These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 27802704)

  • 1. X-ray reflectometer for single layer and multilayer coating characterization at 8 keV: An interlaboratory study.
    Gurgew DN; Broadway DM; Gubarev M; Ramsey BD; Gregory DA
    Rev Sci Instrum; 2016 Oct; 87(10):104501. PubMed ID: 27802704
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Laboratory-based X-ray reflectometer for multilayer characterization in the 15-150 keV energy band.
    Windt DL
    Rev Sci Instrum; 2015 Apr; 86(4):043107. PubMed ID: 25933841
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combination of grazing incidence x-ray fluorescence with x-ray reflectivity in one table-top spectrometer for improved characterization of thin layer and implants on/in silicon wafers.
    Ingerle D; Schiebl M; Streli C; Wobrauschek P
    Rev Sci Instrum; 2014 Aug; 85(8):083110. PubMed ID: 25173249
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Platinum/carbon multilayer reflectors for soft-x-ray optics.
    Lodha GS; Yamashita K; Suzuki T; Hatsukade I; Tamura K; Ishigami T; Takahama S; Namba Y
    Appl Opt; 1994 Sep; 33(25):5869-74. PubMed ID: 20935990
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A quick convergent-beam laboratory X-ray reflectometer using a simultaneous multiple-angle dispersive geometry.
    Voegeli W; Kamezawa C; Arakawa E; Yano YF; Shirasawa T; Takahashi T; Matsushita T
    J Appl Crystallogr; 2017 Apr; 50(Pt 2):570-575. PubMed ID: 30319318
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Applications of non-periodic multilayer optics for high-resolution x-ray microscopes below 30 keV.
    Troussel P; Dennetiere D; Rousseau A; Darbon S; Høghøj P; Hedacq S; Krumrey M
    Rev Sci Instrum; 2012 Oct; 83(10):10E533. PubMed ID: 23127039
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A versatile beamline for soft x-ray reflectivity, absorption, and fluorescence measurements at Indus-2 synchrotron source.
    Modi MH; Gupta R; Gupta S; Yadav PK; Kant C; Lal S; Raghuvanshi VK; Kane SR
    Rev Sci Instrum; 2024 Feb; 95(2):. PubMed ID: 38364036
    [TBL] [Abstract][Full Text] [Related]  

  • 8. X-ray broadband Ni/SiC multilayers: improvement with W barrier layers.
    Emprin B; Troussel P; Soullié G; Stemmler P; Mercère P; Meltchakov E; Jérôme A; Delmotte F
    Opt Express; 2014 Oct; 22(21):25853-65. PubMed ID: 25401618
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous measurements of X-ray reflectivity and grazing incidence fluorescence at BL-16 beamline of Indus-2.
    Das G; Kane SR; Khooha A; Singh AK; Tiwari MK
    Rev Sci Instrum; 2015 May; 86(5):055102. PubMed ID: 26026553
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Soft X-ray reflectometer with laser produced plasma source].
    Chen B; Ni QL; Cao JH
    Guang Pu Xue Yu Guang Pu Fen Xi; 2005 Mar; 25(3):453-5. PubMed ID: 16013331
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of Co/Ti multilayers in a water window soft x-ray regime.
    Sarkar P; Biswas A; De R; Divakar Rao K; Ghosh S; Modi MH; John S; Barshilia HC; Bhattacharyya D; Sahoo NK
    Appl Opt; 2017 Sep; 56(27):7525-7532. PubMed ID: 29047727
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of energy response for photon-counting detectors using x-ray fluorescence.
    Ding H; Cho HM; Barber WC; Iwanczyk JS; Molloi S
    Med Phys; 2014 Dec; 41(12):121902. PubMed ID: 25471962
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hard x-ray spectrometer calibrations using a portable 120 kV x-ray source.
    Seely JF
    Rev Sci Instrum; 2022 Sep; 93(9):093529. PubMed ID: 36182475
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vacuum-compatible photon-counting hybrid pixel detector for wide-angle x-ray scattering, x-ray diffraction, and x-ray reflectometry in the tender x-ray range.
    Skroblin D; Schavkan A; Pflüger M; Pilet N; Lüthi B; Krumrey M
    Rev Sci Instrum; 2020 Feb; 91(2):023102. PubMed ID: 32113456
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector.
    Russo P; Mettivier G
    Med Phys; 2011 Apr; 38(4):2099-115. PubMed ID: 21626943
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultra-precision fabrication of 500 mm long and laterally graded Ru/C multilayer mirrors for X-ray light sources.
    Störmer M; Gabrisch H; Horstmann C; Heidorn U; Hertlein F; Wiesmann J; Siewert F; Rack A
    Rev Sci Instrum; 2016 May; 87(5):051804. PubMed ID: 27250371
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging.
    Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A
    Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Development of soft X-ray multilayer mirror at 23.4 nm].
    Liu Z; Li X; Ma YY; Chen B; Cao JL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2011 Apr; 31(4):1138-41. PubMed ID: 21714278
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Depth-graded Mo/Si multilayer coatings for hard x-rays.
    Burcklen C; Pardini T; Alameda J; Robinson J; Platonov Y; Walton C; Soufli R
    Opt Express; 2019 Mar; 27(5):7291-7306. PubMed ID: 30876295
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Soft X-Ray/EUV Reflectometer Based on a Laser Produced Plasma Source.
    Gullikson EM; Underwood JH; Batson PC; Nikitin V
    J Xray Sci Technol; 1992 Jan; 3(4):283-99. PubMed ID: 21307445
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.