These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 27805155)

  • 1. Standardization of
    Zimmerman BE; Collé R
    J Res Natl Inst Stand Technol; 1997; 102(4):455-477. PubMed ID: 27805155
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A liquid-scintillation-based primary standardization of 210Pb.
    Laureano-Pérez L; Collé R; Fitzgerald R; Outola I; Pibida L
    Appl Radiat Isot; 2007 Dec; 65(12):1368-80. PubMed ID: 17766125
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The standardization of 177Lu by 4pibeta liquid scintillation spectrometry with 3H-standard efficiency tracing.
    Zimmerman BE; Unterweger MP; Brodack JW
    Appl Radiat Isot; 2001 Apr; 54(4):623-31. PubMed ID: 11225698
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation into the standardization of 99Tc.
    Laureano-Perez L; Collé R; Fitzgerald R; Zimmerman BE; Cumberland L
    Appl Radiat Isot; 2010; 68(7-8):1489-94. PubMed ID: 20060309
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The standardization of 188W/188Re by 4pi beta liquid scintillation spectrometry with the CIEMAT/NIST 3H-standard efficiency tracing method.
    Zimmerman BE; Cessna JT; Unterweger MP
    Appl Radiat Isot; 2002; 56(1-2):315-20. PubMed ID: 11839034
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of tritiated-water standards by liquid scintillation for calibration of a new Standard Reference Material®.
    Collé R; Laureano-Perez L; Bergeron DE
    Appl Radiat Isot; 2016 Jun; 112():38-49. PubMed ID: 27010939
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Preparation and Calibration of Carrier-Free
    Collé R; Lin Z; Schima FJ; Hodge PA; Thomas JWL; Hutchinson JMR; Coursey BM
    J Res Natl Inst Stand Technol; 1995; 100(1):1-36. PubMed ID: 29151724
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Compendium on the NIST Radionuclidic Assays of the Massic Activity of
    Collé R; Zimmerman BE
    J Res Natl Inst Stand Technol; 1997; 102(5):523-549. PubMed ID: 27805141
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Standardization of
    Kulkarni DB; Joseph L; Anuradha R; Kulkarni MS; Tomar BS
    Appl Radiat Isot; 2017 May; 123():6-10. PubMed ID: 28189091
    [No Abstract]   [Full Text] [Related]  

  • 10. Development of liquid scintillation based 4πβ(LS)-γ coincidence counting system and demonstration of its performance by standardization of ⁶⁰Co.
    Kulkarni DB; Anuradha R; Joseph L; Tomar BS
    Appl Radiat Isot; 2013 Feb; 72():68-72. PubMed ID: 23208234
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the French and U.S. national 3H (tritiated H2O) standards by 4 pi beta liquid scintillation spectrometry.
    Zimmerman BE; Collé R
    Appl Radiat Isot; 1997 Apr; 48(4):521-6. PubMed ID: 9106992
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Standardization of ²³⁷Np.
    Laureano-Perez L; Fitzgerald R; Collé R
    Appl Radiat Isot; 2014 May; 87():269-73. PubMed ID: 24378363
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an Ultra-Pure, Carrier-Free (209)Po Solution Standard.
    Collé R; Fitzgerald RP; Laureano-Perez L
    J Res Natl Inst Stand Technol; 2015; 120():138-63. PubMed ID: 26958444
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Standardization of (68)Ge/(68)Ga Using Three Liquid Scintillation Counting Based Methods.
    Zimmerman BE; Cessna JT; Fitzgerald R
    J Res Natl Inst Stand Technol; 2008; 113(5):265-80. PubMed ID: 27096126
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new NIST primary standardization of 18F.
    Fitzgerald R; Zimmerman BE; Bergeron DE; Cessna JC; Pibida L; Moreira DS
    Appl Radiat Isot; 2014 Feb; 85():77-84. PubMed ID: 24384397
    [TBL] [Abstract][Full Text] [Related]  

  • 16.
    Collé R; Thomas JW
    J Res Natl Inst Stand Technol; 1993; 98(6):653-677. PubMed ID: 28053491
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Standardization of ¹³¹I: implementation of CIEMAT/NIST method at BARC, India.
    Kulkarni DB; Anuradha R; Reddy PJ; Joseph L
    Appl Radiat Isot; 2011 Oct; 69(10):1512-5. PubMed ID: 21757363
    [TBL] [Abstract][Full Text] [Related]  

  • 18.
    da Silva CJ; da Cruz PAL; Iwahara A; Loureiro JDS; Gomes RDS; Dos Santos ARL; de Araújo MTF; Poledna R; da Silva RL; Laranjeira ADS
    Appl Radiat Isot; 2018 Apr; 134():316-320. PubMed ID: 29107514
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 63Ni, its half-life and standardization: revisited.
    Collé R; Zimmerman BE; Cassette P; Laureano-Perez L
    Appl Radiat Isot; 2008 Jan; 66(1):60-8. PubMed ID: 17766127
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a primary standard for calibration of (64)Cu activity measurement systems.
    Capogni M; De Felice P; Fazio A; Latini F; Abbas K
    Appl Radiat Isot; 2008; 66(6-7):948-53. PubMed ID: 18372184
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.