These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

58 related articles for article (PubMed ID: 2782662)

  • 1. Oral reinforced endotracheal tube crushed and perforated from biting.
    Hoffmann CO; Swanson GA
    Anesth Analg; 1989 Oct; 69(4):552-3. PubMed ID: 2782662
    [No Abstract]   [Full Text] [Related]  

  • 2. Tube-in-tube rescue airway management for a perforated endotracheal tube by patient biting.
    Xue FS; Liao X; Liu JH; Zhang YM
    Anesthesiology; 2010 Jun; 112(6):1536-7. PubMed ID: 20502121
    [No Abstract]   [Full Text] [Related]  

  • 3. [Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia].
    Tose R; Kubota T; Hirota K; Sakai T; Ishihara H; Matsuki A
    Masui; 2003 Nov; 52(11):1218-20. PubMed ID: 14661571
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hazard associated with the reinforced endotracheal tube.
    Colbert ST; Moriarty DC
    Eur J Anaesthesiol; 1999 Mar; 16(3):206-7. PubMed ID: 10225174
    [No Abstract]   [Full Text] [Related]  

  • 5. The Parker Flex-Tip tracheal tube makes endotracheal intubation with the Bullard laryngoscope easier and faster.
    Suzuki A; Tampo A; Abe N; Otomo S; Minami S; Henderson JJ; Iwasaki H
    Eur J Anaesthesiol; 2008 Jan; 25(1):43-7. PubMed ID: 17666155
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Down syndrome: analysis of airway size and a guide for appropriate intubation.
    Shott SR
    Laryngoscope; 2000 Apr; 110(4):585-92. PubMed ID: 10764002
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Locating the site of resistance to the endotracheal tube in fiberoptic oral intubation and maneuvers to overcome it: a mannequin simulation study].
    Obón Monforte H; Romagosa Valls A; Trujillano Cabello J; González Enguita R; Guerrero de la Rotta LF; Sistac Ballarín JM
    Rev Esp Anestesiol Reanim; 2007 Dec; 54(10):584-90. PubMed ID: 18200992
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of standard polyvinyl chloride tracheal tubes and straight reinforced tracheal tubes for tracheal intubation through different sizes of the Airtraq laryngoscope in anesthetized and paralyzed patients: a randomized prospective study.
    Dimitriou VK; Zogogiannis ID; Douma AK; Pentilas ND; Liotiri DG; Wachtel MS; Karakitsos D
    Anesthesiology; 2009 Dec; 111(6):1265-70. PubMed ID: 19934870
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison of the Combitube with the endotracheal tube in cardiopulmonary resuscitation in the prehospital phase].
    Staudinger T; Brugger S; Röggla M; Rintelen C; Atherton GL; Johnson JC; Frass M
    Wien Klin Wochenschr; 1994; 106(13):412-5. PubMed ID: 8091765
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Management of pilot balloon assembly malfunction in an armored endotracheal tube in a child.
    ; Panda NB; Rajeev S
    Paediatr Anaesth; 2008 Apr; 18(4):356-7. PubMed ID: 18315663
    [No Abstract]   [Full Text] [Related]  

  • 11. Evaluation of two methods used to stabilize oral endotracheal tubes.
    Tasota FJ; Hoffman LA; Zullo TG; Jamison G
    Heart Lung; 1987 Mar; 16(2):140-6. PubMed ID: 3643914
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of a silicone wire-reinforced tube with the Parker and polyvinyl chloride tubes for tracheal intubation through an intubating laryngeal mask airway in patients with normal airways undergoing general anesthesia.
    Kanazi GE; El-Khatib M; Nasr VG; Kaddoum R; Al-Alami A; Baraka AS; Ayoub CM
    Anesth Analg; 2008 Sep; 107(3):994-7. PubMed ID: 18713919
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot study.
    Poelaert J; Depuydt P; De Wolf A; Van de Velde S; Herck I; Blot S
    J Thorac Cardiovasc Surg; 2008 Apr; 135(4):771-6. PubMed ID: 18374755
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction.
    Rao GS; Ali Z; Ramkiran S; Chandrasekhar HS
    Anesth Analg; 2006 Dec; 103(6):1624-5. PubMed ID: 17122294
    [No Abstract]   [Full Text] [Related]  

  • 15. Pediatric endotracheal tube selection: a comparison of age-based and height-based criteria.
    Davis D; Barbee L; Ririe D
    AANA J; 1998 Jun; 66(3):299-303. PubMed ID: 9830856
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pediatric endotracheal tube management: a new method of tube stabilization.
    Valley RD; Norfleet EA
    CCQ; 1985 Jun; 8(1):31-4. PubMed ID: 10271315
    [No Abstract]   [Full Text] [Related]  

  • 17. [A newly devised endotracheal tube for patients with narrowed trachea].
    Nishijima Y; Takahashi H; Taguchi N; Naito H
    Masui; 1993 Mar; 42(3):455-7. PubMed ID: 8468795
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endotracheal tube holder.
    Arrott JJ; Talley AW
    Anesth Analg; 1974; 53(1):70-1. PubMed ID: 4855714
    [No Abstract]   [Full Text] [Related]  

  • 19. [The endotracheal tube used during artificial pulmonary ventilation].
    Tulepov AS
    Anesteziol Reanimatol; 1998; (4):58-60. PubMed ID: 9770824
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new pediatric endotracheal tube.
    Ring WH; Adair JC; Elwyn RA
    Anesth Analg; 1975; 54(2):273-4. PubMed ID: 1168437
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.