BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

308 related articles for article (PubMed ID: 27788952)

  • 1. Comparison of Computed Tomography- and Magnetic Resonance Imaging-based Clinical Target Volume Contours at Brachytherapy for Cervical Cancer.
    Swanick CW; Castle KO; Vedam S; Munsell MF; Turner LM; Rauch GM; Jhingran A; Eifel PJ; Klopp AH
    Int J Radiat Oncol Biol Phys; 2016 Nov; 96(4):793-800. PubMed ID: 27788952
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of computed tomography with magnetic resonance imaging for imaging-based clinical target volume contours in cervical cancer brachytherapy.
    Zolciak-Siwinska A; Kowalczyk A; Sikorska K; Bijok M; Michalski W; Gruszczynska E
    Brachytherapy; 2018; 17(4):667-672. PubMed ID: 29764769
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Prospective Comparison of Computed Tomography with Transrectal Ultrasonography Assistance and Magnetic Resonance Imaging-Based Target-Volume Definition During Image Guided Adaptive Brachytherapy for Cervical Cancers.
    Mahantshetty U; Naga Ch P; Khadanga CR; Gudi S; Chopra S; Gurram L; Jamema S; Ghadi Y; Shrivastava S
    Int J Radiat Oncol Biol Phys; 2018 Dec; 102(5):1448-1456. PubMed ID: 30146092
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computed tomography versus magnetic resonance imaging-based contouring in cervical cancer brachytherapy: results of a prospective trial and preliminary guidelines for standardized contours.
    Viswanathan AN; Dimopoulos J; Kirisits C; Berger D; Pötter R
    Int J Radiat Oncol Biol Phys; 2007 Jun; 68(2):491-8. PubMed ID: 17331668
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of computed tomography and magnetic resonance imaging in cervical cancer brachytherapy target and normal tissue contouring.
    Eskander RN; Scanderbeg D; Saenz CC; Brown M; Yashar C
    Int J Gynecol Cancer; 2010 Jan; 20(1):47-53. PubMed ID: 20130502
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-risk clinical target volume delineation in CT-guided cervical cancer brachytherapy: impact of information from FIGO stage with or without systematic inclusion of 3D documentation of clinical gynecological examination.
    Hegazy N; Pötter R; Kirisits C; Berger D; Federico M; Sturdza A; Nesvacil N
    Acta Oncol; 2013 Oct; 52(7):1345-52. PubMed ID: 23905674
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Value of Magnetic Resonance Imaging Without or With Applicator in Place for Target Definition in Cervix Cancer Brachytherapy.
    Pötter R; Federico M; Sturdza A; Fotina I; Hegazy N; Schmid M; Kirisits C; Nesvacil N
    Int J Radiat Oncol Biol Phys; 2016 Mar; 94(3):588-97. PubMed ID: 26867887
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel use of ViewRay MRI guidance for high-dose-rate brachytherapy in the treatment of cervical cancer.
    Ko HC; Huang JY; Miller JR; Das RK; Wallace CR; De Costa AA; Francis DM; Straub MR; Anderson BM; Bradley KA
    Brachytherapy; 2018; 17(4):680-688. PubMed ID: 29773331
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The use of MRI deformable image registration for CT-based brachytherapy in locally advanced cervical cancer.
    Tait LM; Hoffman D; Benedict S; Valicenti R; Mayadev JS
    Brachytherapy; 2016; 15(3):333-340. PubMed ID: 26882845
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transrectal ultrasound for image-guided adaptive brachytherapy in cervix cancer - An alternative to MRI for target definition?
    Schmid MP; Nesvacil N; Pötter R; Kronreif G; Kirisits C
    Radiother Oncol; 2016 Sep; 120(3):467-472. PubMed ID: 26921168
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Point A vs. HR-CTV D
    Harmon G; Diak A; Shea SM; Yacoub JH; Small W; Harkenrider MM
    Brachytherapy; 2016; 15(6):825-831. PubMed ID: 27693173
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of dose-volume analysis between standard Manchester plan and magnetic resonance image-based plan of intracavitary brachytherapy for uterine cervical cancer.
    Takenaka T; Yoshida K; Tachiiri S; Yamazaki H; Aramoto K; Furuya S; Yoshida M; Ban C; Tanaka E; Honda K
    J Radiat Res; 2012 Sep; 53(5):791-7. PubMed ID: 22843369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison and consensus guidelines for delineation of clinical target volume for CT- and MR-based brachytherapy in locally advanced cervical cancer.
    Viswanathan AN; Erickson B; Gaffney DK; Beriwal S; Bhatia SK; Lee Burnett O; D'Souza DP; Patil N; Haddock MG; Jhingran A; Jones EL; Kunos CA; Lee LJ; Lin LL; Mayr NA; Petersen I; Petric P; Portelance L; Small W; Strauss JB; Townamchai K; Wolfson AH; Yashar CM; Bosch W
    Int J Radiat Oncol Biol Phys; 2014 Oct; 90(2):320-8. PubMed ID: 25304792
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implications for dosimetric changes when introducing MR-guided brachytherapy for small volume cervix cancer: a comparison of CT and MR-based treatments in a single centre.
    Dempsey C; Govindarajulu G; Sridharan S; Capp A; O'Brien P
    Australas Phys Eng Sci Med; 2014 Dec; 37(4):705-12. PubMed ID: 25344886
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical feasibility of MR-assisted CT-based cervical brachytherapy using MR-to-CT deformable image registration.
    Dyer BA; Yuan Z; Qiu J; Shi L; Wright C; Benedict SH; Valicenti R; Mayadev JS; Rong Y
    Brachytherapy; 2020; 19(4):447-456. PubMed ID: 32327343
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Apparent diffusion coefficients in GEC ESTRO target volumes for image guided adaptive brachytherapy of locally advanced cervical cancer.
    Haack S; Pedersen EM; Jespersen SN; Kallehauge JF; Lindegaard JC; Tanderup K
    Acta Oncol; 2010 Oct; 49(7):978-83. PubMed ID: 20831485
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Image-guided adaptive brachytherapy in cervical cancer: Patterns of relapse by brachytherapy planning parameters.
    Chargari C; Mazeron R; Escande A; Maroun P; Dumas I; Martinetti F; Tafo-Guemnie A; Deutsch E; Morice P; Haie-Meder C
    Brachytherapy; 2016; 15(4):456-462. PubMed ID: 27180129
    [TBL] [Abstract][Full Text] [Related]  

  • 18. CT-guided intracavitary radiotherapy for cervical cancer: Comparison of conventional point A plan with clinical target volume-based three-dimensional plan using dose-volume parameters.
    Shin KH; Kim TH; Cho JK; Kim JY; Park SY; Park SY; Kim DY; Chie EK; Pyo HR; Cho KH
    Int J Radiat Oncol Biol Phys; 2006 Jan; 64(1):197-204. PubMed ID: 16169676
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of computed tomography and magnetic resonance imaging in cervical cancer brachytherapy: A systematic review.
    Wang F; Tang Q; Lv G; Zhao F; Jiang X; Zhu X; Li X; Yan S
    Brachytherapy; 2017; 16(2):353-365. PubMed ID: 27965118
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A dose-volume analysis of magnetic resonance imaging-aided high-dose-rate image-based interstitial brachytherapy for uterine cervical cancer.
    Yoshida K; Yamazaki H; Takenaka T; Kotsuma T; Yoshida M; Furuya S; Tanaka E; Uegaki T; Kuriyama K; Matsumoto H; Yamada S; Ban C
    Int J Radiat Oncol Biol Phys; 2010 Jul; 77(3):765-72. PubMed ID: 19836165
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.