118 related articles for article (PubMed ID: 27795721)
1. Hyperfractionation of HDR brachytherapy - influence on doses and biologically equivalent doses in clinical target volume and healthy tissues.
Skowronek J; Zwierzchowski G; Piotrowski T
J Contemp Brachytherapy; 2009 Jun; 1(2):109-116. PubMed ID: 27795721
[TBL] [Abstract][Full Text] [Related]
2. Optimization and it's influence on value of doses in HDR and PDR brachytherapy.
Skowronek J; Zwierzchowski G; Piotrowski T; Milecki P
Neoplasma; 2010; 57(4):369-76. PubMed ID: 20429630
[TBL] [Abstract][Full Text] [Related]
3. Values of biologically equivalent doses in healthy tissues: comparison of PDR and HDR brachytherapy techniques.
Skowronek J; Malicki J; Piotrowski T
Brachytherapy; 2010; 9(2):165-70. PubMed ID: 19879813
[TBL] [Abstract][Full Text] [Related]
4. Influence of length of interval between pulses in PDR brachytherapy (PDRBT) on value of Biologically Equivalent Dose (BED) in healthy tissues.
Skowronek J; Malicki J; Zwierzchowski G; Piotrowski T
J Contemp Brachytherapy; 2010 Jun; 2(2):64-70. PubMed ID: 27829847
[TBL] [Abstract][Full Text] [Related]
5. A simple method of obtaining equivalent doses for use in HDR brachytherapy.
Nag S; Gupta N
Int J Radiat Oncol Biol Phys; 2000 Jan; 46(2):507-13. PubMed ID: 10661360
[TBL] [Abstract][Full Text] [Related]
6. Clinical implications of incomplete repair parameters for rat spinal cord: the feasibility of large doses per fraction in PDR and HDR brachytherapy.
Pop LA; Millar WT; Visser AG; van der Kogel AJ
Int J Radiat Oncol Biol Phys; 2001 Sep; 51(1):215-26. PubMed ID: 11516872
[TBL] [Abstract][Full Text] [Related]
7. Comparison of biologically equivalent dose-volume parameters for the treatment of prostate cancer with concomitant boost IMRT versus IMRT combined with brachytherapy.
Pieters BR; van de Kamer JB; van Herten YR; van Wieringen N; D'Olieslager GM; van der Heide UA; Koning CC
Radiother Oncol; 2008 Jul; 88(1):46-52. PubMed ID: 18378028
[TBL] [Abstract][Full Text] [Related]
8. CT based 3-dimensional treatment planning of intracavitary brachytherapy for cancer of the cervix: comparison between dose-volume histograms and ICRU point doses to the rectum and bladder.
Hashim N; Jamalludin Z; Ung NM; Ho GF; Malik RA; Phua VC
Asian Pac J Cancer Prev; 2014; 15(13):5259-64. PubMed ID: 25040985
[TBL] [Abstract][Full Text] [Related]
9. Radiobiological optimization comparison between pulse-dose-rate and high-dose-rate brachytherapy in patients with locally advanced cervical cancer.
Annede P; Dumas I; Schernberg A; Tailleur A; Fumagalli I; Bockel S; Mignot F; Kissel M; Deutsch E; Haie-Meder C; Chargari C
Brachytherapy; 2019; 18(3):370-377. PubMed ID: 30797698
[TBL] [Abstract][Full Text] [Related]
10. Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity.
Akimoto T; Ito K; Saitoh J; Noda SE; Harashima K; Sakurai H; Nakayama Y; Yamamoto T; Suzuki K; Nakano T; Niibe H
Int J Radiat Oncol Biol Phys; 2005 Oct; 63(2):463-71. PubMed ID: 16168838
[TBL] [Abstract][Full Text] [Related]
11. Treatment planning for MRI assisted brachytherapy of gynecologic malignancies based on total dose constraints.
Lang S; Kirisits C; Dimopoulos J; Georg D; Pötter R
Int J Radiat Oncol Biol Phys; 2007 Oct; 69(2):619-27. PubMed ID: 17869676
[TBL] [Abstract][Full Text] [Related]
12. The optimal fraction size in high-dose-rate brachytherapy: dependency on tissue repair kinetics and low-dose rate.
Sminia P; Schneider CJ; Fowler JF
Int J Radiat Oncol Biol Phys; 2002 Mar; 52(3):844-9. PubMed ID: 11849810
[TBL] [Abstract][Full Text] [Related]
13. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments.
Visser AG; van den Aardweg GJ; Levendag PC
Int J Radiat Oncol Biol Phys; 1996 Jan; 34(2):497-505. PubMed ID: 8567354
[TBL] [Abstract][Full Text] [Related]
14. Biological effect of pulsed dose rate brachytherapy with stepping sources if short half-times of repair are present in tissues.
Fowler JF; Van Limbergen EF
Int J Radiat Oncol Biol Phys; 1997 Mar; 37(4):877-83. PubMed ID: 9128965
[TBL] [Abstract][Full Text] [Related]
15. Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma.
Candela-Juan C; Perez-Calatayud J; Ballester F; Rivard MJ
Med Phys; 2013 Mar; 40(3):033901. PubMed ID: 23464344
[TBL] [Abstract][Full Text] [Related]
16. Biologically effective doses in medium dose rate brachytherapy of cancer of the cervix.
Leborgne F; Fowler JF; Leborgne JH; Zubizarreta E; Chappell R
Radiat Oncol Investig; 1997; 5(6):289-99. PubMed ID: 9436246
[TBL] [Abstract][Full Text] [Related]
17. Comparison of organ doses for patients undergoing balloon brachytherapy of the breast with HDR 192Ir or electronic sources using monte carlo simulations in a heterogeneous human phantom.
Mille MM; Xu XG; Rivard MJ
Med Phys; 2010 Feb; 37(2):662-71. PubMed ID: 20229875
[TBL] [Abstract][Full Text] [Related]
18. Literature analysis of high dose rate brachytherapy fractionation schedules in the treatment of cervical cancer: is there an optimal fractionation schedule?
Petereit DG; Pearcey R
Int J Radiat Oncol Biol Phys; 1999 Jan; 43(2):359-66. PubMed ID: 10030262
[TBL] [Abstract][Full Text] [Related]
19. Optimum fractionation for high-dose-rate endoesophageal brachytherapy following external irradiation of early stage esophageal cancer.
Akagi Y; Hirokawa Y; Kagemoto M; Matsuura K; Ito A; Fujita K; Kenjo M; Kiriu H; Ito K
Int J Radiat Oncol Biol Phys; 1999 Feb; 43(3):525-30. PubMed ID: 10078632
[TBL] [Abstract][Full Text] [Related]
20. Effectiveness of two different HDR brachytherapy regimens with the same BED value in cervical cancer.
Passi K; Kehwar TS; Mittal M; Singh B; Vashistha R; Gupta SJ; Yakhmi JV
J Contemp Brachytherapy; 2010 Jun; 2(2):53-60. PubMed ID: 27829845
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]