199 related articles for article (PubMed ID: 27804922)
1. egs_brachy: a versatile and fast Monte Carlo code for brachytherapy.
Chamberland MJ; Taylor RE; Rogers DW; Thomson RM
Phys Med Biol; 2016 Dec; 61(23):8214-8231. PubMed ID: 27804922
[TBL] [Abstract][Full Text] [Related]
2. Update of the CLRP TG-43 parameter database for low-energy brachytherapy sources.
Safigholi H; Chamberland MJP; Taylor REP; Allen CH; Martinov MP; Rogers DWO; Thomson RM
Med Phys; 2020 Sep; 47(9):4656-4669. PubMed ID: 32436344
[TBL] [Abstract][Full Text] [Related]
3. Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources.
Safigholi H; Chamberland MJP; Taylor REP; Martinov MP; Rogers DWO; Thomson RM
Med Phys; 2023 Mar; 50(3):1928-1941. PubMed ID: 36542404
[TBL] [Abstract][Full Text] [Related]
4. Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'.
Yegin G
Phys Med Biol; 2018 Feb; 63(3):038001. PubMed ID: 29192610
[TBL] [Abstract][Full Text] [Related]
5. Update of the CLRP eye plaque brachytherapy database for photon-emitting sources.
Safigholi H; Parsons Z; Deering SG; Thomson RM
Med Phys; 2021 Jun; 48(6):3373-3283. PubMed ID: 33735471
[TBL] [Abstract][Full Text] [Related]
6. Monte Carlo Study on Dose Distributions Around
Mishra S; Mishra B; Selvam TP; Deshpande S; Pathan MS; Kumar R
J Med Phys; 2022; 47(3):270-278. PubMed ID: 36684701
[TBL] [Abstract][Full Text] [Related]
7. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for
Assam I; Vijande J; Ballester F; Pérez-Calatayud J; Poppe B; Siebert FA
Med Phys; 2022 Sep; 49(9):6195-6208. PubMed ID: 35925023
[TBL] [Abstract][Full Text] [Related]
9. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
[TBL] [Abstract][Full Text] [Related]
10. Fast GPU-based Monte Carlo simulations for LDR prostate brachytherapy.
Bonenfant É; Magnoux V; Hissoiny S; Ozell B; Beaulieu L; Després P
Phys Med Biol; 2015 Jul; 60(13):4973-86. PubMed ID: 26061145
[TBL] [Abstract][Full Text] [Related]
11. The use of tetrahedral mesh geometries in Monte Carlo simulation of applicator based brachytherapy dose distributions.
Fonseca GP; Landry G; White S; D'Amours M; Yoriyaz H; Beaulieu L; Reniers B; Verhaegen F
Phys Med Biol; 2014 Oct; 59(19):5921-35. PubMed ID: 25210788
[TBL] [Abstract][Full Text] [Related]
12. Dosimetry of a sonolucent material for an ultrasound-compatible gynecologic high-dose-rate brachytherapy cylinder using Monte Carlo simulation and radiochromic film.
Van Elburg DJ; Roumeliotis M; Morrison H; Rodgers JR; Fenster A; Meyer T
Brachytherapy; 2021; 20(1):265-271. PubMed ID: 33039331
[TBL] [Abstract][Full Text] [Related]
13. ARCHERRT - a GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: software development and application to helical tomotherapy.
Su L; Yang Y; Bednarz B; Sterpin E; Du X; Liu T; Ji W; Xu XG
Med Phys; 2014 Jul; 41(7):071709. PubMed ID: 24989378
[TBL] [Abstract][Full Text] [Related]
14. Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG
Reddy BR; Chamberland MJP; Ravikumar M; Varatharaj C
J Contemp Brachytherapy; 2019 Dec; 11(6):563-572. PubMed ID: 31969915
[TBL] [Abstract][Full Text] [Related]
15. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition.
Landry G; Reniers B; Murrer L; Lutgens L; Gurp EB; Pignol JP; Keller B; Beaulieu L; Verhaegen F
Med Phys; 2010 Oct; 37(10):5188-98. PubMed ID: 21089752
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.
Lesperance M; Martinov M; Thomson RM
Med Phys; 2014 Mar; 41(3):031706. PubMed ID: 24593710
[TBL] [Abstract][Full Text] [Related]
17. Experimental Determination of Radial Dose Function and Anisotropy Function of GammaMed Plus
Buchapudi RR; Manickam R; Chandaraj V
J Med Phys; 2019; 44(4):246-253. PubMed ID: 31908383
[TBL] [Abstract][Full Text] [Related]
18. Advanced Collapsed cone Engine dose calculations in tissue media for COMS eye plaques loaded with I-125 seeds.
Morrison H; Menon G; Larocque MP; van Veelen B; Niatsetski Y; Weis E; Sloboda RS
Med Phys; 2018 Jul; 45(7):3349-3360. PubMed ID: 29729009
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo simulation of the effect of magnetic fields on brachytherapy dose distributions in lung tissue material.
Moreno-Barbosa F; de Celis-Alonso B; Moreno-Barbosa E; Hernández-López JM; Geoghegan T; Ramos-Méndez J
PLoS One; 2020; 15(10):e0238704. PubMed ID: 33035214
[TBL] [Abstract][Full Text] [Related]
20. Fast beta-emitter Monte Carlo simulations and full patient dose calculations of targeted radionuclide therapy: introducing egs_mird.
Martinov MP; Opara C; Thomson RM; Lee TY
Med Phys; 2022 Sep; 49(9):6137-6149. PubMed ID: 35650012
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]