221 related articles for article (PubMed ID: 27822592)
1. [Implantable loop recorder of the Confirm family (St. Jude Medical)].
Pujdak K
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):341-344. PubMed ID: 27822592
[TBL] [Abstract][Full Text] [Related]
2. [Implantable loop recorders of the Reveal family (Medtronic)].
Voss F
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):333-336. PubMed ID: 27878365
[TBL] [Abstract][Full Text] [Related]
3. [Implantable loop recorder BioMonitor 2 (Biotronik)].
Lewalter T; Jilek C
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):337-340. PubMed ID: 27848030
[TBL] [Abstract][Full Text] [Related]
4. [Implantable loop recorders in the diagnosis of syncope].
Kaess BM; Ehrlich JR
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):345-350. PubMed ID: 27812742
[TBL] [Abstract][Full Text] [Related]
5. [Indications for implantable loop recorders in patients with channelopathies and ventricular tachycardias].
Köbe J; Wasmer K; Reinke F; Eckardt L
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):360-365. PubMed ID: 27844191
[TBL] [Abstract][Full Text] [Related]
6. [Event recorder in cryptogenic stroke : Accepted and feasible indications].
Brachmann J; Held M
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):351-354. PubMed ID: 27844195
[TBL] [Abstract][Full Text] [Related]
7. [Diagnostic cardiovascular implants: Implantable loop recorder/pulmonary artery pressure sensor].
Schuchert A; Brachmann J
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):331-332. PubMed ID: 27783144
[No Abstract] [Full Text] [Related]
8. Performance of the New BioMonitor 2-AF Insertable Cardiac Monitoring System: Can Better be Worse?
Lacour P; Dang PL; Huemer M; Parwani AS; Attanasio P; Pieske B; Boldt LH; Haverkamp W; Blaschke F
Pacing Clin Electrophysiol; 2017 May; 40(5):516-526. PubMed ID: 28220938
[TBL] [Abstract][Full Text] [Related]
9. [Event-recorder].
Schuchert A
Herzschrittmacherther Elektrophysiol; 2008 Sep; 19(3):130-6. PubMed ID: 18956159
[TBL] [Abstract][Full Text] [Related]
10. [Implantable loop recorder in atrial fibrillation and after catheter ablation].
Fikenzer K; Dagres N; Hindricks G
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):355-359. PubMed ID: 27832334
[TBL] [Abstract][Full Text] [Related]
11. Current rare indications and future directions for implantable loop recorders.
Wechselberger S; Piorkowski C; Pohl M
Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):366-370. PubMed ID: 27873022
[TBL] [Abstract][Full Text] [Related]
12. Sensing performance of a new wireless implantable loop recorder: a 12-month follow up study.
Jacob S; Kommuri NV; Zalawadiya SK; Meissner MD; Lieberman RA
Pacing Clin Electrophysiol; 2010 Jul; 33(7):834-40. PubMed ID: 20132491
[TBL] [Abstract][Full Text] [Related]
13. Are implantable loop recorders useful in detecting arrhythmias in children with unexplained syncope?
Al Dhahri KN; Potts JE; Chiu CC; Hamilton RM; Sanatani S
Pacing Clin Electrophysiol; 2009 Nov; 32(11):1422-7. PubMed ID: 19694968
[TBL] [Abstract][Full Text] [Related]
14. Tachycardia detection performance of implantable loop recorders: results from a large 'real-life' patient cohort and patients with induced ventricular arrhythmias.
Volosin K; Stadler RW; Wyszynski R; Kirchhof P
Europace; 2013 Aug; 15(8):1215-22. PubMed ID: 23439867
[TBL] [Abstract][Full Text] [Related]
15. Miniaturized Implantable Loop Recorder in Small Patients: An Effective Approach to the Evaluation of Subjects at Risk of Sudden Death.
Placidi S; Drago F; Milioni M; Verticelli L; Tamburri I; Silvetti MS; DI Mambro C; Righi D; Gimigliano F; Russo MS; Palmieri R; Remoli R; Santucci LM; Tozzi AE
Pacing Clin Electrophysiol; 2016 Jul; 39(7):669-74. PubMed ID: 27062386
[TBL] [Abstract][Full Text] [Related]
16. Use of the insertable loop recorder to detect cardiac arrhythmias during syncopal episodes.
Reiff PA; Gutierrez JD
Medsurg Nurs; 2004 Apr; 13(2):105-9. PubMed ID: 15119423
[TBL] [Abstract][Full Text] [Related]
17. Extended ECG monitoring with an implantable loop recorder in patients with cryptogenic stroke: time schedule, reasons for explantation and incidental findings (results from the TRACK-AF trial).
Bettin M; Dechering D; Kochhäuser S; Bode N; Eckardt L; Frommeyer G; Reinke F
Clin Res Cardiol; 2019 Mar; 108(3):309-314. PubMed ID: 30167809
[TBL] [Abstract][Full Text] [Related]
18. Detection of atrial fibrillation in patients with embolic stroke of undetermined source by prolonged monitoring with implantable loop recorders.
Israel C; Kitsiou A; Kalyani M; Deelawar S; Ejangue LE; Rogalewski A; Hagemeister C; Minnerup J; Schäbitz WR
Thromb Haemost; 2017 Oct; 117(10):1962-1969. PubMed ID: 28862284
[TBL] [Abstract][Full Text] [Related]
19. Improved arrhythmia detection in implantable loop recorders.
Brignole M; Bellardine Black CL; Thomsen PE; Sutton R; Moya A; Stadler RW; Cao J; Messier M; Huikuri HV
J Cardiovasc Electrophysiol; 2008 Sep; 19(9):928-34. PubMed ID: 18410328
[TBL] [Abstract][Full Text] [Related]
20. A microcontroller-based portable electrocardiograph recorder.
Segura-Juárez JJ; Cuesta-Frau D; Samblas-Pena L; Aboy M
IEEE Trans Biomed Eng; 2004 Sep; 51(9):1686-90. PubMed ID: 15376519
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]