220 related articles for article (PubMed ID: 27759423)
21. Fast T1 mapping of the brain at high field using Look-Locker and fast imaging.
Jiang K; Zhu Y; Jia S; Wu Y; Liu X; Chung YC
Magn Reson Imaging; 2017 Feb; 36():49-55. PubMed ID: 27989908
[TBL] [Abstract][Full Text] [Related]
22. Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart.
Messroghli DR; Radjenovic A; Kozerke S; Higgins DM; Sivananthan MU; Ridgway JP
Magn Reson Med; 2004 Jul; 52(1):141-6. PubMed ID: 15236377
[TBL] [Abstract][Full Text] [Related]
23. 3D SASHA myocardial T1 mapping with high accuracy and improved precision.
Nordio G; Bustin A; Henningsson M; Rashid I; Chiribiri A; Ismail T; Odille F; Prieto C; Botnar RM
MAGMA; 2019 Apr; 32(2):281-289. PubMed ID: 30191345
[TBL] [Abstract][Full Text] [Related]
24. Diffusion-sensitized ophthalmic magnetic resonance imaging free of geometric distortion at 3.0 and 7.0 T: a feasibility study in healthy subjects and patients with intraocular masses.
Paul K; Graessl A; Rieger J; Lysiak D; Huelnhagen T; Winter L; Heidemann R; Lindner T; Hadlich S; Zimpfer A; Pohlmann A; Endemann B; Krüger PC; Langner S; Stachs O; Niendorf T
Invest Radiol; 2015 May; 50(5):309-21. PubMed ID: 25612144
[TBL] [Abstract][Full Text] [Related]
25. Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition (CABIRIA).
Santini F; Kawel-Boehm N; Greiser A; Bremerich J; Bieri O
Magn Reson Med; 2015 Aug; 74(2):365-71. PubMed ID: 25113911
[TBL] [Abstract][Full Text] [Related]
26. Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T.
Ferreira da Silva T; Galan-Arriola C; Montesinos P; López-Martín GJ; Desco M; Fuster V; Ibáñez B; Sanchez-Gonzalez J
MAGMA; 2020 Dec; 33(6):865-876. PubMed ID: 32410103
[TBL] [Abstract][Full Text] [Related]
27. Free-breathing myocardial T
Wang X; Rosenzweig S; Roeloffs V; Blumenthal M; Scholand N; Tan Z; Holme HCM; Unterberg-Buchwald C; Hinkel R; Uecker M
Magn Reson Med; 2023 Apr; 89(4):1368-1384. PubMed ID: 36404631
[TBL] [Abstract][Full Text] [Related]
28. SAturation-recovery and Variable-flip-Angle-based three-dimensional free-breathing cardiovascular magnetic resonance T
Guo R; Si D; Chen Z; Dai E; Chen S; Herzka DA; Luo J; Ding H
NMR Biomed; 2022 Sep; 35(9):e4755. PubMed ID: 35485432
[TBL] [Abstract][Full Text] [Related]
29. Free-breathing 3D cardiac T
Han PK; Marin T; Djebra Y; Landes V; Zhuo Y; El Fakhri G; Ma C
Magn Reson Med; 2022 Apr; 87(4):1832-1845. PubMed ID: 34812547
[TBL] [Abstract][Full Text] [Related]
30. 3D myocardial T1 mapping at 3T using variable flip angle method: pilot study.
Clique H; Cheng HL; Marie PY; Felblinger J; Beaumont M
Magn Reson Med; 2014 Feb; 71(2):823-9. PubMed ID: 23440632
[TBL] [Abstract][Full Text] [Related]
31. Single-shot inversion recovery TrueFISP for assessment of myocardial infarction.
Huber A; Schoenberg SO; Spannagl B; Rieber J; Erhard I; Klauss V; Reiser MF
AJR Am J Roentgenol; 2006 Mar; 186(3):627-33. PubMed ID: 16498088
[TBL] [Abstract][Full Text] [Related]
32. Dual flip-angle IR-FLASH with spin history mapping for B1+ corrected T1 mapping: Application to T1 cardiovascular magnetic resonance multitasking.
Serry FM; Ma S; Mao X; Han F; Xie Y; Han H; Li D; Christodoulou AG
Magn Reson Med; 2021 Dec; 86(6):3182-3191. PubMed ID: 34309072
[TBL] [Abstract][Full Text] [Related]
33. Arrhythmia insensitive rapid cardiac T1 mapping pulse sequence.
Fitts M; Breton E; Kholmovski EG; Dosdall DJ; Vijayakumar S; Hong KP; Ranjan R; Marrouche NF; Axel L; Kim D
Magn Reson Med; 2013 Nov; 70(5):1274-82. PubMed ID: 23280998
[TBL] [Abstract][Full Text] [Related]
34. Free-breathing quantitative dynamic contrast-enhanced magnetic resonance imaging in a rat liver tumor model using dynamic radial T(1) mapping.
Braren R; Curcic J; Remmele S; Altomonte J; Ebert O; Rummeny EJ; Steingoetter A
Invest Radiol; 2011 Oct; 46(10):624-31. PubMed ID: 21577121
[TBL] [Abstract][Full Text] [Related]
35. Repeatability of Open-MOLLI: An open-source inversion recovery myocardial T1 mapping sequence for fast prototyping.
Gaspar AS; Silva NA; Ferreira AM; Nunes RG
Magn Reson Med; 2024 Aug; 92(2):741-750. PubMed ID: 38523462
[TBL] [Abstract][Full Text] [Related]
36. Real-time MRI at a resolution of 20 ms.
Uecker M; Zhang S; Voit D; Karaus A; Merboldt KD; Frahm J
NMR Biomed; 2010 Oct; 23(8):986-94. PubMed ID: 20799371
[TBL] [Abstract][Full Text] [Related]
37. Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart.
Messroghli DR; Greiser A; Fröhlich M; Dietz R; Schulz-Menger J
J Magn Reson Imaging; 2007 Oct; 26(4):1081-6. PubMed ID: 17896383
[TBL] [Abstract][Full Text] [Related]
38. Systolic ShMOLLI myocardial T1-mapping for improved robustness to partial-volume effects and applications in tachyarrhythmias.
Ferreira VM; Wijesurendra RS; Liu A; Greiser A; Casadei B; Robson MD; Neubauer S; Piechnik SK
J Cardiovasc Magn Reson; 2015 Aug; 17(1):77. PubMed ID: 26315682
[TBL] [Abstract][Full Text] [Related]
39. Single breath-hold MR T1 mapping in the heart: Hybrid MOLLI combining saturation and inversion recovery.
Yu CY; Huang TY; Chung HW
Magn Reson Imaging; 2023 Feb; 96():85-92. PubMed ID: 36470451
[TBL] [Abstract][Full Text] [Related]
40. SUPER: A blockwise curve-fitting method for accelerating MR parametric mapping with fast reconstruction.
Hu C; Peters DC
Magn Reson Med; 2019 Jun; 81(6):3515-3529. PubMed ID: 30656730
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]