These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 27747643)
1. Effect of implant design on primary stability using torque-time curves in artificial bone. Yamaguchi Y; Shiota M; Munakata M; Kasugai S; Ozeki M Int J Implant Dent; 2015 Dec; 1(1):21. PubMed ID: 27747643 [TBL] [Abstract][Full Text] [Related]
2. Development and application of a direct method to observe the implant/bone interface using simulated bone. Yamaguchi Y; Shiota M; FuJii M; Sekiya M; Ozeki M Springerplus; 2016; 5():494. PubMed ID: 27186458 [TBL] [Abstract][Full Text] [Related]
3. One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant. Friberg B; Jisander S; Widmark G; Lundgren A; Ivanoff CJ; Sennerby L; Thorén C Clin Implant Dent Relat Res; 2003; 5(2):71-7. PubMed ID: 14536040 [TBL] [Abstract][Full Text] [Related]
4. Macrogeometric Differentiation of Dental Implant Primary Stability: An In Vitro Study. Al-Tarawneh SK; Thalji G; Cooper LF Int J Oral Maxillofac Implants; 2022; 37(6):1110-1118. PubMed ID: 36450016 [TBL] [Abstract][Full Text] [Related]
5. Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants. Al-Nawas B; Wagner W; Grötz KA Int J Oral Maxillofac Implants; 2006; 21(5):726-32. PubMed ID: 17066633 [TBL] [Abstract][Full Text] [Related]
6. The effect of implant design and bone quality on insertion torque, resonance frequency analysis, and insertion energy during implant placement in low or low- to medium-density bone. Wang TM; Lee MS; Wang JS; Lin LD Int J Prosthodont; 2015; 28(1):40-7. PubMed ID: 25588172 [TBL] [Abstract][Full Text] [Related]
7. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. O'Sullivan D; Sennerby L; Meredith N Clin Implant Dent Relat Res; 2000; 2(2):85-92. PubMed ID: 11359268 [TBL] [Abstract][Full Text] [Related]
8. Effect of Osteotomy Preparation on Osseointegration of Immediately Loaded, Tapered Dental Implants. Stavropoulos A; Cochran D; Obrecht M; Pippenger BE; Dard M Adv Dent Res; 2016 Mar; 28(1):34-41. PubMed ID: 26927486 [TBL] [Abstract][Full Text] [Related]
9. A comparison of two methods of enhancing implant primary stability. O'Sullivan D; Sennerby L; Jagger D; Meredith N Clin Implant Dent Relat Res; 2004; 6(1):48-57. PubMed ID: 15595709 [TBL] [Abstract][Full Text] [Related]
10. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis. Falco A; Berardini M; Trisi P Int J Oral Maxillofac Implants; 2018; 33(4):824-830. PubMed ID: 30024998 [TBL] [Abstract][Full Text] [Related]
11. A Comparison of Tapered and Nontapered Implants in the Minipig. Cochran D; Stavropoulos A; Obrecht M; Pippenger B; Dard M Int J Oral Maxillofac Implants; 2016; 31(6):1341-1347. PubMed ID: 27861658 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of local cancellous bone amelioration by poly-L-DL-lactide copolymers to improve primary stability of dental implants: a biomechanical study in sheep. Stübinger S; Waser J; Hefti T; Drechsler A; Sidler M; Klein K; von Rechenberg B; Schlottig F Clin Oral Implants Res; 2015 May; 26(5):572-80. PubMed ID: 24989873 [TBL] [Abstract][Full Text] [Related]
13. Insertion Torque of Variable-Thread Tapered Implants in the Posterior Maxilla: A Clinical Study. Abi-Aad HL; Daher FI; Baba NZ; Cordioli G; Majzoub ZAK J Prosthodont; 2019 Feb; 28(2):e788-e794. PubMed ID: 30178903 [TBL] [Abstract][Full Text] [Related]
14. The effects of superficial roughness and design on the primary stability of dental implants. Dos Santos MV; Elias CN; Cavalcanti Lima JH Clin Implant Dent Relat Res; 2011 Sep; 13(3):215-23. PubMed ID: 19744197 [TBL] [Abstract][Full Text] [Related]
15. Tapered Implants in Dentistry: Revitalizing Concepts with Technology: A Review. Wilson TG; Miller RJ; Trushkowsky R; Dard M Adv Dent Res; 2016 Mar; 28(1):4-9. PubMed ID: 26927482 [TBL] [Abstract][Full Text] [Related]
16. The effect of various thread designs on the initial stability of taper implants. Park JH; Lim YJ; Kim MJ; Kwon HB J Adv Prosthodont; 2009 Mar; 1(1):19-25. PubMed ID: 21165250 [TBL] [Abstract][Full Text] [Related]
17. Comparison of primary stability of straight-walled and tapered implants using an insertion torque device. Menicucci G; Pachie E; Lorenzetti M; Migliaretti G; Carossa S Int J Prosthodont; 2012; 25(5):465-71. PubMed ID: 22930768 [TBL] [Abstract][Full Text] [Related]
18. Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs. Di Stefano DA; Arosio P; Perrotti V; Iezzi G; Scarano A; Piattelli A Dent J (Basel); 2019 Mar; 7(1):. PubMed ID: 30841588 [TBL] [Abstract][Full Text] [Related]
19. The effect of miniscrew taper morphology on insertion and removal torque in dogs. Cha JY; Takano-Yamamoto T; Hwang CJ Int J Oral Maxillofac Implants; 2010; 25(4):777-83. PubMed ID: 20657874 [TBL] [Abstract][Full Text] [Related]
20. Comparison of insertion torque, implant stability quotient and removal torque, in two different implant designs with and without osseodensification. - An ex vivo bench top study. Gandhi Y; Padhye N J Oral Biol Craniofac Res; 2023; 13(2):249-252. PubMed ID: 36818026 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]