BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 27744664)

  • 1. Endoscopic Management of Anastomotic Strictures after Liver Transplantation.
    Lee DW; Jo HH; Abdullah J; Kahaleh M
    Clin Endosc; 2016 Sep; 49(5):457-461. PubMed ID: 27744664
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Management of liver transplantation biliary stricture: Results from a tertiary hospital.
    Martins FP; Kahaleh M; Ferrari AP
    World J Gastrointest Endosc; 2015 Jun; 7(7):747-57. PubMed ID: 26140103
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endoscopic treatment of anastomotic biliary stricture after adult deceased donor liver transplantation with multiple plastic stents versus self-expandable metal stents: a systematic review and meta-analysis.
    Landi F; de'Angelis N; Sepulveda A; Martínez-Pérez A; Sobhani I; Laurent A; Soubrane O
    Transpl Int; 2018 Feb; 31(2):131-151. PubMed ID: 29090502
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Endo-therapies for biliary duct-to-duct anastomotic stricture after liver transplantation: Outcomes of a nationwide survey.
    Cantù P; Tarantino I; Baldan A; Mutignani M; Tringali A; Lombardi G; Cerofolini A; Di Sario A; Catalano G; Bertani H; Ghinolfi D; Boarino V; Masci E; Bulajic M; Pisani A; Fantin A; Ligresti D; Barresi L; Traina M; Ravelli P; Forti E; Barbaro F; Costamagna G; Rodella L; Maroni L; Salizzoni M; Conigliaro R; Filipponi F; Merighi A; Staiano T; Monteleone M; Mazzaferro V; Zucchi E; Zilli M; Nadal E; Rosa R; Santi G; Parzanese I; De Carlis L; Donato MF; Lampertico P; Maggi U; Caccamo L; Rossi G; Vecchi M; Penagini R
    Liver Int; 2019 Jul; 39(7):1355-1362. PubMed ID: 30500104
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Managing the post-liver transplantation anastomotic biliary stricture: multiple plastic versus metal stents: a systematic review.
    Kao D; Zepeda-Gomez S; Tandon P; Bain VG
    Gastrointest Endosc; 2013 May; 77(5):679-91. PubMed ID: 23473000
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Success and complications of an intra-ductal fully covered self-expanding metal stent (ID-FCSEMS) to treat anastomotic biliary strictures (AS) after orthotopic liver transplantation (OLT).
    Aepli P; St John A; Gupta S; Hourigan LF; Vaughan R; Efthymiou M; Kaffes A
    Surg Endosc; 2017 Apr; 31(4):1558-1563. PubMed ID: 27572066
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical efficacy of anti-migration features in fully covered metallic stents for anastomotic biliary strictures after liver transplantation: comparison of conventional and anti-migration stents.
    Bordaçahar B; Perdigao F; Leblanc S; Barret M; Duchmann JC; Guillaumot MA; Chaussade S; Scatton O; Prat F
    Gastrointest Endosc; 2018 Oct; 88(4):655-664. PubMed ID: 30003877
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Endoscopic treatment of post-liver transplantation anastomotic biliary stricture: systematic review and meta-analysis.
    Nacif LS; Bernardo WM; Bernardo L; Andraus W; Torres L; Chaib E; D'Albuquerque LC; Maluf-Filho F
    Arq Gastroenterol; 2014; 51(3):240-9. PubMed ID: 25296086
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Treatment of Biliary Stricture After Live Donor Liver Transplantation With Combined Metal and Plastic Stent Insertion: A Feasibility and Safety Study.
    Parlak E; Koksal AS; Eminler AT; Toka B; Uslan MI
    Transplantation; 2017 Aug; 101(8):1852-1858. PubMed ID: 28319567
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A prospective group sequential study evaluating a new type of fully covered self-expandable metal stent for the treatment of benign biliary strictures (with video).
    Poley JW; Cahen DL; Metselaar HJ; van Buuren HR; Kazemier G; van Eijck CH; Haringsma J; Kuipers EJ; Bruno MJ
    Gastrointest Endosc; 2012 Apr; 75(4):783-9. PubMed ID: 22325806
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of high risk factors for endoscopic retrograde cholangiopancreatography biliary metallic stenting after malignant duodenal stricture SEMS implantation.
    Yao JF; Zhang L; Wu H
    J Biol Regul Homeost Agents; 2016; 30(3):743-748. PubMed ID: 27655491
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term outcomes of endoscopic treatment for duct-to-duct anastomotic strictures after living donor liver transplantation.
    Sato T; Kogure H; Nakai Y; Hamada T; Takahara N; Mizuno S; Kawaguchi Y; Akamatsu N; Kaneko J; Hasegawa K; Tada M; Tsujino T; Isayama H; Koike K
    Liver Int; 2019 Oct; 39(10):1954-1963. PubMed ID: 31436017
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fully covered self-expandable metal stents to dilate persistent pancreatic strictures in chronic pancreatitis: long-term follow-up from a prospective study.
    Tringali A; Vadalà di Prampero SF; Landi R; Bove V; Familiari P; Hamanaka J; Attili F; Costamagna G
    Gastrointest Endosc; 2018 Dec; 88(6):939-946. PubMed ID: 30142349
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metal versus plastic stents for anastomotic biliary strictures after liver transplantation: a randomized controlled trial.
    Martins FP; De Paulo GA; Contini MLC; Ferrari AP
    Gastrointest Endosc; 2018 Jan; 87(1):131.e1-131.e13. PubMed ID: 28455159
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endoscopic Management of Post-Liver Transplantation Biliary Strictures With the Use of Fully Covered Metallic Stents.
    Jiménez-Pérez M; Melgar Simón JM; Durán Campos A; González Grande R; Rodrigo López JM; Manteca González R
    Transplant Proc; 2016 Sep; 48(7):2510-2514. PubMed ID: 27742337
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Management of anastomotic biliary stricture after liver transplantation: metal versus plastic stent.
    Facciorusso A; Rosca EC; Ashimi A; Ugoeze KC; Pathak U; Infante V; Muscatiello N
    Ann Gastroenterol; 2018; 31(6):728-734. PubMed ID: 30386124
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of Fully Covered Self-Expandable Metallic Stents with and without Antimigration Waist Versus Repeated Plastic Biliary Stent Placement in Management of Anastomotic Biliary Strictures After Orthotopic Liver Transplantation.
    Zeair S; Butkiewicz F; Butkiewicz J; Stasiuk R
    Ann Transplant; 2017 Dec; 22():719-724. PubMed ID: 29192137
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endoscopic management of biliary complications after liver transplantation: An evidence-based review.
    Macías-Gómez C; Dumonceau JM
    World J Gastrointest Endosc; 2015 Jun; 7(6):606-16. PubMed ID: 26078829
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multiple plastic versus fully covered metal stents for managing post-liver transplantation anastomotic biliary strictures: a meta-analysis of randomized controlled trials.
    Tringali A; Tarantino I; Barresi L; Traina M; Bonato G; Cintolo M; Hassan C; Mutignani M; Adler DG
    Ann Gastroenterol; 2019; 32(4):407-415. PubMed ID: 31263364
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Self-Expandable Metallic Stent Is More Cost Efficient Than Plastic Stent in Treating Anastomotic Biliary Stricture.
    Jang S; Stevens T; Lopez R; Chahal P; Bhatt A; Sanaka M; Vargo JJ
    Dig Dis Sci; 2020 Feb; 65(2):600-608. PubMed ID: 31104197
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.