  • 1. Comparison of short-axis out-of-plane versus long-axis in-plane ultrasound-guided radial arterial cannulation in adult patients: a randomized controlled trial.
    Sethi S; Maitra S; Saini V; Samra T; Malhotra SK
    J Anesth; 2017 Feb; 31(1):89-94. PubMed ID: 27761661
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?
    Berk D; Gurkan Y; Kus A; Ulugol H; Solak M; Toker K
    J Clin Monit Comput; 2013 Jun; 27(3):319-24. PubMed ID: 23417581
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modified short-axis out-of-plane ultrasound versus conventional long-axis in-plane ultrasound to guide radial artery cannulation: a randomized controlled trial.
    Quan Z; Tian M; Chi P; Cao Y; Li X; Peng K
    Anesth Analg; 2014 Jul; 119(1):163-169. PubMed ID: 24806143
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Short-axis/out-of-plane or long-axis/in-plane ultrasound-guided arterial cannulation in children: A randomised controlled trial.
    Song IK; Choi JY; Lee JH; Kim EH; Kim HJ; Kim HS; Kim JT
    Eur J Anaesthesiol; 2016 Jul; 33(7):522-7. PubMed ID: 26986774
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-axis in-plane combined with short-axis out-of-plane technique in ultrasound-guided arterial catheterization in infants: A randomized controlled trial.
    Wang Z; Guo H; Shi S; Xu Y; Ye M; Bai L; Tan Y; Li Y; Liu L
    J Clin Anesth; 2023 May; 85():111038. PubMed ID: 36603327
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Modified long-axis in-plane ultrasound technique versus conventional palpation technique for radial arterial cannulation: A prospective randomized controlled trial.
    Wang J; Lai Z; Weng X; Lin Y; Wu G; Su J; Huang Q; Zeng J; Liu J; Zhao Z; Yan T; Zhang L; Zhou L
    Medicine (Baltimore); 2020 Jan; 99(2):e18747. PubMed ID: 31914094
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Forty-five degree wrist angulation is optimal for ultrasound guided long axis radial artery cannulation in patients over 60 years old: a randomized study.
    Kucuk A; Yuce HH; Yalcin F; Boyacı FN; Yıldız S; Yalcin S
    J Clin Monit Comput; 2014 Dec; 28(6):567-72. PubMed ID: 24414382
    [TBL] [Abstract][Full Text] [Related]  

  • 8. "Modified Dynamic Needle Tip Positioning" Short-Axis, Out-of-Plane, Ultrasound-Guided Radial Artery Cannulation in Neonates: A Randomized Controlled Trial.
    Liu L; Tan Y; Li S; Tian J
    Anesth Analg; 2019 Jul; 129(1):178-183. PubMed ID: 29787409
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dynamic needle tip positioning versus the angle-distance technique for ultrasound-guided radial artery cannulation in adults: a randomized controlled trial.
    Bai B; Tian Y; Zhang Y; Yu C; Huang Y
    BMC Anesthesiol; 2020 Sep; 20(1):231. PubMed ID: 32928119
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasound-guided radial artery cannulation using dynamic needle tip positioning versus conventional long-axis in-plane techniques in cardiac surgery patients: a randomized, controlled trial.
    Nam K; Jeon Y; Yoon S; Kwon SM; Kang P; Cho YJ; Kim TK
    Minerva Anestesiol; 2020 Jan; 86(1):30-37. PubMed ID: 31213045
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison between the long-axis in-plane and short-axis out-of-plane approaches for ultrasound-guided arterial cannulation: a meta-analysis and systematic review.
    Cao L; Tan YT; Wei T; Li H
    BMC Anesthesiol; 2023 Apr; 23(1):120. PubMed ID: 37055775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.
    Bhattacharjee S; Maitra S; Baidya DK
    J Clin Anesth; 2018 Jun; 47():54-59. PubMed ID: 29574288
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasound Versus Traditional Palpation to Guide Radial Artery Cannulation in Critically Ill Children: A Randomized Trial.
    Anantasit N; Cheeptinnakorntaworn P; Khositseth A; Lertbunrian R; Chantra M
    J Ultrasound Med; 2017 Dec; 36(12):2495-2501. PubMed ID: 28688136
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acoustic Shadowing Facilitates Ultrasound-guided Radial Artery Cannulation in Young Children.
    Quan Z; Zhang L; Zhou C; Chi P; He H; Li Y
    Anesthesiology; 2019 Nov; 131(5):1018-1024. PubMed ID: 31634245
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of long axis in-plane vs short axis out-of-plane techniques during ultrasound-guided vascular access.
    Gao YB; Yan JH; Ma JM; Liu XN; Dong JY; Sun F; Tang LW; Li J
    Am J Emerg Med; 2016 May; 34(5):778-83. PubMed ID: 26830218
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrasound-Guided Out-of-Plane Versus In-Plane Radial Artery Cannulation in Adult Cardiac Surgical Patients.
    Arora NR; Maddali MM; Al-Sheheimi RAR; Al-Mughairi H; Panchatcharam SM
    J Cardiothorac Vasc Anesth; 2021 Jan; 35(1):84-88. PubMed ID: 32891521
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Distal tourniquet-facilitated radial arterial cannulation in adults--a double-blinded, prospective, randomized and controlled study.
    Zhou Q; Yao J; Chen Y; Lu J; Zhang X; Jiang W
    J Vasc Access; 2015; 16(2):158-62. PubMed ID: 25362980
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modified long-axis in-plane ultrasound-guided radial artery cannulation in adult patients: A randomized controlled trial.
    Wang J; Weng X; Huang Q; Lai Z; Zhao Z; Lan J; Wu G; Lin L; Su J; Liu J; Zhang L
    Anaesth Crit Care Pain Med; 2022 Feb; 41(1):100989. PubMed ID: 34864274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultrasound-Guided Dynamic Needle Tip Positioning Technique Versus Palpation Technique for Radial Arterial Cannulation in Adult Surgical Patients: A Randomized Controlled Trial.
    Kiberenge RK; Ueda K; Rosauer B
    Anesth Analg; 2018 Jan; 126(1):120-126. PubMed ID: 29135593
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrasound-guided short-axis out-of-plane vs. long-axis in-plane technique for radial artery catheterization: an updated meta-analysis of randomized controlled trials.
    Wang HH; Wang JJ; Chen WT
    Eur Rev Med Pharmacol Sci; 2022 Mar; 26(6):1914-1922. PubMed ID: 35363340
    [TBL] [Abstract][Full Text] [Related]  