BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 2782645)

  • 1. Spinal needle determinants of rate of transdural fluid leak.
    Ready LB; Cuplin S; Haschke RH; Nessly M
    Anesth Analg; 1989 Oct; 69(4):457-60. PubMed ID: 2782645
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Electron microscopy of the lesions produced in the human dura mater by Quincke beveled and Whitacre needles].
    Reina MA; López-García A; de Andrés-Ibáñez JA; Dittmann M; Cascales MR; del Caño MC; Daneri J; Zambrano O
    Rev Esp Anestesiol Reanim; 1997 Feb; 44(2):56-61. PubMed ID: 9148357
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An in vitro comparison of fluid leakage after dural puncture with Atraucan, Sprotte, Whitacre, and Quincke needles.
    Morrison LM; McCrae AF; Foo I; Scott DB; Wildsmith JA
    Reg Anesth; 1996; 21(2):139-43. PubMed ID: 8829406
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An in vitro study of dural lesions produced by 25-gauge Quincke and Whitacre needles evaluated by scanning electron microscopy.
    Reina MA; de Leon-Casasola OA; Lopez A; De Andres J; Martin S; Mora M
    Reg Anesth Pain Med; 2000; 25(4):393-402. PubMed ID: 10925937
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dural tissue trauma and cerebrospinal fluid leak after epidural needle puncture: effect of needle design, angle, and bevel orientation.
    Angle PJ; Kronberg JE; Thompson DE; Ackerley C; Szalai JP; Duffin J; Faure P
    Anesthesiology; 2003 Dec; 99(6):1376-82. PubMed ID: 14639152
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Importance of the needle bevel during spinal and epidural anesthesia.
    Baumgarten RK
    Reg Anesth; 1995; 20(3):234-8. PubMed ID: 7547661
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Possibility of cauda equina nerve root damage from lumbar punctures performed with 25-gauge Quincke and Whitacre needles].
    Reina MA; López A; Villanueva MC; De Andrés JA; Martín S
    Rev Esp Anestesiol Reanim; 2005 May; 52(5):267-75. PubMed ID: 15968905
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of spinal needle design, size, and penetration angle on dural puncture cerebral spinal fluid loss.
    O'Connor G; Gingrich R; Moffat M
    AANA J; 2007 Apr; 75(2):111-6. PubMed ID: 17471881
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An anatomic study of the effects of dural puncture with different spinal needles.
    Celleno D; Capogna G; Costantino P; Catalano P
    Reg Anesth; 1993; 18(4):218-21. PubMed ID: 8398954
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dura-arachnoid lesions produced by 22 gauge Quincke spinal needles during a lumbar puncture.
    Reina MA; López A; Badorrey V; De Andrés JA; Martín S
    J Neurol Neurosurg Psychiatry; 2004 Jun; 75(6):893-7. PubMed ID: 15146008
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fluid flow through dural puncture sites. An in vitro comparison of needle point types.
    Cruickshank RH; Hopkinson JM
    Anaesthesia; 1989 May; 44(5):415-8. PubMed ID: 2742103
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A microscopic analysis of cut-bevel versus pencil-point spinal needles.
    Parker RK; White PF
    Anesth Analg; 1997 Nov; 85(5):1101-4. PubMed ID: 9356107
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of postanesthetic sequelae after clinical use of 27-gauge cutting and noncutting spinal needles.
    Puolakka R; Jokinen M; Pitkänen MT; Rosenberg PH
    Reg Anesth; 1997; 22(6):521-6. PubMed ID: 9425967
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Incidence of headache following intradural anesthesia with 26 gauge needles depending on whether the punction is done with the bevel perpendicular or parallel to the dura mater fibers].
    Casagrán B; Busquets A; Brull J
    Rev Esp Anestesiol Reanim; 1992; 39(4):227-9. PubMed ID: 1513939
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Subdural intra-arachnoid spread of local anesthetics. A complication of spinal anesthesia].
    Möllmann M; Holst D; Enk D; Lübbesmeyer H; Deitmer T; Lawin P
    Anaesthesist; 1992 Nov; 41(11):685-8. PubMed ID: 1463156
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of 25-gauge, Quincke and Whitacre needles for postdural puncture headache in obstetric patients.
    Bano F; Haider S; Aftab S; Sultan ST
    J Coll Physicians Surg Pak; 2004 Nov; 14(11):647-50. PubMed ID: 15530271
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Incidence of tissue coring with the 25-gauge Quincke and Whitacre spinal needles.
    Campbell DC; Douglas MJ; Taylor G
    Reg Anesth; 1996; 21(6):582-5. PubMed ID: 8956397
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Blood patch rates after lumbar puncture with Whitacre versus Quincke 22- and 20-gauge spinal needles.
    Hatfield MK; Handrich SJ; Willis JA; Beres RA; Zaleski GX
    AJR Am J Roentgenol; 2008 Jun; 190(6):1686-9. PubMed ID: 18492925
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Comparison of two 27-G-caliber needles for spinal anesthesia. Study of 1,555 patients].
    de Diego Fernández R; Tisner Madrid ML; Cabrerizo Torrente P; Sanjoaquín Mur T
    Rev Esp Anestesiol Reanim; 2003 Apr; 50(4):182-7. PubMed ID: 12825306
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative flow rates of saline in commonly used spinal needles including pencil-tip needles.
    Abouleish E; Mitchell M; Taylor G; Miller H; Warters D; Rashad MN
    Reg Anesth; 1994; 19(1):34-42. PubMed ID: 8148292
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.