BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1114 related articles for article (PubMed ID: 27767022)

  • 21. Study on improved tribological properties by alloying copper to CP-Ti and Ti-6Al-4V alloy.
    Wang S; Ma Z; Liao Z; Song J; Yang K; Liu W
    Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():123-32. PubMed ID: 26354247
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Mechanical properties of cast Ti-6Al-4V-XCu alloys.
    Aoki T; Okafor IC; Watanabe I; Hattori M; Oda Y; Okabe T
    J Oral Rehabil; 2004 Nov; 31(11):1109-14. PubMed ID: 15525390
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of ultrasonic micro-arc oxidation on the antibacterial properties and cell biocompatibility of Ti-Cu alloy for biomedical application.
    Hu J; Li H; Wang X; Yang L; Chen M; Wang R; Qin G; Chen DF; Zhang E
    Mater Sci Eng C Mater Biol Appl; 2020 Oct; 115():110921. PubMed ID: 32600677
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ti-30Nb-3Ag alloy with improved corrosion resistance and antibacterial properties for orthopedic and dental applications produced by mechanical alloying.
    Hussein MA; Kumar AM; Azeem MA; Sorour AA; Saravanan S
    J Mech Behav Biomed Mater; 2023 Jun; 142():105851. PubMed ID: 37068434
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vitro study on an antibacterial Ti-5Cu alloy for medical application.
    Ma Z; Li M; Liu R; Ren L; Zhang Y; Pan H; Zhao Y; Yang K
    J Mater Sci Mater Med; 2016 May; 27(5):91. PubMed ID: 26975748
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Microstructures, mechanical properties, and degradation behaviors of heat-treated Mg-Sr alloys as potential biodegradable implant materials.
    Wang Y; Tie D; Guan R; Wang N; Shang Y; Cui T; Li J
    J Mech Behav Biomed Mater; 2018 Jan; 77():47-57. PubMed ID: 28888933
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Microstructure, mechanical strength, chemical resistance, and antibacterial behavior of Ti-5Cu-
    Pandey AK; Gautam RK; Behera CK
    Biomed Mater; 2022 Jun; 17(4):. PubMed ID: 35679847
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Design and preparation of Ti-xFe antibacterial titanium alloys based on micro-area potential difference.
    Xie Y; Cui S; Hu J; Yu H; Xuan A; Wei Y; Lian Y; Wu J; Du W; Zhang E
    Biometals; 2024 Apr; 37(2):337-355. PubMed ID: 37904075
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Microstructure and mechanical properties of Ti-Zr-Cr biomedical alloys.
    Wang P; Feng Y; Liu F; Wu L; Guan S
    Mater Sci Eng C Mater Biol Appl; 2015 Jun; 51():148-52. PubMed ID: 25842119
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of Ti
    Wu JH; Chen KK; Chao CY; Chang YH; Du JK
    Mater Sci Eng C Mater Biol Appl; 2020 Mar; 108():110433. PubMed ID: 31923945
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A new antibacterial Co-Cr-Mo-Cu alloy: Preparation, biocorrosion, mechanical and antibacterial property.
    Zhang E; Liu C
    Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():134-43. PubMed ID: 27612698
    [No Abstract]   [Full Text] [Related]  

  • 32. Effect of Cu Content on the Precipitation Behaviors, Mechanical and Corrosion Properties of As-Cast Ti-Cu Alloys.
    Wang Z; Fu B; Wang Y; Dong T; Li J; Li G; Zhao X; Liu J; Zhang G
    Materials (Basel); 2022 Feb; 15(5):. PubMed ID: 35268932
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Microstructure, Wettability, Corrosion Resistance and Antibacterial Property of Cu-MTa
    Ding Z; Wang Y; Zhou Q; Ding Z; Liu J; He Q; Zhang H
    Biomolecules; 2019 Dec; 10(1):. PubMed ID: 31906220
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Mechanical properties and microstructures of dental cast Ti-Ag and Ti-Cu alloys.
    Takahashi M; Kikuchi M; Takada Y; Okuno O
    Dent Mater J; 2002 Sep; 21(3):270-80. PubMed ID: 12474954
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Microstructure, corrosion and tribological and antibacterial properties of Ti-Cu coated stainless steel.
    Jin X; Gao L; Liu E; Yu F; Shu X; Wang H
    J Mech Behav Biomed Mater; 2015 Oct; 50():23-32. PubMed ID: 26093948
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Potential biodegradable Zn-Cu binary alloys developed for cardiovascular implant applications.
    Tang Z; Niu J; Huang H; Zhang H; Pei J; Ou J; Yuan G
    J Mech Behav Biomed Mater; 2017 Aug; 72():182-191. PubMed ID: 28499166
    [TBL] [Abstract][Full Text] [Related]  

  • 37. What controls the antibacterial activity of Ti-Ag alloy, Ag ion or Ti
    Shi A; Zhu C; Fu S; Wang R; Qin G; Chen D; Zhang E
    Mater Sci Eng C Mater Biol Appl; 2020 Apr; 109():110548. PubMed ID: 32228943
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biocorrosion properties of antibacterial Ti-10Cu sintered alloy in several simulated biological solutions.
    Liu C; Zhang E
    J Mater Sci Mater Med; 2015 Mar; 26(3):142. PubMed ID: 25737127
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Cu-Ti, Co-Ti and Ni-Ti systems: corrosion and microhardness.
    Chern Lin JH; Moser JB; Taira M; Greener EH
    J Oral Rehabil; 1990 Jul; 17(4):383-93. PubMed ID: 2213334
    [TBL] [Abstract][Full Text] [Related]  

  • 40. In vitro and in vivo studies of anti-bacterial copper-bearing titanium alloy for dental application.
    Liu R; Tang Y; Zeng L; Zhao Y; Ma Z; Sun Z; Xiang L; Ren L; Yang K
    Dent Mater; 2018 Aug; 34(8):1112-1126. PubMed ID: 29709241
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 56.