrigation and Suction: Its Research and Development Process and Clinical Evaluation.
Miyazaki Y; Nakajima K; Hosaka M; Ban N; Takahashi T; Yamasaki M; Miyata H; Kurokawa Y; Takiguchi S; Mori M; Doki Y
J Laparoendosc Adv Surg Tech A; 2016 Dec; 26(12):943-949. PubMed ID: 27428360
[TBL] [Abstract][Full Text] [Related]
18. Spray-irrigation system attached to high-speed drills for simultaneous prevention of local heating and preservation of a clear operative field in spinal surgery.
Sasaki M; Morris S; Goto T; Iwatsuki K; Yoshimine T
Neurol Med Chir (Tokyo); 2010; 50(10):900-4. PubMed ID: 21030801
[TBL] [Abstract][Full Text] [Related]
19. [Use of suction drainage with irrigation in peritoneal cavity drainage].
Harustiak S; Moravec R; Siska K
Bratisl Lek Listy; 1982 Dec; 78(6):700-5. PubMed ID: 7150991
[No Abstract] [Full Text] [Related]
20. Performance of indirect embolectomy aided by a new developed flush-suction catheter system. Forty-seven experimental embolectomy procedures in test animals.
Vicol C; Dalichau H; Köhler J; Schunk O; Fischer G; Friedel M; Stevens K; Leyen S
J Cardiovasc Surg (Torino); 1994 Jun; 35(3):193-200. PubMed ID: 8040166
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]