These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 27797010)

  • 21. Successful delivery of polytetrafluoroethylene-covered stent using rapid exchange guide extension catheter.
    Fujimoto Y; Tonoike N; Kobayashi Y
    Cardiovasc Interv Ther; 2017 Apr; 32(2):142-145. PubMed ID: 26815132
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Successful deployment of polytetrafluoroethylene-covered stent to seal left internal mammary artery graft perforation due to guide catheter extension system.
    Ichimoto E; De Gregorio J
    Cardiovasc Revasc Med; 2016 Dec; 17(8):574-577. PubMed ID: 27394179
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of the GuideLiner catheter for the treatment of a bifurcational total occlusion of the native left anterior descending artery through a tortuous composite venous graft.
    Hanna EB; Dasari TW; Hennebry TA
    J Invasive Cardiol; 2011 Mar; 23(3):E40-2. PubMed ID: 21364246
    [TBL] [Abstract][Full Text] [Related]  

  • 24. "Seesaw balloon-wire cutting" technique is superior to Tornus catheter in balloon uncrossable chronic total occlusions.
    Xue J; Li J; Wang H; Sheng L; Gong Y; Sun D; Li S; Li W; Wang D; Li Y
    Int J Cardiol; 2017 Feb; 228():523-527. PubMed ID: 27875729
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Successful percutaneous coronary intervention with GuideLiner® catheter for subtotal occlusive lesion in the right coronary artery with anomalous origin from the left sinus of Valsalva: a case report.
    Shirota A; Nomura T; Kubota H; Taminishi S; Urata R; Sugimoto T; Higuchi Y; Kato T; Keira N; Tatsumi T
    J Med Case Rep; 2015 Jul; 9():163. PubMed ID: 26215969
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention.
    Waterbury TM; Sorajja P; Bell MR; Lennon RJ; Mathew V; Singh M; Sandhu GS; Gulati R
    Catheter Cardiovasc Interv; 2016 Dec; 88(7):1057-1065. PubMed ID: 26698371
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A new technique for coronary guide catheter exchange over coronary guidewire using GuideLiner catheter.
    Stys TP; Khan MA; Rajpurohit N; Stys AT
    J Invasive Cardiol; 2014 May; 26(5):E56-8. PubMed ID: 24791727
    [TBL] [Abstract][Full Text] [Related]  

  • 28. "Incidence, clinical and angiographic characteristics, management and outcomes of coronary artery perforation at a high volume cardiac care center during percutaneous coronary intervention".
    Krishnegowda C; Puttegowda B; Krishnappa S; Ananthakrishna R; Mahadevappa NC; Siddegowda SK; Ramegowda RT; Manjunath CN
    Indian Heart J; 2020; 72(4):232-238. PubMed ID: 32861375
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Zambomballooning: A novel technique to seal a coronary perforation complicating the intervention of a chronic total occlusion.
    Gutiérrez-Chico JL
    Cardiol J; 2017; 24(5):573-575. PubMed ID: 29087536
    [No Abstract]   [Full Text] [Related]  

  • 30. Novel approach to coronary artery perforation repair.
    Ingrassia J; Youn YJ; Lee J; Azrin M; Khalid S
    Catheter Cardiovasc Interv; 2019 Feb; 93(2):E98-E100. PubMed ID: 30196541
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The GuideLiner-Sleeve Technique: A Novel Technique for High-Risk PCI Using Two Left Main Guides for Orbital Atherectomy of Two-Vessel Calcified Ostial Coronary Artery Disease.
    Hafiz AM; Smith C; Kakouros N
    J Invasive Cardiol; 2017 Nov; 29(11):E159-E160. PubMed ID: 29086733
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Triple-Guidewire Technique for Treating Stent Underexpansion in Severely Calcified Coronary Artery Lesions.
    Gedela M; Li S; Desai C; Stys T; Stys A
    Tex Heart Inst J; 2020 Apr; 47(2):155-159. PubMed ID: 32603468
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Mother-and-Child Catheter-Induced Retrograde Dissection of the Left Main Coronary Artery During Optical Coherence Tomography Examination.
    Chi WK; Yan BP; Chan CY
    J Invasive Cardiol; 2018 Jul; 30(7):E57-E58. PubMed ID: 29958179
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Distal coronary perforation in patients with prior coronary artery bypass graft surgery: The importance of early treatment.
    Karatasakis A; Akhtar YN; Brilakis ES
    Cardiovasc Revasc Med; 2016 Sep; 17(6):412-7. PubMed ID: 27465517
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Optical coherence tomography imaging after successful percutaneous coronary intervention treatment of coronary perforation following bioabsorbable vascular scaffold implantation: Consecutive ping-pong and child-in-mother techniques.
    Cortés C; Amat-Santos IJ; Jaguszewski M; Rojas P; Gonçalves LR; Gutiérrez-Chico JL; San Román JA
    Cardiol J; 2016; 23(4):413-5. PubMed ID: 27531492
    [No Abstract]   [Full Text] [Related]  

  • 36. Sealing of a dual feeding coronary artery perforation with homemade spring guidewire.
    Hartono B; Widito S; Munawar M
    Cardiovasc Interv Ther; 2015 Oct; 30(4):347-50. PubMed ID: 25301012
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Challenges associated with use of the GuideLiner catheter in percutaneous coronary interventions.
    Papayannis AC; Michael TT; Brilakis ES
    J Invasive Cardiol; 2012 Jul; 24(7):370-1. PubMed ID: 22781481
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Delayed appearance of coronary artery perforation following cutting balloon angioplasty.
    Maruo T; Yasuda S; Miyazaki S
    Catheter Cardiovasc Interv; 2002 Dec; 57(4):529-31. PubMed ID: 12455089
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Clinical Characteristics and Management of Coronary Artery Perforations: A Single-Center 11-Year Experience and Practical Overview.
    Lemmert ME; van Bommel RJ; Diletti R; Wilschut JM; de Jaegere PP; Zijlstra F; Daemen J; Van Mieghem NM
    J Am Heart Assoc; 2017 Sep; 6(9):. PubMed ID: 28939719
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical Outcomes of Self-Made Polyurethane-Covered Stent Implantation for the Treatment of Coronary Artery Perforations.
    Song X; Qin Q; Chang S; Xu R; Fu M; Lu H; Ge L; Qian J; Ma J; Ge J
    J Interv Cardiol; 2021; 2021():6661763. PubMed ID: 34104120
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.