These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 27860359)

  • 1. Spectral diffuse reflectance and autofluorescence imaging can perform early prediction of blood vessel occlusion in skin flaps.
    Chen S; Zhu C; Hoe-Kong Chui C; Sheoran G; Tan BK; Liu Q
    J Biophotonics; 2017 Dec; 10(12):1665-1675. PubMed ID: 27860359
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Early detection and differentiation of venous and arterial occlusion in skin flaps using visible diffuse reflectance spectroscopy and autofluorescence spectroscopy.
    Zhu C; Chen S; Chui CH; Tan BK; Liu Q
    Biomed Opt Express; 2016 Feb; 7(2):570-80. PubMed ID: 26977363
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early prediction of skin viability using visible diffuse reflectance spectroscopy and autofluorescence spectroscopy.
    Zhu C; Chen S; Chui CH; Tan BK; Liu Q
    Plast Reconstr Surg; 2014 Aug; 134(2):240e-247e. PubMed ID: 25068346
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reliable assessment of skin flap viability using orthogonal polarization imaging.
    Olivier WA; Hazen A; Levine JP; Soltanian H; Chung S; Gurtner GC
    Plast Reconstr Surg; 2003 Aug; 112(2):547-55. PubMed ID: 12900613
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Postoperative quantitative assessment of reconstructive tissue status in a cutaneous flap model using spatial frequency domain imaging.
    Yafi A; Vetter TS; Scholz T; Patel S; Saager RB; Cuccia DJ; Evans GR; Durkin AJ
    Plast Reconstr Surg; 2011 Jan; 127(1):117-130. PubMed ID: 21200206
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of skin flaps using optically based methods for measuring blood flow and oxygenation.
    Payette JR; Kohlenberg E; Leonardi L; Pabbies A; Kerr P; Liu KZ; Sowa MG
    Plast Reconstr Surg; 2005 Feb; 115(2):539-46. PubMed ID: 15692360
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of flap venous and arterial occlusion using interstitial glucose monitoring in a rodent model.
    Sitzman TJ; Hanson SE; King TW; Gutowski KA
    Plast Reconstr Surg; 2010 Jul; 126(1):71-79. PubMed ID: 20595858
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Examination of tissue oxygen saturation (StO2) changes associated with vascular pedicle occlusion in a rat Island flap model using near-Infrared spectroscopy.
    Kagaya Y; Ohura N; Kurita M; Takushima A; Harii K
    Microsurgery; 2015 Jul; 35(5):393-8. PubMed ID: 25639265
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Early detection of complete vascular occlusion in a pedicle flap model using quantitative [corrected] spectral imaging.
    Pharaon MR; Scholz T; Bogdanoff S; Cuccia D; Durkin AJ; Hoyt DB; Evans GRD
    Plast Reconstr Surg; 2010 Dec; 126(6):1924-1935. PubMed ID: 21124132
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tissue glucose and lactate following vascular occlusion in island skin flaps.
    Su CT; Im MJ; Hoopes JE
    Plast Reconstr Surg; 1982 Aug; 70(2):202-5. PubMed ID: 7048369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of postoperative vessel occlusion on the viability of free microvascular skin-fat flaps and island flaps in rats.
    Oswald P; Tilgner A; Schumann D
    J Reconstr Microsurg; 1988 Oct; 4(5):403-7. PubMed ID: 2462047
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of sequence, timing of vascular anastomosis, and clamp removal on survival of microsurgical flaps.
    Zhang F; Pang Y; Buntic R; Jones M; Cai Z; Buncke HJ; Lineaweaver WC
    J Reconstr Microsurg; 2002 Nov; 18(8):697-702. PubMed ID: 12524589
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of three different supercharging procedures in a rat skin flap model.
    Chang H; Nobuaki I; Minabe T; Nakajima H
    Plast Reconstr Surg; 2004 Jan; 113(1):277-83. PubMed ID: 14707647
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patterns of flap loss related to arterial and venous insufficiency in the rat pedicled TRAM flap.
    Qiao Q; Moon W; Zhang F; Chen SG; Kunda L; Lineaweaver WC; Buncke HJ
    Ann Plast Surg; 1999 Aug; 43(2):167-71. PubMed ID: 10454324
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Proinflammatory cytokines gene expression in skin flaps with arterial and venous ischemia in rats.
    Zhang F; Hu EC; Topp S; Lei M; Chen W; Lineaweaver WC
    J Reconstr Microsurg; 2006 Nov; 22(8):641-7. PubMed ID: 17136677
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Polydeoxyribonucleotide restores blood flow in an experimental model of ischemic skin flaps.
    Polito F; Bitto A; Galeano M; Irrera N; Marini H; Calò M; Squadrito F; Altavilla D
    J Vasc Surg; 2012 Feb; 55(2):479-88. PubMed ID: 22051873
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A study of blood flow dynamics in flap delay using the full-field laser perfusion imager.
    Du Z; Zan T; Li H; Li Q
    Microvasc Res; 2011 Nov; 82(3):284-90. PubMed ID: 22001187
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessing flap perfusion: optical spectroscopy versus venous doppler ultrasonography.
    McKenna J; Pabbies A; Friesen JR; Sowa MG; Hayakawa T; Kerr PD
    J Otolaryngol Head Neck Surg; 2009 Oct; 38(5):587-94. PubMed ID: 19769831
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Myocutaneous flap failure: early detection with Gd-DTPA-enhanced MR imaging.
    Varnell RM; Flint PW; Dalley RW; Maravilla KR; Cummings CW; Shuman WP
    Radiology; 1989 Dec; 173(3):755-8. PubMed ID: 2813782
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery.
    Thorniley MS; Sinclair JS; Barnett NJ; Shurey CB; Green CJ
    Br J Plast Surg; 1998 Apr; 51(3):218-26. PubMed ID: 9664881
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.