These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 27851878)

  • 1. Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy.
    Oeltzschner G; Puts NA; Chan KL; Boer VO; Barker PB; Edden RA
    Magn Reson Med; 2017 Jan; 77(1):16-22. PubMed ID: 27851878
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hadamard editing of glutathione and macromolecule-suppressed GABA.
    Oeltzschner G; Chan KL; Saleh MG; Mikkelsen M; Puts NA; Edden RAE
    NMR Biomed; 2018 Jan; 31(1):. PubMed ID: 29073732
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simultaneous edited MRS of GABA and glutathione.
    Saleh MG; Oeltzschner G; Chan KL; Puts NAJ; Mikkelsen M; Schär M; Harris AD; Edden RAE
    Neuroimage; 2016 Nov; 142():576-582. PubMed ID: 27534734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous editing of GABA and glutathione at 7T using semi-LASER localization.
    Saleh MG; Mikkelsen M; Oeltzschner G; Chan KL; Berrington A; Barker PB; Edden RAE
    Magn Reson Med; 2018 Aug; 80(2):474-479. PubMed ID: 29285783
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spatial Hadamard encoding of J-edited spectroscopy using slice-selective editing pulses.
    Chan KL; Oeltzschner G; Schär M; Barker PB; Edden RA
    NMR Biomed; 2017 May; 30(5):. PubMed ID: 28128481
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An evaluation of the reproducibility of
    Prisciandaro JJ; Mikkelsen M; Saleh MG; Edden RAE
    Magn Reson Imaging; 2020 Jan; 65():109-113. PubMed ID: 31707293
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantification of GABA, glutamate and glutamine in a single measurement at 3 T using GABA-edited MEGA-PRESS.
    Sanaei Nezhad F; Anton A; Michou E; Jung J; Parkes LM; Williams SR
    NMR Biomed; 2018 Jan; 31(1):. PubMed ID: 29130590
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous detection of glutathione and lactate using spectral editing at 3 T.
    Chan KL; Snoussi K; Edden RAE; Barker PB
    NMR Biomed; 2017 Dec; 30(12):. PubMed ID: 28940608
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simultaneous edited MRS of GABA, glutathione, and ethanol.
    Saleh MG; Wang M; Mikkelsen M; Hui SCN; Oeltzschner G; Boissoneault J; Stennett B; Edden RAE; Porges EC
    NMR Biomed; 2020 Apr; 33(4):e4227. PubMed ID: 31943424
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo Glx and Glu measurements from GABA-edited MRS at 3 T.
    Bell T; Boudes ES; Loo RS; Barker GJ; Lythgoe DJ; Edden RAE; Lebel RM; Wilson M; Harris AD
    NMR Biomed; 2021 May; 34(5):e4245. PubMed ID: 31990112
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multi-vendor standardized sequence for edited magnetic resonance spectroscopy.
    Saleh MG; Rimbault D; Mikkelsen M; Oeltzschner G; Wang AM; Jiang D; Alhamud A; Near J; Schär M; Noeske R; Murdoch JB; Ersland L; Craven AR; Dwyer GE; Grüner ER; Pan L; Ahn S; Edden RAE
    Neuroimage; 2019 Apr; 189():425-431. PubMed ID: 30682536
    [TBL] [Abstract][Full Text] [Related]  

  • 12. GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence.
    Gu M; Hurd R; Noeske R; Baltusis L; Hancock R; Sacchet MD; Gotlib IH; Chin FT; Spielman DM
    Magn Reson Med; 2018 Jan; 79(1):41-47. PubMed ID: 28370458
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous editing of GABA and GSH with Hadamard-encoded MR spectroscopic imaging.
    Chan KL; Oeltzschner G; Saleh MG; Edden RAE; Barker PB
    Magn Reson Med; 2019 Jul; 82(1):21-32. PubMed ID: 30793803
    [TBL] [Abstract][Full Text] [Related]  

  • 14. J-difference-edited MRS measures of γ-aminobutyric acid before and after acute caffeine administration.
    Oeltzschner G; Zöllner HJ; Jonuscheit M; Lanzman RS; Schnitzler A; Wittsack HJ
    Magn Reson Med; 2018 Dec; 80(6):2356-2365. PubMed ID: 29752742
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Difference optimization: Automatic correction of relative frequency and phase for mean non-edited and edited GABA
    Cleve M; Krämer M; Gussew A; Reichenbach JR
    J Magn Reson; 2017 Jun; 279():16-21. PubMed ID: 28431306
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of acquisition and modeling parameters on the test-retest reproducibility of edited GABA.
    Hupfeld KE; Zöllner HJ; Hui SCN; Song Y; Murali-Manohar S; Yedavalli V; Oeltzschner G; Prisciandaro JJ; Edden RAE
    NMR Biomed; 2024 Apr; 37(4):e5076. PubMed ID: 38091628
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Estimating glutamate and Glx from GABA-optimized MEGA-PRESS: Off-resonance but not difference spectra values correspond to PRESS values.
    Maddock RJ; Caton MD; Ragland JD
    Psychiatry Res Neuroimaging; 2018 Sep; 279():22-30. PubMed ID: 30081290
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Whole-slice mapping of GABA and GABA
    Moser P; Hingerl L; Strasser B; Považan M; Hangel G; Andronesi OC; van der Kouwe A; Gruber S; Trattnig S; Bogner W
    Neuroimage; 2019 Jan; 184():475-489. PubMed ID: 30243974
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 3D GABA imaging with real-time motion correction, shim update and reacquisition of adiabatic spiral MRSI.
    Bogner W; Gagoski B; Hess AT; Bhat H; Tisdall MD; van der Kouwe AJW; Strasser B; Marjańska M; Trattnig S; Grant E; Rosen B; Andronesi OC
    Neuroimage; 2014 Dec; 103():290-302. PubMed ID: 25255945
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Glutamate measurements using edited MRS.
    Saleh MG; Prescot A; Chang L; Cloak C; Cunningham E; Subramaniam P; Renshaw PF; Yurgelun-Todd D; Zöllner HJ; Roberts TPL; Edden RAE; Ernst T
    Magn Reson Med; 2024 Apr; 91(4):1314-1322. PubMed ID: 38044723
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.