BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 27862223)

  • 1. Effects of hip implant modular neck material and assembly method on fatigue life and distraction force.
    Aljenaei F; Catelas I; Louati H; Beaulé PE; Nganbe M
    J Orthop Res; 2017 Sep; 35(9):2023-2030. PubMed ID: 27862223
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements.
    Nganbe M; Khan U; Louati H; Speirs A; Beaulé PE
    J Biomed Mater Res B Appl Biomater; 2011 Apr; 97(1):132-8. PubMed ID: 21290591
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: An in vitro study.
    Panagiotidou A; Cobb T; Meswania J; Skinner J; Hart A; Haddad F; Blunn G
    J Orthop Res; 2018 Jan; 36(1):405-416. PubMed ID: 28485507
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assembly force and taper angle difference influence the relative motion at the stem-neck interface of bi-modular hip prostheses.
    Haschke H; Jauch-Matt SY; Sellenschloh K; Huber G; Morlock MM
    Proc Inst Mech Eng H; 2016 Jul; 230(7):690-9. PubMed ID: 27170535
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Retrieval analysis and in vitro assessment of strength, durability, and distraction of a modular total hip replacement.
    Nganbe M; Louati H; Khan U; Speirs A; Beaulé PE
    J Biomed Mater Res A; 2010 Dec; 95(3):819-27. PubMed ID: 20737432
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation.
    Royhman D; Patel M; Runa MJ; Wimmer MA; Jacobs JJ; Hallab NJ; Mathew MT
    J Mech Behav Biomed Mater; 2016 Sep; 62():570-587. PubMed ID: 27310572
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Why do some titanium-alloy total hip arthroplasty modular necks fail?
    Fokter SK; Moličnik A; Kavalar R; Pelicon P; Rudolf R; Gubeljak N
    J Mech Behav Biomed Mater; 2017 May; 69():107-114. PubMed ID: 28064103
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion behavior of tantalum-coated cobalt-chromium modular necks compared to titanium modular necks in a simulator test.
    Dorn U; Neumann D; Frank M
    J Arthroplasty; 2014 Apr; 29(4):831-5. PubMed ID: 24099841
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements.
    Hall DJ; Pourzal R; Lundberg HJ; Mathew MT; Jacobs JJ; Urban RM
    J Biomed Mater Res B Appl Biomater; 2018 Jul; 106(5):1672-1685. PubMed ID: 28842959
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fretting corrosion of CoCrMo and Ti6Al4V interfaces.
    Swaminathan V; Gilbert JL
    Biomaterials; 2012 Aug; 33(22):5487-503. PubMed ID: 22575833
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fretting corrosion of Si
    Khullar P; Zhu D; Gilbert JL
    J Orthop Res; 2020 Jul; 38(7):1617-1626. PubMed ID: 32249959
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The electrochemical and mechanical behavior of passivated and TiN/AlN-coated CoCrMo and Ti6Al4V alloys.
    Goldberg JR; Gilbert JL
    Biomaterials; 2004 Feb; 25(5):851-64. PubMed ID: 14609674
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.
    Jauch SY; Coles LG; Ng LV; Miles AW; Gill HS
    Med Eng Phys; 2014 Sep; 36(9):1140-6. PubMed ID: 25051900
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of Seating Load Magnitude on Incremental Cyclic Fretting Corrosion in 5°40' Mixed Alloy Modular Taper Junctions.
    Pierre D; Swaminathan V; Scholl LY; TenHuisen K; Gilbert JL
    J Arthroplasty; 2018 Jun; 33(6):1953-1961. PubMed ID: 29486910
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Micromotions at the taper interface between stem and neck adapter of a bimodular hip prosthesis during activities of daily living.
    Jauch SY; Huber G; Sellenschloh K; Haschke H; Baxmann M; Grupp TM; Morlock MM
    J Orthop Res; 2013 Aug; 31(8):1165-71. PubMed ID: 23553890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of the support systems' compliance on total hip modular taper seating stability.
    Scholl L; Pierre D; Rajaravivarma R; Lee R; Faizan A; Swaminathan V; TenHuisen K; Gilbert JL; Nevelos J
    Proc Inst Mech Eng H; 2018 Sep; 232(9):862-870. PubMed ID: 30238861
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of impact assembly on the fretting corrosion of modular hip tapers.
    Mroczkowski ML; Hertzler JS; Humphrey SM; Johnson T; Blanchard CR
    J Orthop Res; 2006 Feb; 24(2):271-9. PubMed ID: 16435360
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis.
    Jauch SY; Huber G; Hoenig E; Baxmann M; Grupp TM; Morlock MM
    J Biomech; 2011 Jun; 44(9):1747-51. PubMed ID: 21531416
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The proximal modular neck in THA: a bridge too far: affirms.
    Dunbar MJ
    Orthopedics; 2010 Sep; 33(9):640. PubMed ID: 20839691
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro test methods for seating and fretting corrosion behavior of modular metal-on-metal acetabular tapers.
    Shenoy AA; Gilbert JL
    J Orthop Res; 2020 May; 38(5):1089-1100. PubMed ID: 31803946
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.