These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 27811403)

  • 1. Prioritized efficiency optimization for intensity modulated proton therapy.
    Müller BS; Wilkens JJ
    Phys Med Biol; 2016 Dec; 61(23):8249-8265. PubMed ID: 27811403
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shortening delivery times of intensity modulated proton therapy by reducing proton energy layers during treatment plan optimization.
    van de Water S; Kooy HM; Heijmen BJ; Hoogeman MS
    Int J Radiat Oncol Biol Phys; 2015 Jun; 92(2):460-8. PubMed ID: 25823447
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of linear and nonlinear programming approaches for "worst case dose" and "minmax" robust optimization of intensity-modulated proton therapy dose distributions.
    Zaghian M; Cao W; Liu W; Kardar L; Randeniya S; Mohan R; Lim G
    J Appl Clin Med Phys; 2017 Mar; 18(2):15-25. PubMed ID: 28300378
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy.
    Ding X; Li X; Zhang JM; Kabolizadeh P; Stevens C; Yan D
    Int J Radiat Oncol Biol Phys; 2016 Dec; 96(5):1107-1116. PubMed ID: 27869083
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.
    Gu W; O'Connor D; Nguyen D; Yu VY; Ruan D; Dong L; Sheng K
    Med Phys; 2018 Apr; 45(4):1338-1350. PubMed ID: 29394454
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Shortening delivery times for intensity-modulated proton therapy by reducing the number of proton spots: an experimental verification.
    van de Water S; Belosi MF; Albertini F; Winterhalter C; Weber DC; Lomax AJ
    Phys Med Biol; 2020 May; 65(9):095008. PubMed ID: 32155594
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Robust optimization for intensity-modulated proton therapy with soft spot sensitivity regularization.
    Gu W; Ruan D; O'Connor D; Zou W; Dong L; Tsai MY; Jia X; Sheng K
    Med Phys; 2019 Mar; 46(3):1408-1425. PubMed ID: 30570164
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.
    Liu C; Schild SE; Chang JY; Liao Z; Korte S; Shen J; Ding X; Hu Y; Kang Y; Keole SR; Sio TT; Wong WW; Sahoo N; Bues M; Liu W
    Int J Radiat Oncol Biol Phys; 2018 Jun; 101(2):479-489. PubMed ID: 29550033
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Robust optimization to reduce the impact of biological effect variation from physical uncertainties in intensity-modulated proton therapy.
    Bai X; Lim G; Grosshans D; Mohan R; Cao W
    Phys Med Biol; 2019 Jan; 64(2):025004. PubMed ID: 30523932
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Energy layer optimization strategies for intensity-modulated proton therapy of lung cancer patients.
    Jensen MF; Hoffmann L; Petersen JBB; Møller DS; Alber M
    Med Phys; 2018 Oct; 45(10):4355-4363. PubMed ID: 30129041
    [TBL] [Abstract][Full Text] [Related]  

  • 11. TriB-RT: Simultaneous optimization of photon, electron and proton beams.
    Kueng R; Mueller S; Loebner HA; Frei D; Volken W; Aebersold DM; Stampanoni MFM; Fix MK; Manser P
    Phys Med Biol; 2021 Feb; 66(4):045006. PubMed ID: 32413883
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combined optimization of spot positions and weights for better FLASH proton therapy.
    Lansonneur P; Magliari A; Rosa L; Perez J; Niemelä P; Folkerts M
    Phys Med Biol; 2024 Jun; 69(12):. PubMed ID: 38749462
    [No Abstract]   [Full Text] [Related]  

  • 13. Adaptive method for multicriteria optimization of intensity-modulated proton therapy.
    Kamal-Sayed H; Ma J; Tseung H; Abdel-Rehim A; Herman MG; Beltran CJ
    Med Phys; 2018 Dec; 45(12):5643-5652. PubMed ID: 30332515
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Can differences in linear energy transfer and thus relative biological effectiveness compromise the dosimetric advantage of intensity-modulated proton therapy as compared to passively scattered proton therapy?
    Giantsoudi D; Adams J; MacDonald S; Paganetti H
    Acta Oncol; 2018 Sep; 57(9):1259-1264. PubMed ID: 29726722
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.
    Shan J; Sio TT; Liu C; Schild SE; Bues M; Liu W
    Med Phys; 2019 Jan; 46(1):382-393. PubMed ID: 30387870
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Statistical evaluation of worst-case robust optimization intensity-modulated proton therapy plans using an exhaustive sampling approach.
    Yang Z; Li H; Li Y; Li Y; Chang Y; Li Q; Yang K; Wu G; Sahoo N; Poenisch F; Gillin M; Zhu XR; Zhang X
    Radiat Oncol; 2019 Jul; 14(1):129. PubMed ID: 31324257
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Linear energy transfer incorporated intensity modulated proton therapy optimization.
    Cao W; Khabazian A; Yepes PP; Lim G; Poenisch F; Grosshans DR; Mohan R
    Phys Med Biol; 2017 Dec; 63(1):015013. PubMed ID: 29131808
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of spot parameters in pencil beam scanning treatment planning.
    Kraan AC; Depauw N; Clasie B; Giunta M; Madden T; Kooy HM
    Med Phys; 2018 Jan; 45(1):60-73. PubMed ID: 29148575
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A dosimetric comparison of intensity-modulated proton therapy optimization techniques for pediatric craniopharyngiomas: a clinical case study.
    Yeung D; McKenzie C; Indelicato DJ
    Pediatr Blood Cancer; 2014 Jan; 61(1):89-94. PubMed ID: 24000229
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Pareto-based beam orientation optimization method for spot scanning intensity-modulated proton therapy.
    Kamal Sayed H; Herman MG; Beltran CJ
    Med Phys; 2020 Jun; 47(5):2049-2060. PubMed ID: 32077497
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.