These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 27767983)

  • 1. Potentialities of laser trapping and manipulation of blood cells in hemorheologic research.
    Priezzhev A; Lee K
    Clin Hemorheol Microcirc; 2016; 64(4):587-592. PubMed ID: 27767983
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical force characterization in manipulating live cells with optical tweezers.
    Wu Y; Sun D; Huang W
    J Biomech; 2011 Feb; 44(4):741-6. PubMed ID: 21087769
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Laser trapping of colloidal metal nanoparticles.
    Lehmuskero A; Johansson P; Rubinsztein-Dunlop H; Tong L; Käll M
    ACS Nano; 2015; 9(4):3453-69. PubMed ID: 25808609
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Physics of optical tweezers.
    Nieminen TA; Knöner G; Heckenberg NR; Rubinsztein-Dunlop H
    Methods Cell Biol; 2007; 82():207-36. PubMed ID: 17586258
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multiplying optical tweezers force using a micro-lever.
    Lin CL; Lee YH; Lin CT; Liu YJ; Hwang JL; Chung TT; Baldeck PL
    Opt Express; 2011 Oct; 19(21):20604-9. PubMed ID: 21997068
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optical trapping and manipulation for single-particle spectroscopy and microscopy.
    Chen Z; Cai Z; Liu W; Yan Z
    J Chem Phys; 2022 Aug; 157(5):050901. PubMed ID: 35933217
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Introduction to Optical Tweezers.
    Koch MD; Shaevitz JW
    Methods Mol Biol; 2017; 1486():3-24. PubMed ID: 27844423
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization at the individual cell level and in whole blood samples of shear stress preventing red blood cells aggregation.
    Lee K; Kinnunen M; Danilina AV; Ustinov VD; Shin S; Meglinski I; Priezzhev AV
    J Biomech; 2016 May; 49(7):1021-1026. PubMed ID: 26916508
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical analysis for transverse microbead trapping using 30 MHz focused ultrasound in ray acoustics regime.
    Lee J
    Ultrasonics; 2014 Jan; 54(1):11-9. PubMed ID: 23809757
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dynamic deformation of red blood cell in dual-trap optical tweezers.
    Rancourt-Grenier S; Wei MT; Bai JJ; Chiou A; Bareil PP; Duval PL; Sheng Y
    Opt Express; 2010 May; 18(10):10462-72. PubMed ID: 20588900
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optical tweezers based force measurement system for quantitating binding interactions: system design and application for the study of bacterial adhesion.
    Fällman E; Schedin S; Jass J; Andersson M; Uhlin BE; Axner O
    Biosens Bioelectron; 2004 Jun; 19(11):1429-37. PubMed ID: 15093214
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Direct 2D measurement of time-averaged forces and pressure amplitudes in acoustophoretic devices using optical trapping.
    Lakämper S; Lamprecht A; Schaap IA; Dual J
    Lab Chip; 2015 Jan; 15(1):290-300. PubMed ID: 25370872
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Numerical study of the properties of optical vortex array laser tweezers.
    Kuo CF; Chu SC
    Opt Express; 2013 Nov; 21(22):26418-31. PubMed ID: 24216863
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The combination of optical tweezers and microwell array for cells physical manipulation and localization in microfluidic device.
    Luo C; Li H; Xiong C; Peng X; Kou Q; Chen Y; Ji H; Ouyang Q
    Biomed Microdevices; 2007 Aug; 9(4):573-8. PubMed ID: 17484053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Amphibious Hybrid Laser Tweezers for Fluid and Solid Domains.
    Zhu R; Shen T; Gu Z; Shi Z; Dou L; Liu Y; Zhuang S; Gu F
    ACS Nano; 2024 Aug; 18(34):23232-23242. PubMed ID: 39145514
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Higher order microfibre modes for dielectric particle trapping and propulsion.
    Maimaiti A; Truong VG; Sergides M; Gusachenko I; Nic Chormaic S
    Sci Rep; 2015 Mar; 5():9077. PubMed ID: 25766925
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Combined acoustic and optical trapping.
    Thalhammer G; Steiger R; Meinschad M; Hill M; Bernet S; Ritsch-Marte M
    Biomed Opt Express; 2011 Oct; 2(10):2859-70. PubMed ID: 22025990
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hydrodynamic tweezers: 1. Noncontact trapping of single cells using steady streaming microeddies.
    Lutz BR; Chen J; Schwartz DT
    Anal Chem; 2006 Aug; 78(15):5429-35. PubMed ID: 16878879
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Silicon-on-insulator multimode-interference waveguide-based arrayed optical tweezers (SMART) for two-dimensional microparticle trapping and manipulation.
    Lei T; Poon AW
    Opt Express; 2013 Jan; 21(2):1520-30. PubMed ID: 23389134
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contact Electrification of Individual Dielectric Microparticles Measured by Optical Tweezers in Air.
    Park H; LeBrun TW
    ACS Appl Mater Interfaces; 2016 Dec; 8(50):34904-34913. PubMed ID: 27936542
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.