133 related articles for article (PubMed ID: 27821823)
1. [New Intracoronary Shunt Cannula in Off-pump Coronary Artery Bypass Grafting].
Tabuchi M; Harada R; Yamashita A; Funamoto S; Tachibana K; Miyaki Y; Takagi N; Terada S; Toritsuka D; Yamauchi A; Higami T
Kyobu Geka; 2016 Nov; 69(12):995-998. PubMed ID: 27821823
[TBL] [Abstract][Full Text] [Related]
2. A simple technique of introducing intracoronary shunts for off-pump coronary artery bypass surgery.
Yokoyama H; Takase S; Misawa Y; Takahashi K; Sato Y; Satokawa H
Ann Thorac Surg; 2004 Jul; 78(1):352-4. PubMed ID: 15223470
[TBL] [Abstract][Full Text] [Related]
3. Clinical validation of coronary artery flow through an intracoronary shunt during off-pump coronary artery bypass grafting.
Takami Y; Tajima K; Kato W; Fujii K; Hibino M; Munakata H; Sakai Y
J Thorac Cardiovasc Surg; 2014 Jan; 147(1):259-63. PubMed ID: 23141031
[TBL] [Abstract][Full Text] [Related]
4. Graft-to-coronary-artery shunt during off-pump coronary artery bypass grafting.
Iida H; Mori H; Sudo Y; Yamada Y; Eda K; Inoue Y
Ann Thorac Surg; 2006 Sep; 82(3):e27-8. PubMed ID: 16928480
[TBL] [Abstract][Full Text] [Related]
5. Intracoronary shunt versus bulldog clamp in off-pump bypass surgery. Endothelial trauma: shunt versus clamp.
Vural AH; Yalcinkaya S; Türk T; Yümün G; Gül N; Yalcinkaya U; Kaya M; Ozyazicioğlu A
J Surg Res; 2008 Dec; 150(2):261-5. PubMed ID: 18262555
[TBL] [Abstract][Full Text] [Related]
6. Intracoronary shunt prevents ischemia in off-pump coronary artery bypass surgery.
Bergsland J; Lingaas PS; Skulstad H; Hol PK; Halvorsen PS; Andersen R; Småstuen M; Lundblad R; Svennevig J; Andersen K; Fosse E
Ann Thorac Surg; 2009 Jan; 87(1):54-60. PubMed ID: 19101268
[TBL] [Abstract][Full Text] [Related]
7. A safe technique of exposing of a "hidden" left anterior descending artery.
Apostolakis E; Koletsis E; Leivaditis V; Lozos V; Dougenis D
J Card Surg; 2007; 22(6):505-6; discussion 507. PubMed ID: 18039213
[TBL] [Abstract][Full Text] [Related]
8. Influence of intracoronary shunt on myocardial ischemic injury during off-pump coronary artery bypass surgery.
Bozok S; İlhan G; Karamustafa H; Ozan Karakişi S; Tüfekçi N; Tomak Y; Bağci P; Emir M; Sener E
J Cardiovasc Surg (Torino); 2013 Apr; 54(2):289-95. PubMed ID: 23337405
[TBL] [Abstract][Full Text] [Related]
9. Protective role of intracoronary shunt in off-pump coronary bypass operations.
Tok M; Ucar HI; Dogan OF; Farsak B; Yorgancioglu AC
Saudi Med J; 2008 Apr; 29(4):573-9. PubMed ID: 18382802
[TBL] [Abstract][Full Text] [Related]
10. Techniques and results of off-pump coronary artery bypass grafting using homemade intracoronary shunt.
Chaiyaroj S; Viengteeravat S; Bhumarangura W; Khajarern S; Leelayana P; Purintrapiban B
J Med Assoc Thai; 2006 Sep; 89(9):1434-9. PubMed ID: 17100381
[TBL] [Abstract][Full Text] [Related]
11. Portable coronary active perfusion system for off-pump coronary artery bypass grafting.
Koshida Y; Watanabe G; Yasuda T; Tomita S; Kadoya S; Kanamori T
Ann Thorac Surg; 2006 Feb; 81(2):706-10. PubMed ID: 16427878
[TBL] [Abstract][Full Text] [Related]
12. [Off-pump coronary artery bypass grafting using graft to coronary shunt for acute coronary syndrome].
Iida H; Mori H; Yamada Y; Eda K; Inoue Y; Mochizuki Y
Kyobu Geka; 2005 Jun; 58(6):471-4. PubMed ID: 15957421
[TBL] [Abstract][Full Text] [Related]
13. Segmental clamp and distal perfusion technique for reducing myocardial ischemia during coronary onlay grafting on a beating heart.
Minato N; Okada T; Kanemoto S; Zempo N
Surg Today; 2018 May; 48(5):566-570. PubMed ID: 29318373
[TBL] [Abstract][Full Text] [Related]
14. Sutureless Technique to Fix the Great Saphenous Vein along the Atrioventricular Groove Using Fibrin Glue in Off-Pump Coronary Artery Bypass Grafting.
Ohira S; Doi K; Yaku H
Heart Surg Forum; 2016 Apr; 19(2):E074-6. PubMed ID: 27146234
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of a novel laser-assisted coronary anastomotic connector - the Trinity Clip - in a porcine off-pump bypass model.
Stecher D; Bronkers G; Noest JO; Tulleken CA; Hoefer IE; van Herwerden LA; Pasterkamp G; Buijsrogge MP
J Vis Exp; 2014 Nov; (93):e52127. PubMed ID: 25490000
[TBL] [Abstract][Full Text] [Related]
16. Off-pump coronary artery bypass grafting: the Zurich experience.
Tavakoli R; Reuthebuch O; Hofer C; Grünenfelder J; Genoni M
Heart Surg Forum; 2005; 8(4):E246-8. PubMed ID: 16112937
[TBL] [Abstract][Full Text] [Related]
17. Cerebrovascular Events After No-Touch Off-Pump Coronary Artery Bypass Grafting, Conventional Side-Clamp Off-Pump Coronary Artery Bypass, and Proximal Anastomotic Devices: A Meta-Analysis.
Pawliszak W; Kowalewski M; Raffa GM; Malvindi PG; Kowalkowska ME; Szwed KA; Borkowska A; Kowalewski J; Anisimowicz L
J Am Heart Assoc; 2016 Feb; 5(2):. PubMed ID: 26892526
[TBL] [Abstract][Full Text] [Related]
18. [A trial to improve operative results of coronary artery bypass grafting (CABG); off-pump CABG (OPCAB) as standard procedure].
Watanabe Y
Kyobu Geka; 2009 Jan; 62(1):24-7. PubMed ID: 19195182
[TBL] [Abstract][Full Text] [Related]
19. [Clinical studies in the effect of operative strategies on the hemodynamics in off-pump coronary artery bypass grafting].
Mei J; Wang YQ; Bao CR; Ding FB; Du QR; Xie X; Shen SE
Zhonghua Wai Ke Za Zhi; 2008 Feb; 46(4):241-4. PubMed ID: 18683755
[TBL] [Abstract][Full Text] [Related]
20. Perfusion flow assessment of coronary shunt during off-pump coronary artery bypass grafting.
Arai H; Kozakai A; Manabe S; Kawaguchi S; Shimizu M; Egi K; Tabuchi N; Tanaka H; Sunamori M
Heart Surg Forum; 2004 Apr; 7(2):E136-40. PubMed ID: 15138091
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]