BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1251 related articles for article (PubMed ID: 27818186)

  • 1. Fixation of 4-part fractures of the proximal humerus: Can we identify radiological criteria that support locking plates or IM nailing? Comparative, retrospective study of 107 cases.
    Gadea F; Favard L; Boileau P; Cuny C; d'Ollone T; Saragaglia D; Sirveaux F;
    Orthop Traumatol Surg Res; 2016 Dec; 102(8):963-970. PubMed ID: 27818186
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Locking plate fixation versus antegrade nailing of 3- and 4-part proximal humerus fractures in patients without osteoporosis. Comparative retrospective study of 63 cases.
    Boudard G; Pomares G; Milin L; Lemonnier I; Coudane H; Mainard D; Delagoutte JP
    Orthop Traumatol Surg Res; 2014 Dec; 100(8):917-24. PubMed ID: 25453929
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Unreamed locking intramedullary nailing of humeral fractures--basic evaluation of a patient group].
    Fric V; Pazdírek P; Bartonícek J
    Acta Chir Orthop Traumatol Cech; 2001; 68(6):345-56. PubMed ID: 11847926
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome.
    Solberg BD; Moon CN; Franco DP; Paiement GD
    J Orthop Trauma; 2009 Feb; 23(2):113-9. PubMed ID: 19169103
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®.
    Helfen T; Siebenbürger G; Mayer M; Böcker W; Ockert B; Haasters F
    BMC Musculoskelet Disord; 2016 Oct; 17(1):448. PubMed ID: 27793135
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy.
    Wang M; Wang X; Cai P; Guo S; Fu B
    BMC Musculoskelet Disord; 2023 Jun; 24(1):461. PubMed ID: 37277746
    [TBL] [Abstract][Full Text] [Related]  

  • 7. What Factors Are Associated With Poor Shoulder Function and Serious Complications After Internal Fixation of Three-part and Four-part Proximal Humerus Fracture-dislocations?
    Gavaskar AS; Pattabiraman K; Srinivasan P; Raj RV; Jayakumar B; Rangasamy NK
    Clin Orthop Relat Res; 2022 Aug; 480(8):1566-1573. PubMed ID: 35333197
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Which additional augmented fixation procedure decreases surgical failure after proximal humeral fracture with medial comminution: fibular allograft or inferomedial screws?
    Kim DS; Lee DH; Chun YM; Shin SJ
    J Shoulder Elbow Surg; 2018 Oct; 27(10):1852-1858. PubMed ID: 29735375
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Three-dimensional finite element analysis of exo-cortical placement of humeral calcar screw for reconstruction of medial column stability].
    Li B; Chang S; Hu S; Du S; Xiong W
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Aug; 36(8):995-1002. PubMed ID: 35979792
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Displaced humeral surgical neck fractures: classification and results of third-generation percutaneous intramedullary nailing.
    Boileau P; d'Ollonne T; Bessière C; Wilson A; Clavert P; Hatzidakis AM; Chelli M
    J Shoulder Elbow Surg; 2019 Feb; 28(2):276-287. PubMed ID: 30429058
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Internal fixation of proximal humerus fractures using the locking proximal humerus plate.
    Plecko M; Kraus A
    Oper Orthop Traumatol; 2005 Feb; 17(1):25-50. PubMed ID: 16007377
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fractures and fracture-dislocations of the proximal humerus: A retrospective analysis of 82 cases treated with the Philos(®) locking plate.
    Erasmo R; Guerra G; Guerra L
    Injury; 2014 Dec; 45 Suppl 6():S43-8. PubMed ID: 25457318
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Locking plate fixation of three- and four-part proximal humeral fractures.
    Parmaksizoğlu AS; Sökücü S; Ozkaya U; Kabukçuoğlu Y; Gül M
    Acta Orthop Traumatol Turc; 2010; 44(2):97-104. PubMed ID: 20676010
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hinge plate technique for osteosynthesis of comminuted proximal humeral fractures.
    Habib N; Fornaciari P; Thuerig G; Maniglio M; Tannast M; Vial P
    Injury; 2021 Aug; 52(8):2292-2299. PubMed ID: 34053774
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus.
    Hardeman F; Bollars P; Donnelly M; Bellemans J; Nijs S
    Injury; 2012 Feb; 43(2):153-8. PubMed ID: 21570073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Percutaneous plate fixation of displaced proximal humerus fractures: Do minimally invasive techniques improve outcomes and reduce complications?
    Garcia-Maya B; Pérez-Barragans F; Lainez Galvez JR; Paez Gallego J; Vaquero-Picado A; Barco R; Antuña S
    Injury; 2023 Dec; 54 Suppl 7():111042. PubMed ID: 38225161
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calcar comminution as prognostic factor of clinical outcome after locking plate fixation of proximal humeral fractures.
    Osterhoff G; Hoch A; Wanner GA; Simmen HP; Werner CM
    Injury; 2012 Oct; 43(10):1651-6. PubMed ID: 22579397
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does cement augmentation of the screws in angular stable plating for proximal humerus fractures influence the radiological outcome: a retrospective assessment.
    Knierzinger D; Crepaz-Eger U; Hengg C; Kralinger F
    Arch Orthop Trauma Surg; 2020 Oct; 140(10):1413-1421. PubMed ID: 32130479
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Complications encountered in proximal humerus fractures treated with locking plate fixation.
    Aksu N; Göğüş A; Kara AN; Işiklar ZU
    Acta Orthop Traumatol Turc; 2010; 44(2):89-96. PubMed ID: 20676009
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Locking nail versus locking plate for proximal humeral fracture fixation in an elderly population: a prospective randomised controlled trial.
    Plath JE; Kerschbaum C; Seebauer T; Holz R; Henderson DJH; Förch S; Mayr E
    BMC Musculoskelet Disord; 2019 Jan; 20(1):20. PubMed ID: 30630465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 63.