These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

433 related articles for article (PubMed ID: 27856487)

  • 21. A comparison of the fully repositionable and retrievable Boston Lotus and direct flow medical valves for the treatment of severe aortic stenosis: A single center experience.
    Giannini F; Latib A; Montorfano M; Ruparelia N; Romano V; Longoni M; Ferri L; Jabbour R; Mangieri A; Regazzoli D; Ancona M; Buzzatti N; Azzalini L; Tanaka A; Agricola E; Chieffo A; Alfieri O; Colombo A
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):966-974. PubMed ID: 28941127
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Edwards SAPIEN Versus Medtronic Aortic Bioprosthesis in Women Undergoing Transcatheter Aortic Valve Implantation (from the Win-TAVI Registry).
    Giannini C; Petronio AS; Mehilli J; Sartori S; Chandrasekhar J; Faggioni M; Lefèvre T; Presbitero P; Capranzano P; Tchetche D; Iadanza A; Sardella G; Van Mieghem NM; Meliga E; Dumonteil N; Fraccaro C; Trabattoni D; Mikhail GW; Ferrer MC; Naber C; Kievit P; Sorrentino S; Morice MC; Chieffo A; Mehran R;
    Am J Cardiol; 2020 Feb; 125(3):441-448. PubMed ID: 31813530
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Association of Paravalvular Regurgitation With 1-Year Outcomes After Transcatheter Aortic Valve Replacement With the SAPIEN 3 Valve.
    Pibarot P; Hahn RT; Weissman NJ; Arsenault M; Beaudoin J; Bernier M; Dahou A; Khalique OK; Asch FM; Toubal O; Leipsic J; Blanke P; Zhang F; Parvataneni R; Alu M; Herrmann H; Makkar R; Mack M; Smalling R; Leon M; Thourani VH; Kodali S
    JAMA Cardiol; 2017 Nov; 2(11):1208-1216. PubMed ID: 28973091
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Differences in Frame Geometry Between Balloon-expandable and Self-expanding Transcatheter Heart Valves and Association With Aortic Regurgitation.
    Rodríguez-Olivares R; Rahhab Z; Faquir NE; Ren B; Geleijnse M; Bruining N; van Mieghem NM; Schultz C; Lauritsch G; de Jaegere PP
    Rev Esp Cardiol (Engl Ed); 2016 Apr; 69(4):392-400. PubMed ID: 26643771
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Impact of Different Iterations of Devices and Degree of Aortic Valve Calcium on Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation.
    Kong WK; van Rosendael PJ; van der Kley F; de Weger A; Kamperidis V; Regeer MV; Marsan NA; Bax JJ; Delgado V
    Am J Cardiol; 2016 Aug; 118(4):567-71. PubMed ID: 27328953
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis.
    Jatene T; Castro-Filho A; Meneguz-Moreno RA; Siqueira DA; Abizaid AAC; Ramos AIO; Arrais M; Le Bihan DCS; Barretto RBM; Moreira AC; Sousa AGMR; Eduardo Sousa J
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):139-146. PubMed ID: 28029207
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Transaortic transcatheter aortic valve implantation: Results of the Polish arm of the ROUTE registry.
    Jagielak D; Bramlage P; Pawlaczyk R; Brzeziński M; Fijałkowski M; Łaskawski G; Ciećwierz D; Rogowski J; Kozaryn R
    Cardiol J; 2015; 22(6):651-6. PubMed ID: 26202653
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Contemporary transcatheter aortic valve replacement with third-generation balloon-expandable versus self-expanding devices.
    Rogers T; Steinvil A; Buchanan K; Alraies MC; Koifman E; Gai J; Torguson R; Okubagzi P; Ben-Dor I; Pichard A; Satler L; Waksman R
    J Interv Cardiol; 2017 Aug; 30(4):356-361. PubMed ID: 28493389
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Efficacy and safety of the Lotus Valve System for treatment of patients with severe aortic valve stenosis and intermediate surgical risk: Results from the Nordic Lotus-TAVR registry.
    De Backer O; Götberg M; Ihlberg L; Packer E; Savontaus M; Nielsen NE; Jørgensen TH; Nykänen A; Baranowski J; Niemelä M; Eskola M; Bjursten H; Søndergaard L
    Int J Cardiol; 2016 Sep; 219():92-7. PubMed ID: 27288972
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry.
    Romano M; Frank D; Cocchieri R; Jagielak D; Bonaros N; Aiello M; Lapeze J; Laine M; Chocron S; Muir D; Eichinger W; Thielmann M; Labrousse L; Arne Rein K; Verhoye JP; Gerosa G; Baumbach H; Deutsch C; Bramlage P; Thoenes M; Bapat V
    Interact Cardiovasc Thorac Surg; 2017 Nov; 25(5):757-764. PubMed ID: 28582580
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of latest generation transfemoral self-expandable and balloon-expandable transcatheter heart valves.
    Schaefer A; Linder M; Seiffert M; Schoen G; Deuschl F; Schofer N; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L
    Interact Cardiovasc Thorac Surg; 2017 Dec; 25(6):905-911. PubMed ID: 28655156
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A Randomized Evaluation of the SAPIEN XT Transcatheter Heart Valve System in Patients With Aortic Stenosis Who Are Not Candidates for Surgery.
    Webb JG; Doshi D; Mack MJ; Makkar R; Smith CR; Pichard AD; Kodali S; Kapadia S; Miller DC; Babaliaros V; Thourani V; Herrmann HC; Bodenhamer M; Whisenant BK; Ramee S; Maniar H; Kereiakes D; Xu K; Jaber WA; Menon V; Tuzcu EM; Wood D; Svensson LG; Leon MB
    JACC Cardiovasc Interv; 2015 Dec; 8(14):1797-806. PubMed ID: 26718510
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic CoreValve Revalving system devices: a multicenter collaborative study: the PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration).
    Chieffo A; Buchanan GL; Van Mieghem NM; Tchetche D; Dumonteil N; Latib A; van der Boon RM; Vahdat O; Marcheix B; Farah B; Serruys PW; Fajadet J; Carrié D; de Jaegere PP; Colombo A
    J Am Coll Cardiol; 2013 Feb; 61(8):830-6. PubMed ID: 23333140
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance.
    Del Trigo M; Dahou A; Webb JG; Dvir D; Puri R; Abdul-Jawad Altisent O; Campelo-Parada F; Thompson C; Leipsic J; Stub D; DeLarochellière R; Paradis JM; Dumont E; Doyle D; Mohammadi S; Pasian S; Côté M; Pibarot P; Rodés-Cabau J
    Rev Esp Cardiol (Engl Ed); 2016 May; 69(5):501-8. PubMed ID: 26739827
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Transfemoral valve-in-valve implantation for degenerated bioprosthetic aortic valves using the new balloon-expandable Edwards Sapien 3 valve.
    Gonska B; Seeger J; Rodewald C; Scharnbeck D; Rottbauer W; Wöhrle J
    Catheter Cardiovasc Interv; 2016 Oct; 88(4):636-643. PubMed ID: 27142354
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Balloon-Expandable Transcatheter Heart Valve: A Single-Center Experience.
    Husser O; Pellegrini C; Kessler T; Burgdorf C; Thaller H; Mayr NP; Ott I; Kasel AM; Schunkert H; Kastrati A; Hengstenberg C
    JACC Cardiovasc Interv; 2015 Dec; 8(14):1809-16. PubMed ID: 26718512
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pacemaker Implantation After Balloon- or Self-Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis.
    Bisson A; Bodin A; Herbert J; Lacour T; Saint Etienne C; Pierre B; Clementy N; Deharo P; Babuty D; Fauchier L
    J Am Heart Assoc; 2020 May; 9(9):e015896. PubMed ID: 32362220
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of Edwards Sapien XT versus Lotus Valve Devices in Terms of Electrophysiological Study Parameters in Patients Undergoing TAVI.
    Eksik A; Yildirim A; Gul M; Aslan S; Tosu AR; Surgit O; Cakmak HA; Satilmisoglu MH; Akkaya E; Bakir I
    Pacing Clin Electrophysiol; 2016 Oct; 39(10):1132-1140. PubMed ID: 27418419
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 22.