BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

948 related articles for article (PubMed ID: 27776939)

  • 1. Development of Collaterals to the Spinal Cord after Endovascular Stent Graft Repair of Thoracic Aneurysms.
    Fukui S; Tanaka H; Kobayashi K; Kajiyama T; Mitsuno M; Yamamura M; Ryomoto M; Miyamoto Y
    Eur J Vasc Endovasc Surg; 2016 Dec; 52(6):801-807. PubMed ID: 27776939
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypogastric and subclavian artery patency affects onset and recovery of spinal cord ischemia associated with aortic endografting.
    Eagleton MJ; Shah S; Petkosevek D; Mastracci TM; Greenberg RK
    J Vasc Surg; 2014 Jan; 59(1):89-94. PubMed ID: 24188715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of visible spinal arteries on computed tomography angiography before and after branched stent graft repair for thoracoabdominal aortic aneurysm.
    Gallis K; Kasprzak PM; Cucuruz B; Kopp R
    J Vasc Surg; 2017 Jun; 65(6):1577-1583. PubMed ID: 28216346
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Extensive endovascular repair of thoracic aorta: observational analysis of the results and effects on spinal cord perfusion.
    Mastroroberto P; Ciranni S; Indolfi C
    J Cardiovasc Surg (Torino); 2013 Aug; 54(4):523-30. PubMed ID: 23369947
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Decision to Interrupt Second-Stage Side-Branch Completion in Thoracoabdominal Branched Aortic Stent Grafting to Prevent Spinal Cord Ischemia.
    Touma J; Benamara B; Kobeiter H; Desgranges P
    Ann Vasc Surg; 2017 Jul; 42():303.e1-303.e4. PubMed ID: 28389286
    [TBL] [Abstract][Full Text] [Related]  

  • 6. First-in-man endovascular preconditioning of the paraspinal collateral network by segmental artery coil embolization to prevent ischemic spinal cord injury.
    Etz CD; Debus ES; Mohr FW; Kölbel T
    J Thorac Cardiovasc Surg; 2015 Apr; 149(4):1074-9. PubMed ID: 25906717
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Neuromonitoring, Cerebrospinal Fluid Drainage, and Selective Use of Iliofemoral Conduits to Minimize Risk of Spinal Cord Injury During Complex Endovascular Aortic Repair.
    Banga PV; Oderich GS; Reis de Souza L; Hofer J; Cazares Gonzalez ML; Pulido JN; Cha S; Gloviczki P
    J Endovasc Ther; 2016 Feb; 23(1):139-49. PubMed ID: 26637837
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcomes of planned celiac artery coverage during TEVAR.
    Mehta M; Darling RC; Taggert JB; Roddy SP; Sternbach Y; Ozsvath KJ; Kreienberg PB; Paty PS
    J Vasc Surg; 2010 Nov; 52(5):1153-8. PubMed ID: 20709480
    [TBL] [Abstract][Full Text] [Related]  

  • 9. New Technique for Preconditioning of the Spinal Cord Before Endovascular Repair of Descending Thoracic and Thoracoabdominal Aortic Aneurysms.
    Sonesson B; Dias NV; Resch TA
    J Endovasc Ther; 2019 Oct; 26(5):691-696. PubMed ID: 31379279
    [No Abstract]   [Full Text] [Related]  

  • 10. Safety and durability of infrarenal aorta as distal landing zone in fenestrated or branched endograft repair for thoracoabdominal aneurysm.
    Law Y; Kölbel T; Rohlffs F; Behrendt C; Heidemann F; Debus ES; Tsilimparis N
    J Vasc Surg; 2019 Feb; 69(2):334-340. PubMed ID: 29945837
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Modified Proximal Stent-Graft for Spinal Cord Preconditioning During Staged Endovascular Repair of Thoracoabdominal Aortic Aneurysms.
    Rinaldi E; Carta N; Melissano G; Chiesa R; Bertoglio L
    J Endovasc Ther; 2020 Oct; 27(5):764-768. PubMed ID: 32452238
    [No Abstract]   [Full Text] [Related]  

  • 12. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.
    Chang CK; Chuter TA; Reilly LM; Ota MK; Furtado A; Bucci M; Wintermark M; Hiramoto JS
    J Endovasc Ther; 2008 Jun; 15(3):356-62. PubMed ID: 18540712
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of hybrid thoracoabdominal aortic repair on visceral and spinal cord perfusion: The new and improved SPIDER-graft.
    Wipper S; Kölbel T; Sandhu HK; Manzoni D; Duprée A; Estrera AL; Safi H; Miller CC; Tsilimparis N; Debus ES
    J Thorac Cardiovasc Surg; 2019 Sep; 158(3):692-701. PubMed ID: 30745044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Open surgical repair of descending thoracic aortic aneurysms in the endovascular era: a 9-year single-center study.
    Kieffer E; Chiche L; Cluzel P; Godet G; Koskas F; Bahnini A
    Ann Vasc Surg; 2009; 23(1):60-6. PubMed ID: 18809288
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Homemade fenestrated stent-graft for thoracic endovascular aortic repair of zone 2 aortic lesions.
    Canaud L; Morishita K; Gandet T; Sfeir J; Bommart S; Alric P; Mandelli M
    J Thorac Cardiovasc Surg; 2018 Feb; 155(2):488-493. PubMed ID: 28867380
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of sacrificed healthy aorta during thoracoabdominal aortic aneurysm repair using off-the-shelf endovascular branched devices and open surgery.
    Bertoglio L; Cambiaghi T; Ferrer C; Baccellieri D; Verzini F; Melissano G; Chiesa R; Tshomba Y
    J Vasc Surg; 2018 Mar; 67(3):695-702. PubMed ID: 29100806
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Feasibility Study of Off-the-Shelf Scalloped Stent-Grafts in Acute Type B Aortic Dissection.
    van der Weijde E; Bakker OJ; Kamman AV; van Herwaarden JA; Trimarchi S; Vos JA; Heijmen RH
    J Endovasc Ther; 2017 Dec; 24(6):819-824. PubMed ID: 28814171
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Management of blunt traumatic thoracic aorta injuries with endovascular stent-grafts in a tertiary hospital in an urban Asian city.
    Leong Tan GW; Pek CH; Wong D; Punamiya S; Chiu MT; Appasamy V; Chia KH; Lee CW
    Ann Vasc Surg; 2011 Jul; 25(5):605-11. PubMed ID: 21435831
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The "Open Branch" Technique: A New Way to Prevent Paraplegia After Total Endovascular Repair of Thoracoabdominal Aneurysm.
    Mangialardi N; Lachat M; Esposito A; Puippe G; Orrico M; Alberti V; Fazzini S; Ronchey S
    Catheter Cardiovasc Interv; 2016 Mar; 87(4):773-80. PubMed ID: 26708446
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The assessment of collateral communication after hybrid repair for Crawford extent II thoraco-abdominal aortic aneurysms.
    Shijo T; Kuratani T; Shirakawa Y; Torikai K; Shimamura K; Sakamoto T; Watanabe Y; Maeda N; Tomiyama N; Sawa Y
    Eur J Cardiothorac Surg; 2015 Dec; 48(6):960-7; discussion 967. PubMed ID: 25691067
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 48.