These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 27745873)

  • 1. Stress shielding in periprosthetic bone following a total knee replacement: Effects of implant material, design and alignment.
    Zhang QH; Cossey A; Tong J
    Med Eng Phys; 2016 Dec; 38(12):1481-1488. PubMed ID: 27745873
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of varus/valgus malalignment on bone strains in the proximal tibia after TKR: an explicit finite element study.
    Perillo-Marcone A; Taylor M
    J Biomech Eng; 2007 Feb; 129(1):1-11. PubMed ID: 17227092
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of tibial component malalignment on bone strain in revision total knee replacement.
    Rastetter BR; Wright SJ; Gheduzzi S; Miles AW; Clift SE
    Proc Inst Mech Eng H; 2016 Jun; 230(6):561-8. PubMed ID: 27006420
    [TBL] [Abstract][Full Text] [Related]  

  • 4. All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.
    Brihault J; Navacchia A; Pianigiani S; Labey L; De Corte R; Pascale V; Innocenti B
    Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2550-9. PubMed ID: 25957612
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements.
    Au AG; James Raso V; Liggins AB; Amirfazli A
    J Biomech; 2007; 40(6):1410-6. PubMed ID: 16846605
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.
    Thompson SM; Yohuno D; Bradley WN; Crocombe AD
    Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2560-6. PubMed ID: 26694487
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Does a PEEK Femoral TKA Implant Preserve Intact Femoral Surface Strains Compared With CoCr? A Preliminary Laboratory Study.
    Rankin KE; Dickinson AS; Briscoe A; Browne M
    Clin Orthop Relat Res; 2016 Nov; 474(11):2405-2413. PubMed ID: 27020431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of malalignment on proximal tibial strain in fixed-bearing unicompartmental knee arthroplasty: A comparison between metal-backed and all-polyethylene components using a validated finite element model.
    Danese I; Pankaj P; Scott CEH
    Bone Joint Res; 2019 Feb; 8(2):55-64. PubMed ID: 30915211
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Malalignment of the total ankle replacement increases peak contact stresses on the bone-implant interface: a finite element analysis.
    van Hoogstraten SWG; Hermus J; Loenen ACY; Arts JJ; van Rietbergen B
    BMC Musculoskelet Disord; 2022 May; 23(1):463. PubMed ID: 35581630
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Finite-Element Study of Metal Backing and Tibial Resection Depth in a Composite Tibia Following Total Knee Arthroplasty.
    Tokunaga S; Rogge RD; Small SR; Berend ME; Ritter MA
    J Biomech Eng; 2016 Apr; 138(4):041001. PubMed ID: 26810930
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical Effects of Different Varus and Valgus Alignments in Medial Unicompartmental Knee Arthroplasty.
    Innocenti B; Pianigiani S; Ramundo G; Thienpont E
    J Arthroplasty; 2016 Dec; 31(12):2685-2691. PubMed ID: 27519962
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method.
    Apostolopoulos V; Boháč P; Marcián P; Nachtnebl L; Mahdal M; Pazourek L; Tomáš T
    J Orthop Surg Res; 2024 Feb; 19(1):153. PubMed ID: 38396020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of limb alignment on mediolateral loading in total knee replacement: in vivo measurements in five patients.
    Halder A; Kutzner I; Graichen F; Heinlein B; Beier A; Bergmann G
    J Bone Joint Surg Am; 2012 Jun; 94(11):1023-9. PubMed ID: 22637208
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method.
    Apostolopoulos V; Tomáš T; Boháč P; Marcián P; Mahdal M; Valoušek T; Janíček P; Nachtnebl L
    Comput Methods Programs Biomed; 2022 Jun; 220():106834. PubMed ID: 35490458
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A combined FE-hybrid MCDM framework for improving the performance of the conical stem tibial design for TAR with the addition of pegs.
    Jyoti ; Ghosh R
    Comput Methods Programs Biomed; 2023 Jul; 237():107574. PubMed ID: 37148636
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of implant orientation and implant material on tibia bone strain, implant-bone micromotion, contact pressure, and wear depth due to total ankle replacement.
    Mondal S; Ghosh R
    Proc Inst Mech Eng H; 2019 Mar; 233(3):318-331. PubMed ID: 30663509
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement.
    Chong DY; Hansen UN; van der Venne R; Verdonschot N; Amis AA
    J Biomech; 2011 Mar; 44(5):948-54. PubMed ID: 21236431
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deviations From Optimal Alignment in TKA: Is There a Biomechanical Difference Between Femoral or Tibial Component Alignment?
    Innocenti B; Bellemans J; Catani F
    J Arthroplasty; 2016 Jan; 31(1):295-301. PubMed ID: 26321075
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The biomechanics of a validated finite element model of stress shielding in a novel hybrid total knee replacement.
    Bougherara H; Zdero R; Mahboob Z; Dubov A; Shah S; Schemitsch EH
    Proc Inst Mech Eng H; 2010 Oct; 224(10):1209-19. PubMed ID: 21138239
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Predicting the effect of tray malalignment on risk for bone damage and implant subsidence after total knee arthroplasty.
    Wong J; Steklov N; Patil S; Flores-Hernandez C; Kester M; Colwell CW; D'Lima DD
    J Orthop Res; 2011 Mar; 29(3):347-53. PubMed ID: 20882595
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.