252 related articles for article (PubMed ID: 27777640)
1. Neuromimetic Event-Based Detection for Closed-Loop Tactile Feedback Control of Upper Limb Prostheses.
Osborn L; Kaliki R; Soares A; Thakor N
IEEE Trans Haptics; 2016; 9(2):196-206. PubMed ID: 27777640
[TBL] [Abstract][Full Text] [Related]
2. Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users.
Witteveen HJ; Rietman HS; Veltink PH
Prosthet Orthot Int; 2015 Jun; 39(3):204-12. PubMed ID: 24567348
[TBL] [Abstract][Full Text] [Related]
3. Myocontrol is closed-loop control: incidental feedback is sufficient for scaling the prosthesis force in routine grasping.
Markovic M; Schweisfurth MA; Engels LF; Farina D; Dosen S
J Neuroeng Rehabil; 2018 Sep; 15(1):81. PubMed ID: 30176929
[TBL] [Abstract][Full Text] [Related]
4. Effects of Different Tactile Feedback on Myoelectric Closed-Loop Control for Grasping Based on Electrotactile Stimulation.
Xu H; Zhang D; Huegel JC; Xu W; Zhu X
IEEE Trans Neural Syst Rehabil Eng; 2016 Aug; 24(8):827-36. PubMed ID: 26372430
[TBL] [Abstract][Full Text] [Related]
5. Multichannel Electrotactile Feedback With Spatial and Mixed Coding for Closed-Loop Control of Grasping Force in Hand Prostheses.
Dosen S; Markovic M; Strbac M; Belic M; Kojic V; Bijelic G; Keller T; Farina D
IEEE Trans Neural Syst Rehabil Eng; 2017 Mar; 25(3):183-195. PubMed ID: 27071179
[TBL] [Abstract][Full Text] [Related]
6. Non-Invasive, Temporally Discrete Feedback of Object Contact and Release Improves Grasp Control of Closed-Loop Myoelectric Transradial Prostheses.
Clemente F; D'Alonzo M; Controzzi M; Edin BB; Cipriani C
IEEE Trans Neural Syst Rehabil Eng; 2016 Dec; 24(12):1314-1322. PubMed ID: 26584497
[TBL] [Abstract][Full Text] [Related]
7. Tactile feedback is an effective instrument for the training of grasping with a prosthesis at low- and medium-force levels.
De Nunzio AM; Dosen S; Lemling S; Markovic M; Schweisfurth MA; Ge N; Graimann B; Falla D; Farina D
Exp Brain Res; 2017 Aug; 235(8):2547-2559. PubMed ID: 28550423
[TBL] [Abstract][Full Text] [Related]
8. Generating tactile afferent stimulation patterns for slip and touch feedback in neural prosthetics.
Rager DM; Alvares D; Birznieks I; Redmond SJ; Morley JW; Lovell NH; Vickery RM
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():5922-5. PubMed ID: 24111087
[TBL] [Abstract][Full Text] [Related]
9. Electrotactile EMG feedback improves the control of prosthesis grasping force.
Schweisfurth MA; Markovic M; Dosen S; Teich F; Graimann B; Farina D
J Neural Eng; 2016 Oct; 13(5):056010. PubMed ID: 27547992
[TBL] [Abstract][Full Text] [Related]
10. The role of feed-forward and feedback processes for closed-loop prosthesis control.
Saunders I; Vijayakumar S
J Neuroeng Rehabil; 2011 Oct; 8():60. PubMed ID: 22032545
[TBL] [Abstract][Full Text] [Related]
11. Electrotactile Feedback with Spatial and Mixed Coding for Object Identification and Closed-loop Control of Grasping Force in Myoelectric Prostheses.
Chai G; Briand J; Su S; Sheng X; Zhu X
Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():1805-1808. PubMed ID: 31946247
[TBL] [Abstract][Full Text] [Related]
12. Tactile Feedback in Upper Limb Prosthetics: A Pilot Study on Trans-Radial Amputees Comparing Different Haptic Modalities.
Barontini F; Obermeier A; Catalano MG; Fani S; Grioli G; Bianchi M; Bicchi A; Jakubowitz E
IEEE Trans Haptics; 2023; 16(4):760-769. PubMed ID: 37801383
[TBL] [Abstract][Full Text] [Related]
13. Closed-loop control of grasping with a myoelectric hand prosthesis: which are the relevant feedback variables for force control?
Ninu A; Dosen S; Muceli S; Rattay F; Dietl H; Farina D
IEEE Trans Neural Syst Rehabil Eng; 2014 Sep; 22(5):1041-52. PubMed ID: 24801625
[TBL] [Abstract][Full Text] [Related]
14. Tactile Feedback in Upper Limb Prosthetic Devices Using Flexible Textile Force Sensors.
Osborn L; Lee WW; Kaliki R; Thakor N
Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron; 2014 Aug; 2014():114-119. PubMed ID: 33936859
[TBL] [Abstract][Full Text] [Related]
15. Electrotactile Feedback Improves Grip Force Control and Enables Object Stiffness Recognition While Using a Myoelectric Hand.
Chai G; Wang H; Li G; Sheng X; Zhu X
IEEE Trans Neural Syst Rehabil Eng; 2022; 30():1310-1320. PubMed ID: 35533165
[TBL] [Abstract][Full Text] [Related]
16. Non-Invasive Stable Sensory Feedback for Closed-Loop Control of Hand Prosthesis.
Zhang J; Chou CH; Wu X; Pei W; Lan N
Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():2344-2347. PubMed ID: 36086109
[TBL] [Abstract][Full Text] [Related]
17. EMG Biofeedback for online predictive control of grasping force in a myoelectric prosthesis.
Dosen S; Markovic M; Somer K; Graimann B; Farina D
J Neuroeng Rehabil; 2015 Jun; 12():55. PubMed ID: 26088323
[TBL] [Abstract][Full Text] [Related]
18. Intraneural sensory feedback restores grip force control and motor coordination while using a prosthetic hand.
Clemente F; Valle G; Controzzi M; Strauss I; Iberite F; Stieglitz T; Granata G; Rossini PM; Petrini F; Micera S; Cipriani C
J Neural Eng; 2019 Apr; 16(2):026034. PubMed ID: 30736030
[TBL] [Abstract][Full Text] [Related]
19. Neuromorphic vision and tactile fusion for upper limb prosthesis control.
Hays M; Osborn L; Ghosh R; Iskarous M; Hunt C; Thakor NV
Int IEEE EMBS Conf Neural Eng; 2019 Mar; 2019():981-984. PubMed ID: 33875927
[TBL] [Abstract][Full Text] [Related]
20. A Novel Sensory Feedback Approach to Facilitate Both Predictive and Corrective Control of Grasping Force in Myoelectric Prostheses.
Gasparic F; Jorgovanovic N; Hofer C; Russold MF; Koppe M; Stanisic D; Dosen S
IEEE Trans Neural Syst Rehabil Eng; 2023; 31():4492-4503. PubMed ID: 37930904
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]